← All vessels
SILVER BULLET
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named SILVER BULLET
SILVER BULLET is a 2008 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2009, most recently in November 2025, along with 21 deficiencies and 2 operational controls.
Records from 2009 to 2025. Most recent: inspection, 17 November 2025.
- Built
- 2008
- Last inspected
- 17 November 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 21 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded1
Years with a record
15 calendar years (2009–2025)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it3 - Simplified, Gross Ton
3 - Simplified, Net Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
17 November 2025
Administrative Inspection · Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8269761
29 October 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8012399
4 October 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7791775
6 October 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7573014
24 September 2021
COI Inspection · Hull Examination · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7319811
1 October 2020
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7065291
24 September 2019
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6815255
27 September 2018
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6549486
6 July 2018
Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6464536
28 September 2017
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6276863
13 September 2016
COI Inspection · Drydock Exam · Internal Structural Exam · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5999037
13 September 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6012166
2 June 2014
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4877543
14 June 2012
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4350265
15 September 2011
Plan Review "T" Boat
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4146257
11 February 2010
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3678674
5 May 2009
Construction Oversight · Simplified Stability Test · Initial Certification · Plan Review "T" Boat
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3122863
24 April 2009
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3461815
20 February 2009
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3421042
19 February 2009
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3420456
Deficiency record · 21
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 December 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck.
The location of the vessel's fuel shutoff valve is impracticable to reach in an emergency where fuel would need to be stopped in the event of an engine fire.
Engineer a remote means to close the valve from the operators position.
46 CFR 182.455(b)(4)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 December 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container or compartment for life jackets.
Vessel did not have markings for the stowage location or number of child lifejackets onboard.
46 CFR 185.604(f)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 October 2022
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines.
Vessel's fuel shutoff valve was not mounted in a visible, fixed position, making it difficult to locate and operate quickly and properly.
Relocate and mount fuel shutoff valve closer to operator's station in a fixed position.
46 CFR 182.455(a)(4)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2021
Resolved
An adult life jacket must be provided for each person carried on board the vessel.
MI noticed only 14 adult and 1 child life jackets were in serviceable condition and properly labeled.
46 CFR 180.71 (a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2021
Resolved
Every portable fire extinguisher must be supplied with a suitable bracket which will hold the extinguisher securely in its stowage location.
MI noticed that forward fire extinguisher bracket was too small for current fire extinguisher.
46 CFR 162.028-3 (c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 September 2021
Resolved
A submersible electric bilge pump may be used as a power bilge pump. The pump must be permanently mounted.
MI noticed the electric bilge pump was not permanently secured to the deck.
46 CFR 182.520 (e)(3)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 September 2021
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection.
Upon administrative review, found vessel's COI to be expired.
46 CFR 176.100(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2018
Resolved
Exhaust must not leak from piping or any connections. MI observed exhaust cracks by engine manifold. - 46CFR182.430(b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2018
Resolved
Minimize accidental personnel contact with energized parts. MI observed dead ended wire stemming from battery. - 46CFR183.115(c)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 September 2018
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. MI observed possible modifications to steering system. Owner/operator must prove steering system is in accordance with manufacturer specifications or repair/replace to manufacturer specifications. - 46CFR182.610(a)(1)
Engineering › Gasoline Engine (propulsion) › Ignition Wire (4 cycle)
Issued 13 September 2016
Resolved
Prove proper operation of main engine to the satisfaction of the marine inspector IAW 46 cfr 182.200a
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 September 2016
Resolved
Vessel's rails and courses are spaced at 12" intervals. Spacing of rails and courses on excursion vessels is required to be no greater than 4". Submit proposal for satisfying requirement to marine inspector IAW 46 CFR 177.900 (g) (1)
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 13 September 2016
Resolved
Vessel does not have the A-II fire extinguisher for the accommodation space as required by Table 181.500(a) of 46 CFR. Provide one A-II fire extinguisher for the accommodation space IAW 46 CFR 181.500
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 2 June 2014
Resolved
Prove proper operation of navigation lights prior to operations at night.
Engineering › Fuel Oil Service System › Piping
Issued 24 April 2009
Resolved
Vessel is restricted from carrying passengers until leaking fuel tank is repaired.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 February 2009
Resolved
Four adult PFD's require replacement of the retroreflective tape prior to the vessel operating.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 February 2009
Resolved
One adult PFD was found torn and unserviceable. Replacement required prior to operating.
Lifesaving › Lifebuoys › Stowage
Issued 19 February 2009
Resolved
Ring buoy shall be provided with UV resistant buoyant line and waterlight shall be properly secured using corrosion resistant clip prior to operating.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 19 February 2009
Resolved
Vessel is to repair fuel leak IWO sending unit on the fuel tank prior to operating.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 19 February 2009
Resolved
Fuel cut off valve is to be properly installed to facilitate proper closure and is to be properly labeled prior to operating.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 19 February 2009
Resolved
Fitting for fuel supply line located on the fuel storage tank is to be tightened to secure leaking prior to operating.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.