Records from 2016 to 2026. Most recent: inspection, 18 August 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)42.3 ft × 14.5 ft × 6.0 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESMAC CUSTOM BOATS INC · SURRY, ME, UNITED STATES · built 2008
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCUMBERLAND ISLAND, GA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
19 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
18 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
18 August 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8467107
16 July 2025
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8186677
6 December 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8045084
16 August 2024
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7984450
17 May 2023
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7690371
11 January 2023
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7617441
19 July 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7510756
20 October 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7337622
19 July 2021
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7256244
14 August 2020
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6999540
12 February 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6907961
8 August 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6774402
10 June 2019
Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6709153
21 May 2018
DAPI Audit · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6419439
30 March 2018
In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6381698
17 August 2017
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6243206
31 August 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5987835
17 August 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5975603
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 July 2021
Resolved
Floating watertight must be approved IAW subchapter Q.
Waterlight battery expired.
Vessel temporarily restricted to daylight operations.
Action required: 705 - Other - as specified
Due 19 August 2021
Resolved 20 July 2021
Resolution: Owner/operator provided proof of new battery installation in RLB WL.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 August 2019
Resolved
A vessel not required to have a driven fire pump must have at least three 2.5 gallon buckets, with lanyard, easily available during a emergency. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. Provided needed fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 16 August 2019
Resolution: [name withheld] completed Def. Check and witnessed fire buckets are now on board vessel.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 August 2019
Resolved
Drills conducted by crew were infrequent and not logged. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Log all training conducted.
Action required: 10 - Deficiency Rectified
Due 9 August 2019
Resolved 8 August 2019
Resolution: Master completed man over board and fire drills and logged them in ships log book.