← All vessels
VALLE AZZURRA
VALLE AZZURRA is a 2007 tank ship. The Coast Guard has recorded 31 inspections since 2008, most recently in May 2026, along with 10 deficiencies and 6 operational controls.
Records from 2008 to 2026. Most recent: inspection, 1 May 2026.
- Built
- 2007
- Last inspected
- 1 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9391488 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA4938
935541
Flag
MALTA
—
Maury page id
psix-935541
Inspections, by type
…with no type recorded6
Years with a record
13 calendar years (2008–2026)
The 31 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it29987 - Convention (Subpart B), Gross Ton
13240 - Convention (Subpart B), Net Ton
50633 - Dead Weight, Metric Ton
60643 - Displacement, Metric Ton
13240 - Convention (Subpart B), Net Ton
50633 - Dead Weight, Metric Ton
60643 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 31
1 May 2026
COC-CHEM & TVE Annual · Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8359131
23 March 2026
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8330376
25 April 2025
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8120048
13 January 2024
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7849139
10 January 2024
Deficiency Check · COE-Administrative
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7847435
23 September 2023
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7797013
19 April 2022
Administrative Inspection · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7434228
12 October 2021
PSC B · COC-CHEM Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7331024
7 January 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7121247
20 October 2020
PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7078989
8 January 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6885552
28 October 2019
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6843417
8 October 2019
Administrative Inspection · COC-CHEM & TVE Annual · Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6827641
31 May 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6699721
2 April 2019
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6653453
22 March 2019
COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6647275
26 November 2018
COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6584960
19 November 2018
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6583781
17 October 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6563053
5 October 2018
ISPS II Exam · COC-CHEM & TVE Renew · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6555885
12 May 2017
COE-Offshore · COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6144987
10 May 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6143181
28 March 2016
COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5840720
26 February 2010
COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3668677
4 April 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3177420
25 March 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3171188
21 February 2008
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3151213
14 January 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3130180
14 January 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3130474
11 January 2008
MARPOL Annex V Examination · COC-TVE Renew · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3124773
10 January 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3128702
Deficiency record · 10
14 - Pollution Prevention › 148 - Ballast Water › Ballast water exchange
Issued 19 April 2022
Resolved
Failure of master, owner, operator, agent, or person in charge of a vessel to employ one of the ballast water management methods provided for in this subpart. While vessel was in the port of Corpus Christi, PSCO determined that the vessel did not conduct a Ballast Water Exchange in accordance with 151.2025(a)(3) between Pajaritos, Mexico and Corpus Christi, TX. 151.2025(a)(3) requires vessels remaining subject to Ballast Water Exchange, with a BWTS extension, to conduct and exchange 200 NM from shore. 151.205 does not require the vessel to deviate from its intended voyage to conduct an exchange, yet still requires an exchange to be conducted in accordance with 151.2025(a)(3). According to the vessel's ballast water report, the vessel discharged approximately 3284 cubic meters of ballast water without conducting an exchange between Pajaritos, Mexico and Corpus Christi, TX.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 October 2021
Resolved
Each cargo tank of a tank ship must be equipped with an intrinsically safe high level alarm and a tank overfill alarm.
PSCO's obsesrved failure of high-level alarm panel preventing operation of all cargo tank high levels. Prior to conducting cargo operations, vessel needs to submit class approval for repair of high-level alarms.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 8 October 2019
Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the Organization.
PSCO observed electrical connection glands of 04 lights installed in hazardous area on cargo deck sealed with caulking due to deterioration of exterior coating. These lights no longer conform to IEC 60092-502:1999.
Secure circuits of these lights until repairs are made and classification society attests to the repairs.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 8 October 2019
Resolved
Compressed air breathing apparatus shall be fitted with an audible alarm and a visual or other device which will alert the user before the volume of the air in the cylinder has been reduced to no less than 200 L.
PSCO observed 02 chemical suit SCBAs and 02 fire suit SCBAs audible alarms were inoperable.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 October 2019
Resolved
Sufficient foam concentrate shall be supplied to ensure at least 30 min of foam generation.
Fixed deck foam gauge indicates 7.2 cubic meters (28 minutes) of foam concentrate within deck foam tank. As per fixed deck foam technical manual, 7.6 cubic meters (30 minutes) is required.
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 8 October 2019
Resolved
Such monitoring equipment (cargo tank pressure alarms) shall also provide an alarm facility which is activated by detection of over pressure and under pressure conditions within a tank.
When overheating or overcooling could result in a dangerous condition, an alarm system which monitors the cargo temperature shall be provided.
Pressure/temperature monitoring equipment alarm facility did not produce a sufficient audible alarm when pressure/temperature limits were exceeded.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 8 October 2019
Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment.
Above listed deficiencies, checklist provided for the crew do not stipulate appropriate testing or inspection intervals for critical firefighting systems. In particular, the fixed deck foam firefighting system is required to be visually inspected weekly as per technical manual, yet company policy states 3 months for inspection. Actual logs used onboard do not have level checks listed. The testing of SCBA alarms is different between company policy and checklist; no testing of SCBA alarms could be found. Regarding deficiency #4, the pressure alarms are required to be tested monthly. Last check was 06OCT2019. No non-conformity reports were filled out for inadequate audible alarms. An internal safety audit and corrective action is required within three months.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 1 February 2010
Resolved
Code: 1835 Stud in vessel's vapor connection flange is facing inwards. Stud is required to be projecting outward from the flange face. 70ac, 46CFR39.20-1(e)--see COC for restrictions imposed. Requires class report to rectify.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 14 January 2008
Resolved
Master informed agent that echo depth sounder is giving incorrect information. Vsl was issued inbound LOD. Due to adverse weather conditions divers were unable to to install new tranducer. Vessel was allowed to depart w/ the new tranducer on board & the requiremnet to have it replaced prior to next U.S. port to the satisfaction of the USCG.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 11 January 2008
Resolved
VRP required by 33CFR 155 not approved as required. Vessel cannot transport, store or transfer oil product in the U.S. without an approval letter or requesting a waiver from the applicable COTP zone.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.