Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it29987 - Convention (Subpart B), Gross Ton 13240 - Convention (Subpart B), Net Ton 50633 - Dead Weight, Metric Ton 60643 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 23 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 23
1 May 2026COC-CHEM & TVE Annual · Administrative Inspection
14 - Pollution Prevention › 148 - Ballast Water › Ballast water exchange
Issued 19 April 2022Resolved
Failure of master, owner, operator, agent, or person in charge of a vessel to employ one of the ballast water management methods provided for in this subpart. While vessel was in the port of Corpus Christi, PSCO determined that the vessel did not conduct a Ballast Water Exchange in accordance with 151.2025(a)(3) between Pajaritos, Mexico and Corpus Christi, TX. 151.2025(a)(3) requires vessels remaining subject to Ballast Water Exchange, with a BWTS extension, to conduct and exchange 200 NM from shore. 151.205 does not require the vessel to deviate from its intended voyage to conduct an exchange, yet still requires an exchange to be conducted in accordance with 151.2025(a)(3). According to the vessel's ballast water report, the vessel discharged approximately 3284 cubic meters of ballast water without conducting an exchange between Pajaritos, Mexico and Corpus Christi, TX.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 January 2024
Resolution: Vessel submitted proper ballast water report with treatment system and proper ballast water practices conducted.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 October 2021Resolved
Each cargo tank of a tank ship must be equipped with an intrinsically safe high level alarm and a tank overfill alarm.
PSCO's obsesrved failure of high-level alarm panel preventing operation of all cargo tank high levels. Prior to conducting cargo operations, vessel needs to submit class approval for repair of high-level alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2021
Resolved 15 October 2021
Resolution: Vessel submitted class report attesting to the deficiency being rectified, see attached report
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 8 October 2019Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the Organization.
PSCO observed electrical connection glands of 04 lights installed in hazardous area on cargo deck sealed with caulking due to deterioration of exterior coating. These lights no longer conform to IEC 60092-502:1999.
Secure circuits of these lights until repairs are made and classification society attests to the repairs.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2019
Resolved 10 October 2019
Resolution: Received class report attesting to satisfactory rectification.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 8 October 2019Resolved
Compressed air breathing apparatus shall be fitted with an audible alarm and a visual or other device which will alert the user before the volume of the air in the cylinder has been reduced to no less than 200 L.
PSCO observed 02 chemical suit SCBAs and 02 fire suit SCBAs audible alarms were inoperable.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2019
Resolved 10 October 2019
Resolution: Received class report attesting to satisfactory rectification.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 October 2019Resolved
Sufficient foam concentrate shall be supplied to ensure at least 30 min of foam generation.
Fixed deck foam gauge indicates 7.2 cubic meters (28 minutes) of foam concentrate within deck foam tank. As per fixed deck foam technical manual, 7.6 cubic meters (30 minutes) is required.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2019
Resolved 10 October 2019
Resolution: Received class report attesting to satisfactory rectification.
Such monitoring equipment (cargo tank pressure alarms) shall also provide an alarm facility which is activated by detection of over pressure and under pressure conditions within a tank.
When overheating or overcooling could result in a dangerous condition, an alarm system which monitors the cargo temperature shall be provided.
Pressure/temperature monitoring equipment alarm facility did not produce a sufficient audible alarm when pressure/temperature limits were exceeded.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 October 2019
Resolved 28 October 2019
Resolution: Verified audible alarm via high pressure alarm on cargo tank 4P.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 8 October 2019Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment.
Above listed deficiencies, checklist provided for the crew do not stipulate appropriate testing or inspection intervals for critical firefighting systems. In particular, the fixed deck foam firefighting system is required to be visually inspected weekly as per technical manual, yet company policy states 3 months for inspection. Actual logs used onboard do not have level checks listed. The testing of SCBA alarms is different between company policy and checklist; no testing of SCBA alarms could be found. Regarding deficiency #4, the pressure alarms are required to be tested monthly. Last check was 06OCT2019. No non-conformity reports were filled out for inadequate audible alarms. An internal safety audit and corrective action is required within three months.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 January 2020
Resolved 8 January 2020
Resolution: Recieved documentaion of an ISM audit from the operator.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.