MAURY USCG vessel records Sign in
← All vessels

SIENNA

SIENNA is a tank ship. The Coast Guard has recorded 16 inspections since 2008, most recently in March 2026, along with 5 deficiencies and 3 operational controls, 1 with no removal date recorded.

Records from 2008 to 2026. Most recent: inspection, 12 March 2026.

Built
Not recorded
Last inspected
12 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9336971 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
935692
Flag
LIBERIA
—
Maury page id
psix-935692

Inspections, by type

…with no type recorded4
Years with a record 11 calendar years (2008–2026)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it172646 - Displacement, Metric Ton
79235 - Convention (Subpart B), Gross Ton
47276 - Convention (Subpart B), Net Ton
149847 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

12 March 2026 PSC B · COE-Administrative · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8324444
12 November 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7823540
12 November 2023 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7823547
22 December 2022 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7609150
22 December 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7612456
14 December 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7609160
16 June 2021 PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7226953
3 December 2018 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6590486
9 August 2017 Deficiency Check · ISPS II Exam · Ballast Water Examination · Administrative Inspection · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6227139
18 April 2016 COC-TVE Renew · Ballast Water Examination · Administrative Inspection · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5855025
12 April 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5852915
28 March 2014 COC-TVE Renew · ISPS II Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4820142
29 March 2010 COC-TVE Renew · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3700200
5 February 2009 ISPS II Exam · Ballast Water Examination · COC-TVE Annual · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3399091
17 January 2008 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3131573
17 January 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3132153

Deficiency record · 5

Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 9 August 2017 Resolved
A second source of energy shall be provided for the emergency generator, for an additional three starts in 30 min. unless manual starting can be demonstrated effective. Hydraulic means of starting (2nd means) inoperable. Crew unable to demonstrate second source of energy for emergency generator.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 August 2017
Resolution: Received class report attesting to a fully operational second means of starting the emergency generator. See class report in documents.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 22 March 2010 Resolved
0610 - Lifeboat - Both port & stbd lifeboat batteries were incapable of sustaining a charge sufficient to facilitate starting. Safety mgmt system found satisfactory. Batteries could not be delivered because of U.S. Customs restrictions. - SOLAS III REG 20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2010
Resolution: Coast Guard witnessed satisfactory tests of port and stbd lifeboats. Deficiency cleared.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 January 2008 Resolved
STBD deck rail forward of STBD manifold bent due to prior lightering ops.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Resolution: recieved class report attesting no immediate repairs needed at time
Operations/Management › Drills/Instruction › Fire
Issued 17 January 2008 Resolved
during fire drill ventilation was not closed
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2008
Resolution: master counseled fire team on proper procedure for ventilation
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 17 January 2008 Resolved
vessel rquired to have one portable instrument for measuring flammable vapor content, vessel did not have portable instrument that worked properly.
Action required: 705 - Other - as specified
Due 24 January 2008
Resolved 18 January 2008
Resolution: recieved class report attesting to proper operation of portable gas detector

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.