MAURY USCG vessel records Sign in
← All vessels

OCEAN PRO 35

OCEAN PRO 35 is a 2008 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2008, most recently in November 2025, along with 28 deficiencies and 5 operational controls.

Records from 2008 to 2025. Most recent: inspection, 20 November 2025.

Built
2008
Last inspected
20 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4037
935963
Flag
UNITED STATES
367773770
Maury page id
psix-935963

Inspections, by type

Years with a record 15 calendar years (2008–2025)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)34.3 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CLERMONT, NJ, UNITED STATES · built 2008
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portAVALON, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4037MMSI 367773770 · active · compulsorily equipped · granted 18 February 2017, expires 18 February 2027
WDE4374MMSI 367352220 · expired · compulsorily equipped · granted 26 April 2008, cancelled 30 June 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 23

20 November 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8093577
3 February 2025 Hull Examination · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8069014
27 August 2024 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7979733
29 November 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7826077
26 January 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7590651
16 November 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7588430
10 June 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7221899
1 April 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7165467
5 January 2021 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7119643
18 December 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7113917
30 March 2020 Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6975134
4 September 2019 Deficiency Check · COI Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6750893
15 July 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6750790
3 April 2018 Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6384167
4 January 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6328052
18 February 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6093525
3 January 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6065374
1 March 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5812300
18 December 2015 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5784601
2 February 2012 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4237262
21 September 2011 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4151149
15 December 2010 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3901584
9 January 2008 Hull Examination · Construction Oversight · Initial Certification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3127409

Deficiency record · 28

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is overdue for drydock examination due January 31st, 2025. Vessel is to complete a satisfactory drydock examination prior to carrying passengers. 46 CFR 176.600 (c) (1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2025
Resolution: Vessel conducted satisfactory drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 August 2024 Resolved
Each vessel certificated to operate on a limited coastwise route within three miles of land in cold water must be provided with an inflatable buoyant apparatus (IBA) of an aggregate capacity that will accommodate at least 67% of the total number of persons permitted on board; or life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. IBA listed on COI was not on-board vessel, all equipment listed on COI is required to be on-board vessel when passengers are carried unless authorized by OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 16 September 2024
Resolution: LF serviced and installed on bow
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 August 2024 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessel carries less than 49 passengers and is between 26 and 65ft thus required to have 1 fixed powered pump and 1 portable hand pump. A portable hand bilge pump must be capable of pumping water, but not necessarily simultaneously, from all watertight compartments and provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard. Vessel did not have a portable bilge pump on-board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 16 September 2024
Resolution: Portable bilge pump provided
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 November 2023 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Fixed-gas fire extinguishing system installed in E/R was last annually serviced on July 2022 by Marine Fire Protection. System is required to be serviced annually by certified servicing company.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2023
Resolution: MI received servicing documentation for Fireboy system
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 November 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including inflatable buoyant apparatus. IBA was not available for inspection as it was being serviced by servicing facility. Provide service report once IBA is reinstalled on vessel. Prior to operating in cold waters
Action required: 705 - Other - as specified
Resolved 30 December 2023
Resolution: MI received servicing report for IBA and verified installation onboard
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 December 2020 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date of the COI. Vessel exceeded 3 month interval on 05DEC2020. Vessel is required to complete a satisfactory annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 1 April 2021
Resolution: Conducted annaul exam.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 March 2020 Resolved
Due to COVID-19 circumstances beyond the control of the vessel, the vessel is unable to meet the timeframe required by 46 CFR 176.107. Vessel is allowed 90 days to continue operations in accordance with the COI, and is required to make itself available for inspection prior to 30JUN2020. Issued CG-835v code 705c to extend Drydock exam 90 days.
Action required: 705 - Other - as specified
Due 30 June 2020
Resolved 29 June 2020
Resolution: Conducted satisfactory Hull Examination using objective evidence Statement from O/O, video call and photographs.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 4 September 2019 Resolved
Ensure one or more placards meeting the requirement of this section are posted. Garbage discharge placard is faded. Replace garbage discharge placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2019
Resolved 18 September 2019
Resolution: Garbage placard is posted.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 September 2019 Resolved
Placards containing instructions for the donning and use of the lifejackets onboard must be posted. Current life jacket placard is faded. Replace life jacket instruction placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2019
Resolved 18 September 2019
Resolution: Lifejacket donning instructions are posted.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 September 2019 Resolved
A durable placard must be posted next to all radiotelephone installations. Wordson emergency broadcast placard are faded. Replace emergency broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2019
Resolved 18 September 2019
Resolution: Emergency radio broadcast instructions are posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2019 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel exceeded 3 month interval on 04DEC18. Vessel required to undergo satisfactory annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2019
Resolved 17 July 2019
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 April 2018 Resolved
Complete satisfactory drydock/hull examination.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 1 May 2018
Resolution: Credit Drydock completed 01MAY18.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 February 2017 Resolved
INSTALL UNEXPIRED EPIRB HYDROSTATIC RELEASE DEVICE. TOTAL PERSONS ALLOWED TO NOT EXCEED 10, AS LIMITED BY CAPACITY OF INFLATABLE BUOYANT APPARATUS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 18 February 2017
Resolution: Valid hydrostatic release confirmed. Full passenger reinstated.
Documentation › Certificates/Documents › FCC SSL
Issued 1 February 2017 Resolved
Official number on FCC Station License is incorrect. Provide Station license with corrected Official number per 47 CFR 80.13
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 18 February 2017
Resolution: Valid station license confirmed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 February 2017 Resolved
Name of boat not marked on life ring. Corrected on the spot.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 1 February 2017
Resolution: Properly marked with permanent marker.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 1 February 2017 Resolved
Name of boat not marked on 02 excess child-size lifevests. Corrected on the spot.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 1 February 2017
Resolution: Marked properly with permanent marker.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 January 2017 Resolved
Complete a satisfactory USCG annual inspection, prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2017
Resolution: Completed satisfactory annual inspection.
Lifesaving › Hand Flares › Quantity
Issued 3 January 2017 Resolved
Provide 02 additional hand red flares to bring total complement to 06, as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 1 February 2017
Resolution: 04 red rocket parachute flares brought aboard.
Construction/Loadline › Hull › Bottom Plating
Issued 1 March 2016 Resolved
Repair cracked backing plate for port side rudder post.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 13 March 2016
Resolution: Vessel replaced backing plate to the satisfaction of CG Marine Inspector. The old plate was cracked beyond repair.
Stability › Watertight Integrity › General
Issued 1 March 2016 Resolved
Replace warn gaskets on hatches leading to engine room.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 13 March 2016
Resolution: Vessel replaced gaskets on hatches leading to the engine room to the satisfaction of CG Inspector.
Engineering › Bilge Water Management System › Interface Detector
Issued 7 January 2016 Resolved
AUDIBLE ALARM FOR BILGE HIGH LEVEL IN ENGINE ROOM NOT FUNCTIONING, IAW 46CFR182.530.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2016
Resolved 7 January 2016
Resolution: PROPERLY FIXED THE AUDIO INDICATOR FOR THE ENGINE ROOM BILGE HIGH LEVEL ALARM.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 7 January 2016 Resolved
OIL POLLUTION PLACARD NOT ON BOARD VESSEL, IAW 33CFR155.450.
Action required: 705 - Other - as specified
Due 7 January 2016
Resolved 7 January 2016
Resolution: MASTER PROVIDED OIL POLLUTION PLACARD.
Lifesaving › Hand Flares › Quantity
Issued 7 January 2016 Resolved
VESSEL MISSING 04 RED HAND FLARES, IAW 46CFR180.68.
Action required: 705 - Other - as specified
Due 7 January 2016
Resolved 7 January 2016
Resolution: MASTER PROVIDED 04 REQUIRED FLARES.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 January 2016 Resolved
LIFEJACKET COUNT ON LABEL IS NOT LEGIBLE, IAW 46CFR185.604.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2016
Resolved 7 January 2016
Resolution: MASTER PROVIDED NEW LIFEJACKET MARKINGS FOR STORAGE SPACE.
Navigation › Piloting/Steering › Marine Charts
Issued 7 January 2016 Resolved
CHARTS ARE OUT-OF-DATE, IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 14 January 2016
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 January 2016 Resolved
US COAST PILOT IS OUT OF DATE, IAW 46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 14 January 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 January 2016 Resolved
COAST GUARD LIGHT LIST OUT OF DATE, IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 14 January 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 December 2015 Resolved
COMPLETE A SATISFACTORY USCG ANNUAL INSPECTION, PRIOR TO CARRYING PASSENGERS, IAW 46CFR176.500.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2016
Resolution: CONDUCTED SATISFACTORY ANNUAL INSPECTION ON 07JAN2016.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.