Records from 2008 to 2023. Most recent: inspection, 31 October 2023.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2008
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 April 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
31 October 2023
Administrative Inspection · Internal Structural Exam · Examination of Repairs · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7818202
10 March 2021
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7153004
10 March 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6922952
21 November 2018
Internal Structural Exam · MTSA Verification · Cargo Tank Internal · Examination of Repairs · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6584992
9 November 2018
Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6578299
25 October 2017
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6293301
27 October 2016
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6030864
14 October 2015
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5741855
8 August 2015
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5211710
28 July 2015
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5200957
28 July 2015
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5225819
12 November 2014
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5021118
23 August 2013
MTSA Verification · Cargo Tank Internal · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4689974
20 September 2012
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4445995
14 September 2012
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4439245
30 September 2011
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4157130
13 August 2010
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3822932
7 August 2009
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3558218
3 June 2008
Internal Structural Exam · Cargo Tank Internal · Hull Examination · Initial Certification · MTSA Verification · Initial Construction-Excluding Oversight
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3247688
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 14 September 2012
Resolved
Portside vapor connection needs a 1" stud permanently attached. Vessel must keep vapor spool piece available if VCS is utilized for transfer operations.
Action required: 705 - Other - as specified
Due 14 October 2012
Resolved 20 September 2012
Resolution: 1" stud is now permanently attached to the portside vapor connection.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 3 June 2008
Resolved
Vessel owner shall prove that cargo pump engine unit is in complete compliance with 46 CFR 111.105-31(l).
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 13 August 2010
Resolution: Observed engine, cleared deficiency.