MAURY USCG vessel records
← All vessels

LACANAU

LACANAU is a 2007 tank ship. The Coast Guard has recorded 14 inspections since 2016, most recently in December 2021, along with 8 deficiencies and 1 operational control.

Records from 2016 to 2021. Most recent: inspection, 8 December 2021.

Built
2007
Last inspected
8 December 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 December 2021
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9377066
936308
Flag
FRANCE
Maury page id
psix-936308

Documentation record

Tonnage as PSIX records it7020 - Convention (Subpart B), Gross Ton
3294 - Convention (Subpart B), Net Ton
11674 - Dead Weight, Metric Ton
15132 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

14 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

8 December 2021 Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7364412
26 August 2021 PSC B · COC-CHEM & TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7291026
12 June 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6973122
12 June 2019 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6707192
6 June 2018 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6429069
4 June 2018 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6433582
4 July 2017 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6197935
3 July 2017 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6193610
28 March 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6112181
25 December 2016 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6062272
22 October 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6027682
10 October 2016 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6021645
3 May 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5868000
22 April 2016 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5855414

Deficiency record · 8

14 - Pollution Prevention › 148 - Ballast Water › Ballast water report
Issued 8 December 2021 Resolved
The master, owner, operator, agent or person in charge of a vessel must submit a ballast water report using methods specified at NBIC's website. Vessel incorrectly placed wrong drydock date on NBIC email. 33CFR151.2060(b)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 8 December 2021
Resolved 8 December 2021
Resolution: Vessel updated thier NBIC report.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 June 2020 Resolved
Fire protection systems and fire fighting systems and appliances shall be properly maintained ready to use. During the fire montior test with main fire pumps it was noted that there was a hole on the foam main line. Hole did not affect fire system pressure and there was adequate pressure. It is noteworthy of mention that there is alot od visible corrosion on fire and foam main and throughout the deck. 74SOLAS II-2/14
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2020
Resolved 30 June 2020
Resolution: Recieved Class Report acknowleding repair and clearing the outstanding item.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 3 July 2017 Resolved
The operator of a vessel equiped with ballast tanks that operates with the U.S. must employ one of the following BWM methods: (1-5). The vessel has been loading ballast in a foreign port and discharging the same ballast in the U.S. ports without conducting a ballast water exchange or employing any other approved method of BWM as stated in 33CFR151.2025. The vessel conduct exchange at 12NM in SJ.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Resolved 4 July 2017
Resolution: Vessel carried out ballast water exchange between San Juan and St Croix. Exemption from Sector San Juan allowed this exchange to be conducted.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 25 December 2016 Resolved
All oil tankers of 150 gross tons and above shall have an operating ODME. Vessel's ODME is not operational.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 28 March 2017
Resolution: Vessel sent correspondence with technician report testing a new ODME and Class survey statement attesting conformity.
Navigation › Collision/Grounding Avoidance › Radar
Issued 22 October 2016 Resolved
All ships 3000 gross gross tonnage and upwards shall have a second radar functionally independent of the other. S-Band radar found inoperable. 74SOLAS(14con)V/19.2.7.1 - 40A
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 October 2016
Resolved 25 December 2016
Resolution: Received class report
Navigation › Piloting/Steering › Marine Charts
Issued 22 October 2016 Resolved
1599 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. ECDIS was found inoperable. 74SOLAS(14con)I/11 - 40A
Action required: 705 - Other - as specified
Due 22 October 2016
Resolved 25 December 2016
Resolution: Received class report
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 22 April 2016 Resolved
9900-The vessel's bunker piping had not been hydrostatically tested at 1.5 times the maximum allowable working pressure since 2012. Vessel is prohibited from bunkering in the US until the proper tests have been conducted. 33 CFR 156.17(f). Code 40c.
Action required: 703 - Prior to bunkering operations
Resolved 3 May 2016
Resolution: Vessel provided evidence of bunker lines being hydrostatically tested IAW 33CFR156.170.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 22 April 2016 Resolved
0799-Waste receptacles shall be constructed of non-combustible materials. PSCO observed that the waste receptacles in the vessel's galley and pantry are not made from non-combustible materials. 74 SOLAS (04) II-2/4.4.2. Code 50ac.
Action required: 705 - Other - as specified
Due 22 May 2016
Resolved 7 May 2016
Resolution: VESSEL PROVIDED PICTURES AND RECIEPTS FOR ALL REPLACED WASTE RECEPTACLES ONBOARD.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.