Tonnage as PSIX records it13893 - Convention (Subpart B), Gross Ton 4388 - Convention (Subpart B), Net Ton 18110 - Dead Weight, Metric Ton 26255 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
7 inspections, each with its date, unit and type; 1 deficiency with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 20 November 2022Resolved
The equipment should be capable of producing inert gas with an oxygen content at no time greater than 5% by volume subject to the special requirements of Chapter 17.
PSCO observed PSA nitrogen generator plan out of order. As the vessel has Type "C" tanks, dry air is sufficient for environmental control in the spaces surrounding the tanks. However, vessel is NOT authorized to carry those products listed on the Subchapter "O" endorsement which by Chapters 17 and 19 require inert gas in the vapor space, prior to the repair of the PSA plant to the satisfaction of the Coast Guard.
74 SOLAS (20) VII/13.1
1993 IGC 9.5.1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 22 March 2023
Resolution: Attending MI verified and witnessed proper operation of Nitrogen Generation. Cleared deficiency. See PSC Form A & Form B issued 22MAR2023, MISLE Act. No. 7594086