ARIES SUN is a 2006 tank ship. The Coast Guard has recorded 17 inspections since 2008, most recently in November 2020, along with 7 deficiencies and 1 operational control.

Records from 2008 to 2020. Most recent: inspection, 30 November 2020.

Built
2006
Last inspected
30 November 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9321847 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
936466
Flag
LIBERIA
—
Maury page id
psix-936466

Inspections, by type

…with no type recorded3
Years with a record 6 calendar years (2008–2020)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it59158 - Convention (Subpart B), Gross Ton
36052 - Convention (Subpart B), Net Ton
131630 - Displacement, Metric Ton
115567 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

30 November 2020 PSC B · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7093914
28 July 2020 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7018314
19 June 2020 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6981279
19 June 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6986716
1 October 2019 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6816737
27 September 2019 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6822421
13 July 2018 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6477608
20 May 2018 COE-Dockside · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6418833
27 April 2018 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6400675
18 January 2018 Administrative Inspection · COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6338515
2 December 2017 COE-Administrative · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6312444
12 October 2017 Ballast Water Examination · COC-TVE Renew · ISPS II Exam · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6281270
31 July 2015 ISPS II Exam · Ballast Water Examination · COC-TVE Renew · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5200272
29 July 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5205303
29 July 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5239039
2 July 2008 ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3255032
17 January 2008 COC-TVE Renew
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3131864

Deficiency record · 7

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 19 June 2020 Resolved
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situatuions the safety management system should provide for specific measures aimed at promoting the reliabilty of such equipment or systems. these measures should include the regular testeing... The current SMS procedure for inspection of bunker tanks are on a 60 month cycle. A review of the frequency of bunker tank inspections with through piping penetrations are not specified and shall be addressed. (74SOLAS(14) IX/3.1), (ISM CODE 10.3)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2020
Resolution: Flag state submitted documentation attesting to review of SMS procedures regarding frequency of tank inspections with through piping penetrations.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 19 June 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. The vessel suspects a bunker fuel leak from the 1S fuel tank is leaking fuel into the ballast discharge line. The vessel was issued a NOV for discharge of oil into U.S. waters by Sector Houston-Galveston IMD. The vessel shall submit a repair plan and class report attesting that repairs have been conducted prior to arrival at next U.S. port after sailing foreign. (MARPOL I/ 6.4.1)
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 July 2020
Resolution: Received, reviewed and accepted class report / proper documentation from the Flag state and class society, stating the deficiency was rectified
Engineering › Fuel Oil Service System › Piping
Issued 31 July 2015 Resolved
1410 - Propulsion Main Engine - External high-pressure fuel delivery lines between the high pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high-pressure line failure. The jacket on the main engine, 5th cyliner, aft fuel injector line was damaged. 74 SOLAS (04) II-2 / 4.2.2.5.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2015
Resolution: Vessel''s crew replaced damaged injector line with a new spare onboard.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 31 July 2015 Resolved
1621 - MF Radio Installation - An MF radio installation capable of transmitting and receiving, for distress and safety purposes. MF radio transmitter only able to receive messages, and cannot transmit. 74 SOLAS (09) IV / 9.1.1
Action required: 705 - Other - as specified
Due 30 August 2015
Resolved 2 August 2015
Resolution: Vessel provided service report from Navtech Marine Electronics indicating satisfactory repair and operation of radar.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 31 July 2015 Resolved
0915 - Signs Indications - The high-level alarm and tank overfill alarm shall be identified with the legend "TANK OVERFILL ALARM" in black letters at least 2 inches high on a white background. The legend was in black letters on a dark background. 46 CFR 39.2007
Action required: 705 - Other - as specified
Due 14 August 2015
Resolved 2 August 2015
Resolution: Vessel''s crew repainted the marking as required.
Engineering › Sea-water System (primary cooling) › Piping
Issued 31 July 2015 Resolved
1499 - Other (Prop. & Aux. Machinery) - Piping systems shall be of a design and construction adequate for the service for which they are intended. Saltwater piping on discharge side of auxiliary engine cooler was found to have an unapproved temporary repair. 74 SOLAS (04) II-1 / 26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 October 2017
Resolution: Piping system fixed and placed in proper service.
Construction/Loadline › Markings › Load Line Mark
Issued 31 July 2015 Resolved
1200 - Load Lines - The ring, lines and letters shall be permanently marked on the sides of the ships. The vessel's load line marking/mark of assigning authority is painted but not permanently marked. ICLL Annex I / 8 Note - Form B indicates that this must be corrected at next dry dock.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 12 October 2017
Resolution: Reviewed proper documentation from LR clearing deficiency. Load line repaired at dry-dock.

Ownership record