Records from 2016 to 2022. Most recent: inspection, 4 April 2022.
Documentation record
Tonnage as PSIX records it58442 - Simplified, Gross Ton
58442 - Convention (Subpart B), Gross Ton
30588 - Simplified, Net Ton
30588 - Convention (Subpart B), Net Ton
122173 - Displacement, Metric Ton
104610 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Inspection history · 9
4 April 2022
PSC B · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7418931
23 February 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7400963
21 September 2021
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7317122
17 June 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7228009
9 March 2021
COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7150851
25 February 2020
PSC B · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6912323
8 March 2019
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6638596
21 September 2017
Administrative Inspection · ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6271342
3 June 2016
Ballast Water Examination · ISPS II Exam · COC-TVE Renew · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5895850
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 March 2019
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATION TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED THE EMERGENCY GENERATOR (E/G) TURN OFF, AFTER A FEW SECONDS OF RUNNING. ACCORDING TO CHIEF ENGINEER (C/E) THE E/G GOVERNOR RUNNING SPEED ADJUSTMENT SCREW IS LOOSENING DUE TO VIBRATION, CAUSED WHILE ENGINE IS RUNNING. THIS ISSUE WAS IDENTIFIED A FEW WEEKS AGO, BY C/E, ALTHOUGH AT THAT TIME THE ENGINE DID NOT TURN OFF. C/E RECOMMENDATION IS TO REPLACE GOVERNOR IN ORDER TO ENSURE RANDOM E/G SHUTDOWNS DO NOT OCCUR. E/G WAS TESTED AFTER SCREW WAS ADJUSTED AND E/G WAS ABLE TO BE STARTED AND REMAIN ON. THES WAS TESTED 04 CONSECUTIVE TIMES W/OUT ENGINE RANDOMLY STOPPING. 74 SOLAS (14) CH I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2019
Resolution: Received Class Surveyor [name withheld]3641792, stating repair was examined, engine tested and the system is satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 March 2019
Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. PSCO OBSERVED F/O TRANSFER LINE VALVE LEAKING FUEL FROM VALVE COMPONENT. VALVE IS LOCOATED IN ENGINE ROOM. 74 SOLAS (2004) CH II-1/ REG 26
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2019
Resolution: Received Class Surveyor [name withheld]3641792, stating valve packing was replaced, tested under operational conditions and is satisfactory.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 March 2019
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE CARGO PUMP EMERGENCY SHUTDOWN AUDIBLE AND VISUAL ALARM IS NOT VEING INDICATED IN THE CARGO CONTROL ROOM OR ENGINE CONTROL ROOM. THE EMERGENCY SHUTDOWN WILL STILL COMMENCE SHUTDOWN. 74 SOLAS (14) CH I/11. 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2019
Resolution: Received Class Surveyor [name withheld]3641792, stating the remote shut down system was repaired, tested and is satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 8 March 2019
Resolved
NO VESSEL MAY ANCHOR IN A "DEAD SHIP" STATUS (PROPULSION OR CONTROL UNAVAILAVLE FOR NORMAL OPERATIONS) AT ANY ANCHORAGE OTHER THAN IN ANCHORAGE 09 AS SPECIFIED IN TABLE 110.224(D)(1). VESSEL IMOBOLIZED M/E AT APPROX 0900 HRS, 08MAR2019, WITHOUT MEETING TABLE 110.224(D)(1) REQUIREMENTS(TUG REQUIREMENTS). 33 CFR 110.224(A)(18) 10 C.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2019
Resolution: Vessel hired tug to be on 15 minute standbye, thereby following the requirements of the CFR.