CSAV RIO NEVADO is a 2007 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in May 2023, along with 5 deficiencies and 3 operational controls.
Records from 2016 to 2023. Most recent: inspection, 15 May 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it46800 - Convention (Subpart B), Gross Ton 14264 - Convention (Subpart B), Net Ton 27058 - Displacement, Ton 12221 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
15 May 2023PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7682245
7 July 2021Ballast Water Examination · PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7241478
27 May 2021Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7208235
20 December 2019Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6873327
6 December 2018Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6593322
6 November 2018Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6569031
28 August 2018Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6525393
3 January 2018Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6332259
21 July 2017ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6212336
2 June 2017Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6162411
6 October 2016Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6018455
15 June 2016PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5908626
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 6 November 2018Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the code. The food rations required to be on each lifeboat shall be kept in airtight packaging. 19 food rations were found with broken seals.
74SOLAS(2014)CH III REG 34
LSA 4.8.8.12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2018
Resolution: New food rations ordered. Pictures, receipt, and class letter sent to our office.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 November 2018Resolved
Connections within the fuel supply and spill lines shall be constructed having regard to their ability to prevent pressurized oil fuel leaks while in service and after maintenance. 8 of 9 fuel pumps were found leaking, causing a fire hazard.
74SOLAS(04) CH II-1 REG 4.2.2.5.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2018
Resolution: Repaired / Rectified: Replaced new O-rings and valve housings with ship's spare for No. 2 to No. 9 and tested satisfactorily by MDO running of Main Engine F.O Supply and Circulating pump (approx. 7 bar) and cleaned spilled oil nearby F.O pumps side.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 November 2018Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. Wire chase in way of galley dry stores bulkhead was found to have open passage due to wiring installations. 74SOLAS(14) CHII-2 REG 14.2.1.1.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 November 2018
Resolution: Repaired / Rectified: The sealing compound (Type: KVM Sealing Compound, ABS Certificate no. : 07- HG301235-1-PDA) was fully inserted at cable coaming opening and found in order. Photos and class letter received.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 6 November 2018Resolved
All ships which undergo repairs related thereto shall continue to comply with at least the requirements applicablke to the ship. Soft patch in water-maker sea suction piping was found installed on board the vessel.
74SOLAS(04) CH II-1 REG 1.3.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 December 2018
Resolution: VESSEL SUBMITTED DOCUMENTS INDICATING THAT ALL NECESSARY REPAIRS WERE COMPLETED, INCLUDING CLASS SURVEY REPORT AND PHOTOGRAPHIC EVIDENCE.
Each vessel of 10,000 gt or more must have a second marine radar system that operates independently of the first. Vessels primary radar system - x band is not operational. 33cfr164.37a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2018
Resolution: Repaired equipment, submitted class survey and technician report.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.