MAURY USCG vessel records
← All vessels

CSAV RIO NEVADO

CSAV RIO NEVADO is a 2007 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in May 2023, along with 5 deficiencies and 3 operational controls.

Records from 2016 to 2023. Most recent: inspection, 15 May 2023.

Built
2007
Last inspected
15 May 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 May 2023
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9325180
936679
Flag
LIBERIA
Maury page id
psix-936679

Documentation record

Tonnage as PSIX records it46800 - Convention (Subpart B), Gross Ton
14264 - Convention (Subpart B), Net Ton
27058 - Displacement, Ton
12221 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

15 May 2023 PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7682245
7 July 2021 Ballast Water Examination · PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7241478
27 May 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7208235
20 December 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6873327
6 December 2018 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6593322
6 November 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6569031
28 August 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6525393
3 January 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6332259
21 July 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6212336
2 June 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6162411
6 October 2016 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6018455
15 June 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5908626

Deficiency record · 5

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 6 November 2018 Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the code. The food rations required to be on each lifeboat shall be kept in airtight packaging. 19 food rations were found with broken seals. 74SOLAS(2014)CH III REG 34 LSA 4.8.8.12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2018
Resolution: New food rations ordered. Pictures, receipt, and class letter sent to our office.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 November 2018 Resolved
Connections within the fuel supply and spill lines shall be constructed having regard to their ability to prevent pressurized oil fuel leaks while in service and after maintenance. 8 of 9 fuel pumps were found leaking, causing a fire hazard. 74SOLAS(04) CH II-1 REG 4.2.2.5.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2018
Resolution: Repaired / Rectified: Replaced new O-rings and valve housings with ship's spare for No. 2 to No. 9 and tested satisfactorily by MDO running of Main Engine F.O Supply and Circulating pump (approx. 7 bar) and cleaned spilled oil nearby F.O pumps side.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 November 2018 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. Wire chase in way of galley dry stores bulkhead was found to have open passage due to wiring installations. 74SOLAS(14) CHII-2 REG 14.2.1.1.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 November 2018
Resolution: Repaired / Rectified: The sealing compound (Type: KVM Sealing Compound, ABS Certificate no. : 07- HG301235-1-PDA) was fully inserted at cable coaming opening and found in order. Photos and class letter received.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 6 November 2018 Resolved
All ships which undergo repairs related thereto shall continue to comply with at least the requirements applicablke to the ship. Soft patch in water-maker sea suction piping was found installed on board the vessel. 74SOLAS(04) CH II-1 REG 1.3.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 December 2018
Resolution: VESSEL SUBMITTED DOCUMENTS INDICATING THAT ALL NECESSARY REPAIRS WERE COMPLETED, INCLUDING CLASS SURVEY REPORT AND PHOTOGRAPHIC EVIDENCE.
Navigation › Collision/Grounding Avoidance › Radar
Issued 4 January 2018 Resolved
Each vessel of 10,000 gt or more must have a second marine radar system that operates independently of the first. Vessels primary radar system - x band is not operational. 33cfr164.37a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2018
Resolution: Repaired equipment, submitted class survey and technician report.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.