MAURY USCG vessel records Sign in
← All vessels

MOLLY MOLASSES

MOLLY MOLASSES is a 2008 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2008, most recently in April 2026, along with 7 deficiencies.

Records from 2008 to 2026. Most recent: inspection, 16 April 2026.

Built
2008
Last inspected
16 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

936810
Flag
UNITED STATES
—
Maury page id
psix-936810

Inspections, by type

…with no type recorded3
Years with a record 16 calendar years (2008–2026)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

16 April 2026 Administrative Inspection · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8350699
10 March 2026 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8318652
5 March 2025 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8086061
28 February 2024 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7862469
21 February 2023 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7685330
2 March 2022 Hull Examination · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7407389
24 February 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7145543
25 February 2020 Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6924657
22 January 2020 Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6893996
25 February 2019 Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6637892
20 February 2019 Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6628862
12 September 2018 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6538987
5 March 2018 Deficiency Check · COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6370442
12 June 2017 Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6173812
12 June 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6174585
7 March 2017 Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6100198
29 February 2016 Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5829850
30 June 2012 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4362656
30 June 2012 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4364693
9 September 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4140470
10 March 2010 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3697452
2 March 2010 Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3688548
19 March 2009 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3438538
14 January 2009 In-Service Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3393933
21 May 2008 COI Inspection · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3212515
15 May 2008 Initial Certification · Internal Structural Exam · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3189949

Deficiency record · 7

Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 12 June 2017 Resolved
Vessel's main engine shutdown and failed to restart, issued CG-835 requirement to prove proper operation of main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2017
Resolution: Faulty sensor was replaced with new, operational test sat.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 March 2017 Resolved
Forward port external frame was found to be bent do to impact. Issued requirement to repair or replace bend frame.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 10 March 2017
Resolution: External frame was repaired by straightening out the angle-iron and making frame true.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 15 May 2008 Resolved
Properly mark vessel's name on hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2008
Resolution: Corrected
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 15 May 2008 Resolved
Properly mark vessel's name on all life rings and type one PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2008
Resolution: Corrected
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 May 2008 Resolved
Place on board all required adult and childs PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2008
Resolution: Corrected
Personnel › Training › Familiarization Training
Issued 15 May 2008 Resolved
Conduct required drills and vessel familiarzation with vessel master/crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2008
Resolution: Corrected
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 May 2008 Resolved
Prove proper operation of side curtain system deployment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2008
Resolution: Completed

Ownership record