Records in 2008. Most recent: inspection, 28 April 2008.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Engineering › Steering Gear System › Rudder
Issued 8 February 2008
Resolved
The port side steering gear is osolating. This movement is from the pump or the main control.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Resolution: Witnessed a satisfactory operational testing of steering gear
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 8 February 2008
Resolved
The SCBAs for both siuts are inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Resolution: Vessel bought 2 new SCBAand trained crew to use the new equipment.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 8 February 2008
Resolved
The remote pull on the #4 cylinder is broken therefore the cylinder cannot be remotely released.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Resolution: Cable was re-attached and tested
Lifesaving › Rescue Boat › Hull (rigid)
Issued 8 February 2008
Resolved
The rescue boat was inoperable. The rigid hull and inflatable section were not connected therefore the rescue boat could not float.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Resolution: Vessel purchase new rescue boat.
Communications › Internal Communications System › Sound-powered Telephone
Issued 8 February 2008
Resolved
No internal communications were operable on the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Resolution: Witnessed a satisfactory operational test of equipment
Accommodation/Occupational Safety › Ventilation › General
Issued 8 February 2008
Resolved
The CO2 room's forced ventilation system was inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Resolution: Witnessed operation of fan
Electrical › Lighting (service) › Lighting Fixture
Issued 8 February 2008
Resolved
During a PII inspection MSU Lake Charles personnel discovered multiple lamp covers were missing. Replace missing lamp cover
Due 8 March 2008
Resolved 22 February 2008
Resolution: Vessel purchased and installed 30 new lamps
Engineering › Steering Gear System › Rudder
Issued 8 February 2008
Resolved
Noticed excesive leaking thru both rudder post. Replace both port and starboard rudder post packing
Due 8 March 2008
Resolved 22 February 2008
Resolution: Packing replaced
Engineering › Diesel Engine (propulsion-electric) › Governor
Issued 8 February 2008
Resolved
Replace damaged tachometer sensor
Due 8 March 2008
Resolved 19 February 2008
Resolution: Witnessed a satisfactory operational test of tach
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 8 February 2008
Resolved
During a PII inspection notice substatial wastage on bilge pipping throught the engine room. Repair/ replace wataged pipping at next drydock.
Action required: 705 - Other - as specified
Resolved 28 April 2008
Resolution: MORMS inspectors conducted followup inspection. Piping replaced.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 8 February 2008
Resolved
During a PII inspection noticed a numerous safety violation on the vessel. Upon an expanded examination verified that the vessel personnel are following the SMS system as intended however, the vessel company is not supporting the vessel master request for damaged equipment replacement/repairs technician. Recomend and sms audit.
Action required: 705 - Other - as specified
Resolved 28 April 2008
Resolution: MORMS inspectors conducted follow up and noted the SMS audit that was successfully completed.