Records from 2008 to 2020. Most recent: inspection, 24 March 2020.
Inspection history · 27
24 March 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6930880
20 February 2020
Ballast Water Examination · PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6911582
19 July 2019
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6755441
19 July 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6755525
15 July 2019
ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6747986
25 September 2018
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6544856
23 January 2018
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6341986
24 September 2017
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6273497
16 February 2017
Administrative Inspection · ILO-147 Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6092025
3 June 2016
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5881871
7 December 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5776690
30 September 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5732531
24 September 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5728142
11 March 2014
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4811064
28 July 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4097302
26 July 2011
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4094731
26 July 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4101990
3 January 2010
MARPOL Annex II Examination · COC-CHEM Renew · MARPOL Annex VI Survey · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3656406
27 December 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3655676
7 April 2009
Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3447062
3 April 2009
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3444418
30 October 2008
In-Service Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3354441
29 October 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3353530
29 October 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3353659
5 July 2008
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3257897
9 June 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3231672
2 February 2008
PII Safety Exam · COC-TVE Renew · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3140612
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 20 February 2020
Resolved
12199 - other (tankers) - Each tankship with a vapor collection system must be fitted with a pressure sensing device located as close as practicable to the vessel vapor connection that measures the pressure in the main vapor collection line which has a high-pressure and a low pressure alarm. the aft vapr return line pressure guage and associated high- pressure/low pressure alarm is inoperable. Repair or replace inoperable pressure guage and associated alarm. 46 CFR 39.2013
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 March 2020
Resolution: VESSEL RECTIFIED REPAIRS FOR THE PRESSURE GAUGE AND ASSOCIATED HIGH/LOW PRESSURE ALARM FOR THE AFT VAPOR RETURN LINE.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 February 2020
Resolved
07108 - Ready availability of fire fighting equipment - Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. During engine room exam Port State Control Officer found main water supply valve for fire-fighting system (water mist) was closed. 74 SOLAS 2009 Cons. II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 20 February 2020
Resolution: Vavle position corrected with tamperseals to make sure the valve remains open. Sign posted informing to keep in open position after maintenance.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 September 2018
Resolved
07105 - Fire Safety - The Fire resistance of doors shall be equivalent to that of the division in which they are fitted.
The Class B door located between the machinery workshop and the electrician's workshop lacks a self closing mechanism and handle.
74 SOLAS (2009 Cons.) 11-2/9.4.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 September 2018
Resolved 25 September 2018
Resolution: Chief Engineer was able to replace entire door with fully functioning Class B fire resistant door with self closing mechanism and handle.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 25 September 2018
Resolved
11117 - Maintenance, testing and inspections of lifesaving appliances shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring reliability of such appliances. 01 Life Buoy self igniting light holder on 1st deck was affixed to a severely wasted railing repaired with Duct-tape. This provides inadequate support for the safety equipment.
Cite: 74 SOLAS (2014 Cons.) III/20.3.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 September 2018
Resolved 25 September 2018
Resolution: Life Buoy Holder was bolted to a sufficient railing.
Construction/Loadline › Structures › Door
Issued 24 September 2017
Resolved
Exterior superstructure doors could not demonstrate proper operation during the inspection. Doors were unable to be closed fully due to deterioration of the door jam and associated parts to the door jam and sill assemblies.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 January 2018
Resolution: Received ABS Class Report attesting to that all of the Class "A" Boundary doors and all of the exterior doors were fixed, maintenanced, repaired, and are all working properly.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 September 2017
Resolved
2 Class A Self closing fire doors leading into the galley space were unable to close without assistance.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 September 2017
Resolution: Reduced to 10b. Vessel's crew was able to make adjustment and demonstrate proper operation of the class A self closing doors to the galley.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 26 July 2011
Resolved
The circuit breaker supplying output power to vital bridge equipment is inoperable. Vessel is to make permanent repairs and submit a class report attesting to proper operation of power supply and all vital bridge equipment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2011
Resolution: Received class report from [name withheld] attesting to replacement of battery charger, and subsequent successful test and operation.
Construction/Loadline › Hull › Hull Plating
Issued 30 October 2008
Resolved
Make proper temporary repairs to the three fractures in the aft peak according to the proposal submitted by class. Temporary cement patches are to be removed and doubler plates are to be properly fitted and welded over the fractures.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 7 April 2009
Resolution: Double welds were placed over the damaged portion of the hull (photos in activity). An extra tug will be used in the future for mooring operations.
Construction/Loadline › Hull › Hull Plating
Issued 29 October 2008
Resolved
Class to attest to the condition of hull plating damaged by bridge allision.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 30 October 2008