LOXANDRA

LOXANDRA is a 2007 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in August 2026, along with 6 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 5 August 2026.

Built
2007
Last inspected
5 August 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 August 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9343871
937434
Flag
LIBERIA
Maury page id
psix-937434

Documentation record

Tonnage as PSIX records it49973 - Convention (Subpart B), Gross Ton
30679 - Convention (Subpart B), Net Ton
92576 - Dead Weight, Metric Ton
107967 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

5 August 2026 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8459569
1 June 2026 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8376298
5 April 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8343139
14 September 2021 Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7311822
18 November 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6852108
18 August 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6515657
10 July 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6457665
10 April 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6116991
30 March 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5838023

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 September 2021 Resolved
07126 - Means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil collecting in main engine void space starboard side lower deck, and in metal pans under Number 2 and 3 generator. Oily rags were found in multiple void spaces around main engine. Additionally PSCO observed plastic containers with fuel oil in purifier room. 74 SOLAS (04 II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2021
Resolved 14 September 2021
Resolution: Received class survey report rectifying this deficiency.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 September 2021 Resolved
04103 - Alleyways, stairways, and exits giving access to the muster and embarkation stations shall be lighted. PSCO observed numerous emergency lights on deck and surrounding the accommodations that were missing or inoperable. 74 SOLAS (20) III/11.5
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2021
Resolved 14 September 2021
Resolution: Received class survey report rectifying this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2021 Resolved
02108 - All electrical apparatus shall be so installed as to not cause injury when handled or touched in a normal manner. PSCO observed light coverings on deck secured with zipties. 74 SOLAS (20) III/11.5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2021
Resolved 5 April 2026
Resolution: Class report attesting to rectification.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 18 November 2019 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. Incinerator was missing bricks, exposing the housing. 74SOLAS(04)II-1/26
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 19 November 2019
Resolution: Recieved class report.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 10 July 2018 Resolved
0720- FIRE FIGHTING EQUIPMENT - The function of fixed firefighting detection and fire alarm system shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at appropriate temperature to which the detector is designed to respond. PSCO observed UV lamp was INOP and crew were testing with controlled burn of paper. Vessels crew couldn't provide evidence that this is an approved means of testing flame detectors. SOLAS 74 a Cons. II-2/ Action taken: 40a
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 August 2018
Resolution: PSC NOLA RECEIVED A CLASS REPORT FROM CCS SATISFYING THE REQUIREMENT.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 July 2018 Resolved
0750-Fire prevention-The maintenance plan shall be kept on board ship and be available for inspection. The maintenance plan shall include at least the following: fixed fire detection and fire alarm system. vessel could not provide procedures for the testing of fixed fire detection system. SOLAS 74 a Cons. II-2/14.2.2 Action taken- 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 August 2018
Resolution: PSC NOLA RECEIVED A CLASS REPORT FROM CCS SATISFYING THE REQUIREMENTS.