Records from 2016 to 2023. Most recent: inspection, 7 August 2023.
Inspection history · 9
7 August 2023
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7752799
31 January 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7630093
22 March 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7160897
18 December 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7107460
2 October 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7070258
24 December 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6871757
15 November 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6575319
4 October 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6280915
16 March 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5829934
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 August 2023
Resolved
PSCO Observed inoperable flame detector over incinerator. 74SOLAS(09) II-2/14.2.1.1.2 Code 10c
Action required: 10 - Deficiency Rectified
Due 7 August 2023
Resolved 7 August 2023
Resolution: Crew replaced with new spare flame detector and witnessed satisfactory test.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 7 August 2023
Resolved
PSCO Observed OWS 3 way valve cycling from open and closed position during testing. MARPOL I/14.7 Code 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2023
Resolved 9 August 2023
Resolution: Crew observed air in the system, which caused the pressure to fluctuate. Crew drained air. Class witnessed opening and closing of 3-way valve with no issues.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 August 2023
Resolved
PSCO observed Port lifeboat inoperable. 74SOLAS(20)III/20.2
Action required: 10 - Deficiency Rectified
Due 7 August 2023
Resolved 7 August 2023
Resolution: Crew was able to provide satisfactory propulsion test in presence of PSCO.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 December 2020
Resolved
In a ship which oil is used, the arrangemnts for distribution shall be as such to ensure the safety of the ship. PSCO observed fuel oil leak on #2 fuel oil booster pump in vicinity of steam heaters. SOLAS 04 II-2/4.2.2
Action required: 10 - Deficiency Rectified
Resolved 18 December 2020
Resolution: PSCO witnessed satisfactory replacement of pump seal packing.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 18 December 2020
Resolved
The company shall establish procedures, plans, and instructions for key shipboard operations concerning the safety of personnel and ship. PSCO observed fixed hypermist system inoperable (valve closed, breaker open) and emergency generator fuel supply valve closed following pre-arrival checks. Submit corrective action plan. ISM Code 7, SOLAS (04) II-1/43.3.2, SOLAS (04) II-2/10.5.6.2
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 March 2021
Resolution: Received class report from class that procedures for testing shipboard equipment were updated, and fleet-wide safety brief distributed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2020
Resolved
...All metal sheaths and armour of cables shall be electrically continuous and shall be earthed. PSCO observed incinerator waste oil service pump with improper repair splices. SOLAS (04) II-1/45.5.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 March 2021
Resolution: Received class report from class NKK that waste oil service pump power cable had been satisfactorily replaced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 December 2020
Resolved
Fixed local fire-extinguishing sytems are to protect the purifiers of heated fuel oil and internal combustion machinery used for ship's power generation. PSCO observed flame detectors over port SSDG and fuel oil purifiers with missing covers.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 March 2021
Resolution: Received report from class NKK that flame sensors were satisfactorily installed with flame cone covers.