Records from 2008 to 2026. Most recent: inspection, 12 June 2026.
Inspection history · 26
12 June 2026
Deficiency Check · PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8394734
31 March 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8102391
20 February 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8081788
13 February 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8079275
15 August 2024
COC-TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7981660
30 November 2022
COC-TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7601756
4 December 2021
COC-TVE Renew · Ballast Water Examination · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7362254
4 December 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7362483
28 November 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7358053
18 November 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6309281
16 November 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6307786
15 October 2017
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6287732
2 May 2017
COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6132883
12 November 2016
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6036009
7 October 2015
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5734173
6 October 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5736928
6 October 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5737123
12 August 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4952589
19 June 2014
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4892990
23 May 2014
ISPS III Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4862140
27 March 2014
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4814328
26 May 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4334991
8 May 2012
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4305255
25 February 2012
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4250892
20 December 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3913623
12 February 2008
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3146037
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 12 June 2026
Resolved
The system shall be so designed to ensure that if the oxygen content exceeds 5% by volume, the inert gas shall be automatically vented to atmosphere. PSCO observed high O2 and vent to atmosphere set at 8%.
74 SOLAS 11-2/5.5.1.3 FSS 15.2.2.2.4
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 12 June 2026
Resolved 12 June 2026
Resolution: Set point was lowered to 5% set point.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 June 2026
Resolved
The machinary, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which it is intended and shall be so installed and protected as to reduce to a minimum any danger to persons onboard, due regard being paid to moving parts, ho surfaces and other hazards. PSCO noted minor, consistent fuel oil leak on #1 and #3 generators.
74 SOLAS 11-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2026
Resolved 16 June 2026
Resolution: Damaged O-rings and gaskets replaced on fuel filter housing and fuel pump on #1 and #3 generators and verified by ABS via remote survey.
10 - Safety of Navigation › N/A - No Subsystem › Revolution counter
Issued 20 February 2025
Resolved
Rudder, propeller, thrust, pitch and operational mode indicators, or other means, to determine and display rudder angle, propeller revolutions, the force and direction of thrust and, if applicable, the force and direction of lateral thrust and the pitch and operational mode, all to be readable from the conning position. Vessels main engine propeller RPM indicator repeater unit on wheel house overhead panel and starboard wing are not operational. 74 SOLAS V/19.2.5.4
Action required: 60 - Rectify deficiencies prior to movement
Due 22 February 2025
Resolved 21 February 2025
Resolution: Received class report certifying replacement of repeater cables.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 November 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed steady water leak from the #1 main engine cylinder. This jacket water leak was reported to be caused by a worn o-ring. Observed issue could cause loss of cylinder compression and main propulsion loss, presenting a clear hazard to the ship, port and crew.
SOLAS 2014 I/11A
CODE: 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2022
Resolution: Resolved after proof of correction.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 30 November 2022
Resolved
Each incinerator shall meet the following specifications in IMO resolution MEPC.244(66). These guidelines require incinerator walls to be protected by bricks/refractory to maintain satisfactory temperatures. PSCO observed brick/refractory on incinerator door interior to be heeavily deteriorated and worn through reducing thermal and fire protection.
MARPOL VI/16.6.1
IMO resolution MEPC.244(66) Annex 3.3
Code: 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2022
Resolution: Resolved after proof of correction.
Engineering › Freshwater System (jacketwater cooling) › Level Control
Issued 12 August 2014
Resolved
1410: The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. crew reported the main engine number three cylinder has excessive leak from upper cooling water jacket. SOLAS(2004 cons. ED.) II-1 / 26..1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2014
Resolution: Received class report verifying safe operation of the cooling water jacket.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 23 May 2014
Resolved
1840 - The high level alarm must have an audible and visible alarm that can be seen and heard where the cargo transfer is controlled. The high level alarm could not be heard in the cargo control room. 46 CFR 39.20-7 (c)(3); 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 June 2014
Resolution: [name withheld] from SecDelBay received report from Hellespont Ship Management, owner of the vessel, stating that a blown fuse caused the malfunction. Fuse was replaced and the high level alarm and light are functioning properly.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 23 May 2014
Resolved
1830 - The high level alarm must be identified with the legend, "High Level Alarm" in black letters at least 50 millimeters high on a white background. The overfill alarm must be identified with the legend, "Tank Overfill Alarm" in black letters on a white background. Neither the high level or tank overfill alarms are labeled. 46 CFR 39.20-7 (c)(2); (d)(3): 40c
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 June 2014
Resolution: [name withheld] from SecDelBay received a report from Hellespont Ship Management, owner of the vessel, stating that the high level and tank overfill alarms were labeled. Attached to the report was a picture confirming that the alarms were labeled.
Electrical › Electric Generation Source (emergency) › Generator
Issued 25 February 2012
Resolved
1430 - Auxiliary Engines - Emergency Generator shall be capable of being readily started in their cold condition at a temperature of 00 degrees Celsius. Vessels anti-freeze storage on emergency generator has a small leak. SOLAS 74 (04) ll-1/44.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 March 2012
Resolution: Received photographs from the vessel Master which illustrate satisfactory repairs to the antifreeze tank.