MAURY USCG vessel records
← All vessels

BW DANUBE

BW DANUBE is a 2007 tank ship. The Coast Guard has recorded 3 inspections since 2018, most recently in November 2020, along with 3 deficiencies.

Records from 2018 to 2020. Most recent: inspection, 3 November 2020.

Built
2007
Last inspected
3 November 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 November 2020
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2018–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9365001
937896
Flag
SINGAPORE
Maury page id
psix-937896

Documentation record

Tonnage as PSIX records it89803 - Displacement, Ton
76000 - Dead Weight, Ton
43797 - Convention (Subpart B), Gross Ton
21967 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

3 November 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7089278
6 September 2020 COC-TVE Renew · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7049987
23 November 2018 COE-Offshore · ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6582444

Deficiency record · 3

10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 6 September 2020 Resolved
All arrangements used for pilot transfer...shall be regularly inspected to ensure that they are safe to use. Current inspection procedures and records only mention inspection of pilot ladder and do not include other arrangements, specifically strong points.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2020
Resolved 3 November 2020
Resolution: USCG satisfied with class report
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 6 September 2020 Resolved
The company should establish procedures, plans and instructions including checklists as appropriate, for key shipboard operations concerning the safety of personnel, ship and protection of the environment. The various tasks should be defined and assigned to qualified personnel. Current pilot ladder rigging procedures lack adequate detail. Current procedure does not clearly indicate whether or not pilot ladder should be rigged over handrail, which is how ship's crew currently has pilot ladder arranged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2020
Resolved 3 November 2020
Resolution: USCG satisfied with class report
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 September 2020 Resolved
Where the atmosphere in double hull spaces cannot be reliably measured using flexiable hoses, such spaces shall be fitted with permanent gas sampling lines. WBT1S experienced a flow fault that could not be cleared onboard during the exam.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2020
Resolved 3 November 2020
Resolution: USCG satisfied with class report

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.