Records from 2016 to 2026. Most recent: inspection, 5 February 2026.
Inspection history · 20
5 February 2026
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8304115
23 January 2025
Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8068881
11 December 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7837698
25 July 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7752237
13 March 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7709268
18 January 2023
Administrative Inspection · Hull Examination · Deficiency Check · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7621100
27 January 2022
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7386692
25 February 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7146480
22 January 2021
Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7128789
24 January 2020
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6895718
7 March 2019
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6637833
18 December 2018
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6599827
23 March 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6383632
7 February 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6351034
1 March 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6098577
17 January 2017
Administrative Inspection · DAPI Audit · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6072070
1 July 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5983290
24 March 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5840511
27 January 2016
Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5804640
12 January 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5796150
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 January 2024
Resolved
For fixed gas fire extinguishing systems..;the owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Marine Inspector was notified by owner that fire service company had not supplied servicing report. Supply report to Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2024
Resolved 30 April 2024
Resolution: Received annual firefighting servicing certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 2 March 2022
Resolved
The owner of a documented vessel must annually renew each endorsement upon the current Certificate of Documentation for that vessel in accordance with 67.163.Vessel's COD is expired and may not operate with passengers. Vessel can operate 6 or less passengers for hire provided the vessel has proper state documentation, and the requirements of 46 CFR 176.114 shall apply. Equipment required by the certificate of inspection shall not be removed or altered without the permission of the cognizant officer in charge marine inspection (OCMI).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2022
Resolution: Vessel has valid COD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2022
Resolved
Valves for removing water or impurities from the F/O system are permitted so long as they are fitted with caps or plugs to prevent leakage. Petcock plug was missing. Replace plug.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 9 March 2022
Resolution: plug installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2022
Resolved
All equipment must be installed an maintained. Oil change pump rusted off bracket and was improperly stored as a result. Remount oil change pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 9 March 2022
Resolution: remounted
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 2 March 2022
Resolved
Provision must be made for openings for a space protected by a fixed gas fire extinguishing system. One vent closure cover was missing. Provide proof of vent cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 9 March 2022
Resolution: vent clousre added
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 March 2022
Resolved
Placards containing instructions for the donning and use of life jackets must be posted. Placard was not properly mounted. Remount placard.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: reattached placard
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 March 2022
Resolved
Placards containing instructions for the donning and use of life jackets must be posted. Several life jackets onboard were of a different type than the placard showed. Swap for same-type life jackets or add placard.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: swapped for same kind of life jacket
08 - Alarms › N/A - No Subsystem › General alarm
Issued 2 March 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary. Loose bilge alarm wire was found in electrical compartment. Reattach loose wire.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: wire secured
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2022
Resolved
An exposed hazard must be properly protected by a cover, guard or rail. Rotating machinery in engine compartment was not covered. Install guard or cover.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: guard installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2022
Resolved
Electrical equipment exposed to weather must be watertight. Spaces where removed gauges were once placed were still open and exposed electrical installations to excess water/humidity. Make helm station watertight.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: Made watertight
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 March 2021
Resolved
An exposed hazard, such as gears or rotating machinery must be properly protected by a cover.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2021
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 February 2021
Resolved
Disposable hydrostatic release for EPIRB found to be expired, replace with new hydrostatic release.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 February 2021
Resolved
Each vessel must be equiped with at least two operable portable battery lights. Vessel only provided one light for Marine Inspection. An additional light needs to be added to the vessel.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2021
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 4 February 2020
Resolved
Forward bilge pump inoperable. Repair or replace and make operable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2020
Resolution: Bilge pump repaired and demonstrated fully operable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 February 2020
Resolved
Replace lifejacket instruction placard and properly post/provide.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 4 February 2020
Resolution: Lifejacket instruction placard replaced and posted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2020
Resolved
Replace wire for bilge pump. Wires found corroded. Ensure properly mounted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 4 February 2020
Resolution: Wire replaced and remounted.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 February 2020
Resolved
Replace first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 4 February 2020
Resolution: First aid kit replaced.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 4 February 2020
Resolved
Garbage placard found unreadable. Replace and post.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 4 February 2020
Resolution: Garbage placard replaced and posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 February 2020
Resolved
Ring life buoy light found inoperable. Repair or replace.
Action required: 10 - Deficiency Rectified
Resolved 4 February 2020
Resolution: Ring lift buoy light battery was replaced and light was demonstrated operable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2019
Resolved
First Aid kit must have all required items in accordance with 46 CFR 160.041 and not expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 12 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 March 2019
Resolved
EPIRB battery must be replaced due to its battery expiring.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 12 March 2019
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 March 2019
Resolved
Guards must be placed over rotating belts on the engine.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 12 March 2019
Communications › Radio Communications › VHF Radiotelephone
Issued 26 February 2018
Resolved
Replace VHF radio with GPS capable or link GPS to existing one, program MMSI number.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 23 March 2018
Resolution: MMSI number programmed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 February 2018
Resolved
Replace expired battery on lifebuoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 23 March 2018
Resolution: Battery on lifebuoy renewed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 February 2018
Resolved
Properly separate child and adult life jacekts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 23 March 2018
Resolution: Child and adult life jackets seperated.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 February 2018
Resolved
Fix port side nav light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 23 March 2018
Resolution: Port navigation light repaired.
Communications › Radio Communications › VHF Radiotelephone
Issued 26 February 2018
Resolved
Properly document daily radio checks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 23 March 2018
Resolution: Radio checks documented properly.
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 February 2018
Resolved
Conduct and appropriately document drills and crew training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 23 March 2018
Resolution: Drills conducted and logged IAW 46 CFR 185.420(c).
Navigation › Piloting/Steering › Marine Charts
Issued 26 February 2018
Resolved
Provide current or update charts for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 23 March 2018
Resolution: Obtained corrected charts.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 2 February 2017
Resolved
Fire equipment onboard has not had its annual inspection and is expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2017
Resolved 1 March 2017
Resolution: Fire equipment on board was mounted and inspected satisfactory.
Engineering › Bilge Water Management System › Not Installed
Issued 2 February 2017
Resolved
Label switches and high water alarms in spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 2 February 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 February 2017
Resolved
Remove old COI sticker.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 2 February 2017
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 2 February 2017
Resolved
Check parasail gear equipment, not on board during inspection.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 1 March 2017
Resolution: Parasail gear was inspected and paper work provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 February 2016
Resolved
Vessel's VHF was experiencing intermittent problems getting channel 27, but was able to satisfactorily obtain radio checks locally. Requested a servicing report by 10 MAR 16.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 25 March 2016
Resolution: Owner provided documentation that radios were checked by FCC licensed technician.
Documentation › Logs/Records › Logbook (official)
Issued 25 February 2016
Resolved
Vessel logs were not onboard. Provide daily, EPIRB, and maintentance logs by 10MAR16.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 25 March 2016
Resolution: Logs provided.