ODYSSEA DEFENDER

ODYSSEA DEFENDER is a 2008 offshore supply vessel. The Coast Guard has recorded 17 inspections since 2016, most recently in December 2025, along with 11 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 10 December 2025.

Built
2008
Last inspected
10 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 December 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9535072
WDE7022
938971
Flag
UNITED STATES
Maury page id
psix-938971

Documentation record

Registered dimensions (L × B × D)180.0 ft × 40.0 ft × 15.0 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)180.0 ft × 40.0 ft × 15.0 ft
ITC tonnagegross 870 / net 261
BuilderBOLLINGER SHIPYARDS LOCKPORT LLC · LOCKPORT, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 31 March 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it870 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
261 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

10 December 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8273241
24 September 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8240323
30 January 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8070967
5 December 2023 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7828253
15 November 2023 Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7825105
22 December 2022 Administrative Inspection · Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7610794
5 January 2022 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7375850
10 December 2021 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7366115
21 January 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7127834
5 February 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6903097
28 November 2018 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6588043
15 November 2018 Internal Structural Exam · Hull Examination · Cargo Tank Internal · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6581170
2 April 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6383550
11 January 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6336045
17 November 2016 Periodic Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6043563
14 November 2016 Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6046166
4 February 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5828341

Deficiency record · 11

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 December 2022 Resolved
Electrical equipment on a vessel must be maintained to protect crew members, offshore workers and the vessel from electrical hazards. E/R exhaust fan in overhead in front of port main engine is soaked in oil. Replace/clean exhaust fan motor, winding, and associated pipiing free from all oil residue.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2023
Resolved 3 January 2023
Resolution: Received photos showing fan was removed and cleaned.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 22 December 2022 Resolved
Each vessel must be operated in compliance with Section 311 of the FWPCA. Engine room bilges have approx 100 gallons of oily water in bilge. Remove oily water and clean bilges free of oily waste.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2023
Resolved 3 January 2023
Resolution: Bilge water properly removed and disposed of.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 December 2022 Resolved
Suitable hand covers must be installed on each hot surface. Missing/improperly installed exhaust lagging on port main engine. Place exhaust lagging to prevent crew from coming into contact with hot surfaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2023
Resolved 3 January 2023
Resolution: Exhaust lagging was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 December 2022 Resolved
Except as provided by this part, the installation of machinery must comply with Subchapter F. Fire pump and motor are mis-aligned with broken lovejoy coupling. Repaired on the spot.
Action required: 10 - Deficiency Rectified
Due 22 December 2022
Resolved 22 December 2022
Resolution: Pump and motor were realigned and tested satisfactorily
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 December 2022 Resolved
Except as provided in paragraph c of this section, ventilator openings shall be provided with efficient weathertight closing appliance. Engine room ventilator closure on main deck would not close and dog tightly. Crew used equipment onboard to bend the closure into correct position.
Action required: 10 - Deficiency Rectified
Due 22 December 2022
Resolved 22 December 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 December 2022 Resolved
Electrical equipment on a vessel must be maintained to protect crewmembers from hazards. Battery acid present iand pooling in battery box for generators. Clean battery box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2023
Resolved 3 January 2023
Resolution: Battery box was cleaned and freed of acid
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 November 2016 Resolved
Prove proper operation of rudder indicators. The forward and aft pilot house stations show 23 port for max, the indicated in the E/R indicates 23 STBD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2016
Resolved 22 November 2016
Resolution: Attend vessel verified proper operation.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 17 November 2016 Resolved
Vessel is 870 ITC and does not have an approved Non Tank vessel response plan. Plan was submitted 17NOV2016. Provide approval letter within 30 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 1 December 2016
Resolution: NT vessel response plan approval letter verified dated 01DEC2016.
Engineering › Fuel Oil Service System › Filter
Issued 17 November 2016 Resolved
Generators fuel strainers are plastic and do not meet ASTM F 1201. Install Cummins retro fit kit to meet standard.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2016
Resolved 22 November 2016
Resolution: Attended vessel verified plastic removed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 November 2016 Resolved
E-lighting at port and starboard life rafts inoperable. Prove proper operation to attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2016
Resolved 22 November 2016
Resolution: Attended vessel tested e-lights.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 17 November 2016 Resolved
Missing electrical matting behind switchboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 17 November 2016
Resolution: Matting was replaced prior to completion of inspection.