NFE ZERO is a 2009 offshore supply vessel. The Coast Guard has recorded 16 inspections since 2010, most recently in April 2021, along with 14 deficiencies and 5 casualty investigations between 2010 and 2019.

Records from 2010 to 2021. Most recent: inspection, 7 April 2021.

Built
2009
Last inspected
7 April 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9418523 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
938973
Flag
VANUATU
368503000 (licence lapsed)
Maury page id
psix-938973

Inspections, by type

…with no type recorded3
Years with a record 8 calendar years (2010–2021)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it2326 - Convention (Subpart B), Gross Ton
3640 - Dead Weight, Metric Ton
5380 - Displacement, Metric Ton
697 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WQAUMMSI 368503000 · cancelled · compulsorily equipped · granted 11 May 2016, cancelled 11 May 2023
WQAUMMSI 368503000 · terminated · compulsorily equipped · granted 24 April 2013, cancelled 11 May 2016
WQAUMMSI 368503000 · terminated · compulsorily equipped · granted 1 October 2009, cancelled 24 April 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TRANSOCEAN MARIANAS Mobile Offshore Drilling Unit · MISLE 452969 · 10 March 2010 · activity 3910656

Inspection history · 16

7 April 2021 PSC A
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7170287
23 December 2019 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6878260
19 December 2019 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6876924
18 December 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6877279
19 March 2019 Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6665329
28 February 2018 ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6363039
11 January 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6336573
8 March 2017 ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6101368
10 March 2016 Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6348588
3 October 2014 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5001362
19 March 2014 Administrative Inspection · ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4819166
28 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4476649
23 May 2012 Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4320099
18 February 2012 Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification · DAPI Audit
Physical examination · Activities Europe · Activity 4232757
3 November 2010 ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3883781
10 March 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3910656

Deficiency record · 14

11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 April 2021 Resolved
LIFE RAFTS SHALL BE STOWED AS TO PERMIT MANUAL RELEASE OF ONE RAFT OR CONTAINER AT A TIME FROM THEIR SECURING ARRANGEMENTS. SHIPS MANUAL RELEASE ARRANGEMENTS FOR BOTH PORT AND STARBOARD LIFE RAFTS WERE NOT IN PLACE AT THE LIFE RAFT LAUNCHING STATION. 74 SOLAS 2014 CONS CH III REG 13.4.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Vessel properly installed manual release mechanisms IAW class guidelines.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 April 2021 Resolved
SHIP SHALL BE DESIGNED, CONSTRUCTED, AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY WHICH IS RECOGNIZED BY THE ADMINISTRATION. WATERTIGHT DOOR ENTERING THE STEERING GEAR ROOM WAS MISALIGNED COMPROMISING WATERTIGHT INTEGRITY. 74 SOLAS 2004 CONS CH II-1 REG 3-1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Vessel repaired and re installed WTD. Class verified installation.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 April 2021 Resolved
THE EMERGENCY SOURCE OF ELECTRICAL POWER SHALL BE CAPABLE, HAVING REGARD TO STARTING CURRENTS AND THE TRANSITORY NATURE OF CERTAIN LOADS, OF SUPPLYING SIMULTANEOUSLY AT LEAST THE FOLLOWING SERVICES FOR THE PERIODS SPECIFIED HEREINAFTER, IF THEY DEPEND UPON AN ELECTRICAL SOURCE FOR THEIR OPERATION. WHERE THE EMERGENCY SOURCE OF ELECTRICAL POWER IS AN ACCUMULATOR BATTERY IT SHALL BE CAPABLE OF IMMEDIATELY SUPPLYING AT LEAST THOSE SERVICES SPECIFIED IN PARAGRAPH 4. SHIPS BRIDGE EMERGENCY ACCUMLATOR BATTERIES LOCATED BELOW THE NAVIGATION BRIDGE WERE NOT CONNECTED TO THE CIRCUT. 74 SOLAS 2004 CONS CH II-1 REG 43.3.2.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Vessel installed batteries IAW class guidelines and verified by Class after installation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2021 Resolved
THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD WORKING ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: FIRE DETECTION AND FIRE ALARM SYSTEM. SHIP WAS MISSING 02 PROTECTIVE HOUSINGS FOR SMOKE DETECTORS IN THE ENGINE ROOM. 74 SOLAS 2009 CONS CH II-2 REG 14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Smoke Detectors were properly installed with a necessary equipment. Class Attested.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 8 April 2021 Resolved
A RECORD SHALL BE KEPT, TO THE SATISIFACTION OF THE ADMINISTRATION AND AS REQUIRED BY THE RADIO REGULATIONS, OF ALL INCIDENTS CONNECTED WITH THE RADIO COMMUNICATION SERVICES WHICH APPEAR TO BE OF IMPORTANCE TO SAFETY OF LIFE AT SEA. SHIPS WAS NOT FOLLOWING THE FUNCTIONAL ADMINISTRATION REQUIREMENTS OF THE GLOBAL MARITIME DISTRESS AND SAFETY SYSTEM BY NOT LOGGING DAILY, WEEKLY, AND MONTHLY TESTS SINCE THE VESSEL HAS BEEN OPERATING. 74 SOLAS 2020 CONS CH IV REG 17
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Ship begun making the correct entries into the GMDSS Logbook. Class attested on behalf of flag.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 April 2021 Resolved
ESCAPE ROUTES SHALL BE MAINTAINED IN A SAFE CONDITION, CLEAR OF OBSTACLES. SHIPS STEERING GEAR ROOM HAD NUMEROUS ITEMS STOWED ON DECK THAT INTERFERED WITH THE MEANS OF ESCAPE. 74 SOLAS CONS 2009 CH II-2 REG 13.1.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Ship relocated items in the steering gear room to an appropriate stowage location that did not interfere with means of escape. Class Attested.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 April 2021 Resolved
THE PURPOSE OF THIS REGULATION IS TO PROVIDE MEANS OF ESCAPE SO THAT PERSONS ONBOARD CAN SAFELY AND SWIFTLY ESCAPE TO THE LIFEBOAT AND LIFE RAFT EMBARKATION DECK. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET ADDITIONAL AIDS FOR ESCAPE SHALL BE PROVIDED AS NECESSARY TO ENSURE ACCESSIBILITY, CLEAR MARKING, AND ADEQUATE DESIGN FOR EMERGENCY SITUATIONS. SHIP DID NOT HAVE EMERGENCY ESCAPE AIDS TO SAFELY NAVIGATE PERSONNEL FROM THE STEERING GEAR ROOM TO THE EMBARKATION DECK. 74 SOLAS 2009 CONS CH II-2 REG 13.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Emergency escape aids installed IAW with the fire control plan and lifesaving plan. Class Attested.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 April 2021 Resolved
GENERAL ARRANGEMENT PLANS SHALL BE PERMANENTLY EXHIBITED FOR THE GUIDANCE OF THE SHIP’S OFFICERS, SHOWING CLEARLY FOR EACH DECK THE CONTROL STATIONS, THE VARIOUS FIRE SECTIONS ENCLOSED BY "A" CLASS DIVISIONS, THE SECTIONS ENCLOSED BY "B" CLASS DIVISIONS TOGETHER WITH PARTICULARS OF THE FIRE DETECTION AND FIRE ALARM SYSTEMS, THE SPRINKLER INSTALLATION, THE FIRE-EXTINGUISHING APPLIANCES, MEANS OF ACCESS TO DIFFERENT COMPARTMENTS, DECKS, ETC., AND THE VENTILATING SYSTEM INCLUDING PARTICULARS OF THE FAN CONTROL POSITIONS, THE POSITION OF DAMPERS AND IDENTIFICATION NUMBERS OF THE VENTILATING FANS SERVING EACH SECTION. SHIP WAS MISSING 02 SMOKE DETECTOR PLACARDS IN THE ENGINE ROOM, 01 HEAT DETECTOR PLACARD IN THE EMERGENCY GENERATOR SPACE, AND 04 SPACE OR GROUP OF SPACES PROTECTED BY FIRE-EXTINGUISHING SYSTEM PLACARDS AT THE ENTRANCES TO THE ENGINE ROOM. 74 SOLAS 2009 CONS CH II-2 REG 15.2.4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Ship installed proper placards IAW Fire Control Plan. Class attested.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 April 2021 Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. 01 LIGHT FIXTURE IN THE SHIPS ENGINE ROOM WAS FOUND TO BE IN A LESS THAN SAFE FROM ELECTRICAL HAZARDS CONDITION. LIGHTING FIXTURE IN THE ENGINE ROOM WAS FOUND WITH A BURN HOLE IN THE PROTECTIVE COVERING. LIGHTING FIXTURE WAS FOUND NOT PROPERLY INSTALLED IN ITS INTENDED BRACKET. 74 SOLAS 2004 CONS CH II-1 REG 40.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Vessel installed corrected light fixture to satisfy electrical hazard requirements. Class attested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 April 2021 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. SHIPS EMERGENCY AIR RECEIVER DID NOT HAVE A PROPERLY OPERATING PRESSURE GAUGE. 74 SOLAS 2004 CONS CH I REG 11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 14 April 2021
Resolution: Ship installed properly operating air receiver pressure gauge. Class Attested.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 8 April 2021 Resolved
IN EVERY CASE, THE ADMINISTRATION CONCERNED SHALL FULLY GUARANTEE THE COMPLETENESS AND EFFICIENCY OF THE SURVEY AND SHALL UNDERTAKE TO ENSURE THE NECESSARY ARRANGEMENTS TO SATISFY THIS OBLIGATION. SHIPS INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE WAS MISSING THE THROUGHPUT OF THE OILY WATER SEPARATOR SATISFYING THE MEPC. 107 STANDARD MARPOL 73/76 2011 CONS ANNEX 1 REG 6.3.4
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 14 April 2021
Resolution: Class reviewed the supporting documentation to support the OWS Throughput. Class attested.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 February 2012 Resolved
Owner / Operator / ISM Company names do no coordinate betwee COD, COI, ISSC, SMC, DOC & CSR. Review documents and apply for changes as appropriate by 18 Mar 12.
Action required: 705 - Other - as specified
Due 18 February 2012
Resolved 30 May 2012
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 18 February 2012 Resolved
Prove repair of exhaust leak on starboard main engine inboard turbo charger by 18 MAR 12.
Due 18 February 2012
Resolved 11 March 2012
Resolution: confirmation and photos via email dated 11 March 12 from Chris Jones, vsl manager for satifactory repairs.
Documentation › Certificates/Documents › IOPP Certificate
Issued 18 February 2012 Resolved
Prove receipt of IOPP Form A by 18 MAR 12. Form B was issued by ABS in Brazil because the Brazilian administration views OSV's as tank ships.
Due 18 March 2012
Resolved 1 March 2012
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]

Casualty record · 5

10 March 2010Routine · role: Involved in a Marine Casualty · 1 injured · activity 3910656
7 March 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4546872
14 July 2013Routine · role: Involved in a Marine Casualty · activity 4653779
3 October 2014Routine · role: Acknowledged Pollution Source · activity 5001362
18 December 2019Routine · role: Involved in a Marine Casualty · activity 6877279
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

TERREL TIDE (2010–2019). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.