Records from 2010 to 2021. Most recent: inspection, 7 April 2021.
Inspection history · 16
7 April 2021
PSC A
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7170287
23 December 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6878260
19 December 2019
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6876924
18 December 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6877279
19 March 2019
Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6665329
28 February 2018
ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6363039
11 January 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6336573
8 March 2017
ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6101368
10 March 2016
Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6348588
3 October 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5001362
19 March 2014
Administrative Inspection · ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4819166
28 May 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4476649
23 May 2012
Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4320099
18 February 2012
Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification · DAPI Audit
Physical examination · Activities Europe · Activity 4232757
3 November 2010
ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3883781
10 March 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3910656
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 April 2021
Resolved
LIFE RAFTS SHALL BE STOWED AS TO PERMIT MANUAL RELEASE OF ONE RAFT OR CONTAINER AT A TIME FROM THEIR SECURING ARRANGEMENTS. SHIPS MANUAL RELEASE ARRANGEMENTS FOR BOTH PORT AND STARBOARD LIFE RAFTS WERE NOT IN PLACE AT THE LIFE RAFT LAUNCHING STATION.
74 SOLAS 2014 CONS CH III REG 13.4.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Vessel properly installed manual release mechanisms IAW class guidelines.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 April 2021
Resolved
SHIP SHALL BE DESIGNED, CONSTRUCTED, AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY WHICH IS RECOGNIZED BY THE ADMINISTRATION. WATERTIGHT DOOR ENTERING THE STEERING GEAR ROOM WAS MISALIGNED COMPROMISING WATERTIGHT INTEGRITY.
74 SOLAS 2004 CONS CH II-1 REG 3-1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Vessel repaired and re installed WTD. Class verified installation.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 April 2021
Resolved
THE EMERGENCY SOURCE OF ELECTRICAL POWER SHALL BE CAPABLE, HAVING REGARD TO STARTING CURRENTS AND THE TRANSITORY NATURE OF CERTAIN LOADS, OF SUPPLYING SIMULTANEOUSLY AT LEAST THE FOLLOWING SERVICES FOR THE PERIODS SPECIFIED HEREINAFTER, IF THEY DEPEND UPON AN ELECTRICAL SOURCE FOR THEIR OPERATION. WHERE THE EMERGENCY SOURCE OF ELECTRICAL POWER IS AN ACCUMULATOR BATTERY IT SHALL BE CAPABLE OF IMMEDIATELY SUPPLYING AT LEAST THOSE SERVICES SPECIFIED IN PARAGRAPH 4. SHIPS BRIDGE EMERGENCY ACCUMLATOR BATTERIES LOCATED BELOW THE NAVIGATION BRIDGE WERE NOT CONNECTED TO THE CIRCUT.
74 SOLAS 2004 CONS CH II-1 REG 43.3.2.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Vessel installed batteries IAW class guidelines and verified by Class after installation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2021
Resolved
THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD WORKING ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: FIRE DETECTION AND FIRE ALARM SYSTEM. SHIP WAS MISSING 02 PROTECTIVE HOUSINGS FOR SMOKE DETECTORS IN THE ENGINE ROOM.
74 SOLAS 2009 CONS CH II-2 REG 14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Smoke Detectors were properly installed with a necessary equipment. Class Attested.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 8 April 2021
Resolved
A RECORD SHALL BE KEPT, TO THE SATISIFACTION OF THE ADMINISTRATION AND AS REQUIRED BY THE RADIO REGULATIONS, OF ALL INCIDENTS CONNECTED WITH THE RADIO COMMUNICATION SERVICES WHICH APPEAR TO BE OF IMPORTANCE TO SAFETY OF LIFE AT SEA. SHIPS WAS NOT FOLLOWING THE FUNCTIONAL ADMINISTRATION REQUIREMENTS OF THE GLOBAL MARITIME DISTRESS AND SAFETY
SYSTEM BY NOT LOGGING DAILY, WEEKLY, AND MONTHLY TESTS SINCE THE VESSEL HAS BEEN OPERATING.
74 SOLAS 2020 CONS CH IV REG 17
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Ship begun making the correct entries into the GMDSS Logbook. Class attested on behalf of flag.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 April 2021
Resolved
ESCAPE ROUTES SHALL BE MAINTAINED IN A SAFE CONDITION, CLEAR OF OBSTACLES. SHIPS STEERING GEAR ROOM HAD NUMEROUS ITEMS STOWED ON DECK THAT INTERFERED WITH THE MEANS OF ESCAPE.
74 SOLAS CONS 2009 CH II-2 REG 13.1.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Ship relocated items in the steering gear room to an appropriate stowage location that did not interfere with means of escape. Class Attested.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 April 2021
Resolved
THE PURPOSE OF THIS REGULATION IS TO PROVIDE MEANS OF ESCAPE SO THAT PERSONS ONBOARD CAN SAFELY AND SWIFTLY ESCAPE TO THE LIFEBOAT AND LIFE RAFT EMBARKATION DECK. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET ADDITIONAL AIDS FOR ESCAPE SHALL BE PROVIDED AS NECESSARY TO ENSURE ACCESSIBILITY, CLEAR MARKING, AND ADEQUATE DESIGN FOR EMERGENCY SITUATIONS. SHIP DID NOT HAVE EMERGENCY ESCAPE AIDS TO SAFELY NAVIGATE PERSONNEL FROM THE STEERING GEAR ROOM TO THE EMBARKATION DECK.
74 SOLAS 2009 CONS CH II-2 REG 13.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Emergency escape aids installed IAW with the fire control plan and lifesaving plan. Class Attested.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 April 2021
Resolved
GENERAL ARRANGEMENT PLANS SHALL BE PERMANENTLY EXHIBITED FOR THE GUIDANCE OF THE SHIP’S OFFICERS, SHOWING CLEARLY FOR EACH DECK THE CONTROL STATIONS, THE VARIOUS FIRE SECTIONS ENCLOSED BY "A" CLASS DIVISIONS, THE SECTIONS ENCLOSED BY "B" CLASS DIVISIONS TOGETHER WITH PARTICULARS OF THE FIRE DETECTION AND FIRE ALARM SYSTEMS, THE SPRINKLER INSTALLATION, THE FIRE-EXTINGUISHING APPLIANCES, MEANS OF ACCESS TO DIFFERENT COMPARTMENTS, DECKS, ETC., AND THE VENTILATING SYSTEM INCLUDING PARTICULARS OF THE FAN CONTROL POSITIONS, THE POSITION OF DAMPERS AND IDENTIFICATION NUMBERS OF THE VENTILATING FANS SERVING EACH SECTION. SHIP WAS MISSING 02 SMOKE DETECTOR PLACARDS IN THE ENGINE ROOM, 01 HEAT DETECTOR PLACARD IN THE EMERGENCY GENERATOR SPACE, AND 04 SPACE OR GROUP OF SPACES PROTECTED BY FIRE-EXTINGUISHING SYSTEM PLACARDS AT THE ENTRANCES TO THE ENGINE ROOM.
74 SOLAS 2009 CONS CH II-2 REG 15.2.4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Ship installed proper placards IAW Fire Control Plan. Class attested.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 April 2021
Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. 01 LIGHT FIXTURE IN THE SHIPS ENGINE ROOM WAS FOUND TO BE IN A LESS THAN SAFE FROM ELECTRICAL HAZARDS CONDITION. LIGHTING FIXTURE IN THE ENGINE ROOM WAS FOUND WITH A BURN HOLE IN THE PROTECTIVE COVERING. LIGHTING FIXTURE WAS FOUND NOT PROPERLY INSTALLED IN ITS INTENDED BRACKET.
74 SOLAS 2004 CONS CH II-1 REG 40.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 13 April 2021
Resolution: Vessel installed corrected light fixture to satisfy electrical hazard requirements. Class attested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 April 2021
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. SHIPS EMERGENCY AIR RECEIVER DID NOT HAVE A PROPERLY OPERATING PRESSURE GAUGE.
74 SOLAS 2004 CONS CH I REG 11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 14 April 2021
Resolution: Ship installed properly operating air receiver pressure gauge. Class Attested.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 8 April 2021
Resolved
IN EVERY CASE, THE ADMINISTRATION CONCERNED SHALL FULLY GUARANTEE THE COMPLETENESS AND EFFICIENCY OF THE SURVEY AND SHALL UNDERTAKE TO ENSURE THE NECESSARY ARRANGEMENTS TO SATISFY THIS OBLIGATION. SHIPS INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE WAS MISSING THE THROUGHPUT OF THE OILY WATER SEPARATOR SATISFYING THE MEPC. 107 STANDARD
MARPOL 73/76 2011 CONS ANNEX 1 REG 6.3.4
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 14 April 2021
Resolution: Class reviewed the supporting documentation to support the OWS Throughput. Class attested.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 February 2012
Resolved
Owner / Operator / ISM Company names do no coordinate betwee COD, COI, ISSC, SMC, DOC & CSR. Review documents and apply for changes as appropriate by 18 Mar 12.
Action required: 705 - Other - as specified
Due 18 February 2012
Resolved 30 May 2012
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 18 February 2012
Resolved
Prove repair of exhaust leak on starboard main engine inboard turbo charger by 18 MAR 12.
Due 18 February 2012
Resolved 11 March 2012
Resolution: confirmation and photos via email dated 11 March 12 from Chris Jones, vsl manager for satifactory repairs.
Documentation › Certificates/Documents › IOPP Certificate
Issued 18 February 2012
Resolved
Prove receipt of IOPP Form A by 18 MAR 12. Form B was issued by ABS in Brazil because the Brazilian administration views OSV's as tank ships.
Due 18 March 2012
Resolved 1 March 2012
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]