Records from 2016 to 2026. Most recent: inspection, 2 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.0 ft
Registered tonnagegross 9 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGEO SHIPYARD INC · NEW IBERIA, LA, UNITED STATES · built 2008
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
18 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
2 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8327622
25 March 2026
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8320518
6 May 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8129210
3 April 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7886870
13 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7876092
6 June 2023
Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7692183
3 March 2022
Drydock Exam · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7404754
22 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7232515
13 February 2020
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6895077
14 March 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6642475
3 May 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6404244
15 February 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6348619
30 May 2017
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 6161152
4 November 2016
Simplified Stability Test · COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6038389
3 May 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5865485
28 April 2016
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 5865204
18 February 2016
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 5818003
10 February 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5812571
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 May 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must be capable of manual actuation from outside the space.
Vessel was not equipped with manual actuation for the pre-engineered fixed gas fire extinguishing system located outside the protected space.
46 CFR 181.420(a)(2)
17c
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2025
Resolution: Vessel rep installed the new fireboy with the correct nozzle which supports manual actuation. System was installed per manufacturer's specifications. Verified in person by MI.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 6 June 2023
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have an audible alarm that sounds upon discharge at the operating station. Installed system did not have an audible alarm during activation test. Repair/renew.
46 CFR 181.420 (b)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 23 June 2023
Resolution: Conducted repairs to the system; alarm is functional.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2023
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Properly mark valves.
46 CFR 185.608
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 23 June 2023
Resolution: Properly Marked.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 6 June 2023
Resolved
Rails of equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Installed rails were found cracked along the welds at the base throughout the vessel Conduct needed repairs.
46 CFR 177.900(a)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 23 June 2023
Resolution: Rails rewelded.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 3 May 2018
Resolved
Documentation shall be provided to show that lifesaving equipment checks are being conducted.
Action required: 705 - Other - as specified
Due 3 June 2018
Resolved 14 March 2019
Resolution: Vessel has completed lifesaving maintenance and logged the maintenance in accordance with applicable regulations.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 3 May 2018
Resolved
Vessel does not have required fire supression system for gasoline tank storage room. Provide installed or pre-engineered fire supression system.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2018
Resolved 13 June 2018
Resolution: Inspected completed installation of fireboy system.
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 2 March 2017
Resolved
Remove portable gasoline canisters used to refill generator prior to operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2017
Resolved 2 March 2017
Resolution: Portable tanks were removed satisfactorily.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 2 March 2017
Resolved
Prior to operation, provide corrected charts and publications. Currently unable to verify corrections.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2017
Resolved 2 March 2017
Resolution: Vessel provided new corrected charts.
Stability › Intact Stability (when using lifting gear) › General
Issued 9 November 2016
Resolved
When necessary for safe operation, the cognizant OCMI may place specific stability estrictions on a stability letter or COI. OCMI determined the Simplified Stability test on the sister ship [name withheld], Official Number: 1210014 was conducted on a protected route. The vessel operates on a partially protected route.
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 15 December 2016
Resolution: Completed SST. All sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 November 2016
Resolved
Unable to verify record of conducted drills. Complete man overboard drill prior to carrying passengers. Email statement/log book entry to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2017
Resolved 17 March 2017
Resolution: Owner's rep provided proof of man overboard drill conducted on 16MAR17.
Fire Fighting › Ventilation Systems › Fans
Issued 4 November 2016
Resolved
Currently there is no mechanical exhaust ventilation in space with gasoline fuel tank. No prohibitions at this time, will clarify with local OCMI regarding installation.
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 9 March 2017
Resolution: Vessel meets ABYC H-2 standards and does not require mechanical ventilation in the space.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 3 May 2016
Resolved
Provide proper visual indicator at operators station for the forward bilge level alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 10 May 2016
Resolution: Visual bilge alarm at operators station demonstrated to inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 May 2016
Resolved
All electrical equipment in spaces containing gasoline fuel tanks shall be explosion-proof, intrinsically safe, or ignition protected. Make all electrical equipment meet requirement prior to embarking passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2016
Resolved 10 May 2016
Resolution: Wire connections moved outside of space and ignition protected electic bilge pump installed. Pump/alarm test satisfactory.
Construction/Loadline › Structures › Ventilators
Issued 3 May 2016
Resolved
Aft Fuel tank compartment lacks proper ventilation for a space containing gasoline fuel tanks. Provide repair proposal to properly ventilate space prior to embarking passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2016
Resolved 10 May 2016
Resolution: Builder confirmed vessel built to ABYC H-2 standard which does not require ventilation in spaces with metal gas tanks. Existing ventilation is in excess of requirement. Cleared def.