Records from 2008 to 2026. Most recent: inspection, 14 April 2026.
Inspection history · 37
14 April 2026
Internal Structural Exam · Vessel Attendance · Deficiency Check · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8350961
5 March 2026
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8320050
4 February 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8074459
2 February 2024
MTSA Verification · Deficiency Check · Periodic Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7859565
22 February 2023
Deficiency Check · Internal Structural Exam · Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7640767
27 October 2021
COI Inspection · Cargo Tank Internal · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7337600
23 September 2021
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7318730
24 June 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7234641
21 January 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7128484
30 July 2019
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6767034
15 December 2018
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6601437
11 May 2018
Cargo Tank Internal · Drydock Exam · COI Inspection · MARPOL Annex VI Survey · Internal Structural Exam · MARPOL Annex II Examination · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6411784
11 December 2017
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6322565
2 March 2017
MTSA/ISPS Verification · MARPOL Annex II Examination · MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6097515
4 January 2017
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6068222
14 July 2016
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5941445
24 May 2016
MTSA Verification · MARPOL Annex VI Survey · MARPOL Annex II Examination · MARPOL Annex I Examination · Deficiency Check · Internal Structural Exam · Periodic Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5885767
20 July 2015
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5190602
10 July 2014
MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex II Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4916505
24 March 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4821735
24 August 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4817674
3 December 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4495164
19 July 2012
MTSA Verification · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4383616
12 April 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4294877
12 October 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4166257
12 September 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4143350
20 July 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4088421
13 May 2010
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3737090
13 May 2010
MARPOL Annex I Examination · Deficiency Check · MARPOL Annex VI Survey · MTSA Verification · Annual Inspection · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3747230
8 April 2010
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3711855
5 August 2009
Deficiency Check · MTSA Verification · MARPOL Annex V Examination · MARPOL Annex II Examination · MARPOL Annex I Examination · Annual Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3514415
31 July 2009
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3551778
31 July 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3560896
18 April 2009
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3457469
27 March 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3441374
31 October 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3354987
14 March 2008
Administrative Inspection · Initial Certification · Initial Construction-Excluding Oversight · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3164698
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2026
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. MI observed that no EAP hotline or information placard was displayed in crew area.
46 CFR 16.401(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2026
Resolution: Objective evidence submitted, see documents activity documents tab for details.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2026
Resolved
An EAP training program must be conducted for the employer's crew members and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crew members and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. MI observed that no records could be produced to show employee training nor supervisory personnel training.
46 CFR 16.401(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2026
Resolution: Objective evidence submitted, see documents activity documents tab for details.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 March 2026
Resolved
A vessel owner or operator required to have a response plan shall conduct exercise as necessary to ensure that the plan will function in an emergency. Both announced and unannounced exercises must be included. The minimum exercises required include: qualified individual notification exercise (quarterly), emergency procedures exercises (quarterly), shore-based spill management team table top exercises (annually), oil spill removal organization equipment deployment exercises (annually). MI observed that no records of exercises could be produced.
33 CFR 155.1060 (a)(1) – (5)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2026
Resolution: Objective evidence submitted, see documents activity documents tab for details.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 March 2026
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. MI observed that the painter line on the life raft was not attached to the weak link.
46CFR199.190(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2026
Resolution: Objective evidence submitted, see documents activity documents tab for details.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 5 March 2026
Resolved
Each EPIRB and each SART, other than an EPIRB or SART in an inflatable life raft, must be tested monthly. MI observed that no record could be produced showing EPIRB testing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2026
Resolution: Objective evidence submitted, see documents activity documents tab for details.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 5 March 2026
Resolved
Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open. MI observed that cargo pump relief valves were last tested Nov 2023.
46CFR35.35(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2026
Resolution: Witnessed testing of cargo pump relief valves. Both valves relieved at a hydrostatic pressure of 125psi.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 4 February 2025
Resolved
The tank overfill alarm required by paragraph (a) of this section must - activate a visible and audible alarm so that is can be seen and heard on the vessel where cargo transfer is controlled in the cargo deck area. Overfill alarm #4P was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 March 2025
Resolution: Vessel rep installed new high level alarm system panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 February 2025
Resolved
Each deck box must be weather tight. The battery box for the #1 cargo pump was damaged exposing the battery to weather conditions. Replace with a new battery box.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2025
Resolution: Replaced Battery Box.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 February 2025
Resolved
Each life jacket must be marked in block capital letters with the name of the vessel. Life jackets were found to have previous name of vessel legible. Remove previous vessel name.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2025
Resolution: Replaced life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 4 February 2025
Resolved
Each liferaft or group of liferafts must be arranged for float-free launching. The arrangement must ensure that the liferaft or liferafts, when released and inflated, are not dragged under by the sinking vessel. A hydrostatic release unit used in a float-free arrangement must be approved under approval series 160.162.
Life rafts hydrostatic release is expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2025
Resolution: Installed new hydrostatic release.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 4 February 2025
Resolved
A mechanical means of closing each drain and scupper within the coaming. Vessel is missing mechanical scupper plugs in deck containment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2025
Resolution: Vessel rep installed all new mechanical scupper plugs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 4 February 2025
Resolved
Cargo pump pressure gauges shall be tested at least once a year for accuracy. Cargo pressure gauges have not been tested since 2023.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2025
Resolution: Calibrated cargo pump pressure gauges.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 4 February 2025
Resolved
Each hose must be marked with one of the following: (1) The name of each product for which the hose may be used. (2) For oil products, the words "OIL SERVICE" or (3) For hazardous materials, the words "HAZMAT SERVICE - SEE LIST" followed immediately by a letter, number or other symbol that corresponds to a list or chart contained in the facility's operations manual or vessels transfer procedures documents. Each hose must also be marked with the following. (1) Max allowable working pressure (2) Date of manufacture; and (3) Date of latest test required by 33 CFR 156.70
Hoses were not labeled IAW 33 CFR 154.500
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2025
Resolution: Hoses were adequately marked.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 February 2024
Resolved
The terms, endorsements and conditions set forth on a certificate of inspection shall have the same force and effect as the regulations contained in this subchapter.
Vessel is permissively manned and escape hatch from berthing area is in operable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2024
Resolution: Freed up and serviced hatch.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2024
Resolved
The following locations in the weather are Class I, Division 1 (Zone 1) locations (except the open deck area on an inorganic acid carrier which is considered a non-hazardous location) and may have only approved intrinsically safe, explosionproof, or purged and pressurized electrical equipment, and through runs of marine shipboard cable if the location.
Multiple yard electrical boxes and extension cords are located in hazardous zone.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2024
Resolution: Removed equipment from the barge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2024
Resolved
There must be ground detection for each: (a) Electric propulsion system; (b) Ship's service power system; (c) Lighting system.
Ground detection on inboard lighting panel was not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 1 April 2024
Resolution: Deficiency rectified
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2024
Resolved
In general, connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable.
open wire present by inboard battery charger.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 28 February 2024
Resolution: properly terminated the open wire.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 7 February 2024
Resolved
General Alarm must Be audible in the spaces identified in paragraph (a) of this section with all normally closed doors and accesses closed.
GE alarm bell was not working in generator room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 28 February 2024
Resolution: GE alarm made operational
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 February 2024
Resolved
Rules in this subpart (Rules 20–31) (§§ 83.20 through 83.31) shall be complied with in all weathers.
Bow and stern lights are extinguished, limited to fair weather and day time operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 February 2024
Resolution: Replaced bulbs on extiguised lights
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 February 2024
Resolved
Lights in machinery spaces. Alternate groups of lights in an engineroom, boilerroom, or auxiliary machinery space must be arranged so that the failure of one branch circuit does not leave an area without light.
Light above switchboard was extinguished.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 1 April 2024
Resolution: Deficiency Rectified
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 February 2024
Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between boltholes, and in line with the bolthole pattern.
Missing stud on both port and stbd fwd facing vapor flanges.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 1 April 2024
Resolution: Studs in place. Deficiency rectified.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 22 February 2023
Resolved
The cargo discharge piping of all tank vessels shall be tested at least once each year for tightness, at the maximum working pressure. Cargo Manifold hydro test was not conducted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2023
Resolved 21 March 2023
Resolution: Vessel conducted hydro test of cargo line and hoses.
14 - Pollution Prevention › 141 - MARPOL Annex I › Load, unload & clean proc. for cargo sp.(tankers)
Issued 22 February 2023
Resolved
Activate an alarm once the cargo level reaches 95 percent of the tank capacity or higher, Activate a visible and audible alarm so that it can be seen and heard on the vessel where cargo transfer is controlled. Audible alarm for high level alarm did not operate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2023
Resolved 16 March 2023
Resolution: replaced alarm speaker. operational test satisfactory
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 February 2023
Resolved
Electric installations and electric equipment must be inspected at the inspection for certification and periodic inspection to determine mechanical and electrical condition and performance. Emergency light for switch board was extinguished.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2023
Resolved 16 March 2023
Resolution: elight bulb replaced operational test satisfactory
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 February 2023
Resolved
Containers must be stowed on or above the weather deck in locations designated by the master. Containers specified in paragraph (a)(1) of this section which do not exceed a capacity of five gallons may be stowed below the weather deck in a paint or lamp locker. Flammable items were stored in aft peak
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2023
Resolved 16 March 2023
Resolution: removed materials from the barge
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 February 2023
Resolved
These types of heat sensitive materials must not be used to contain flammable, combustible, or dangerous fluids, or for vital systems unless approved by the Marine Safety Center. Plastic buckets are being used to collect oil from crankcase vents on engine.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2023
Resolved 16 March 2023
Resolution: replaced with steel containers
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 22 February 2023
Resolved
Cargo pump pressure gage shall be tested at least once a year for accuracy. Gauges were not tested for accuracy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2023
Resolved 16 March 2023
Resolution: gauges are calibrated, certifcates onboard.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 22 February 2023
Resolved
For a Coast Guard-approved vessel VCS that began operating on or after July 23, 1990, the tank vessel owner or operator must submit plans, calculations, and specifications to the MSC for review and approval. Missing VECS approval letter
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 February 2023
Resolution: provided O/O with copy of the MSC letter from MISLE
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 22 February 2023
Resolved
The operators of each vessel and facility engaged in the transfer operation shall retain a signed copy of the declaration of inspection on board the vessel or at the facility for at least 1 month from the date of signature.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 February 2023
Resolution: O/O provided copy of DOI that was left on USNS SUPPLY.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2022
Resolved
Nonmetallic flexible hose may be used in lengths not exceeding 30 inches where flexibility is required.
Fuel supply and return lines exceeded 30" on the #2 generator.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 October 2021
Resolved
Each generator prime mover must have an overspeed device that is independent of the normal operating governor and adjusted so that the speed cannot exceed the maximum rated speed by more than 15%.
Was not able to test overspeed because of lack of knowledge by the crew. Submit plan to test with OEM.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 October 2021
Resolved
Each prime mover must shut down automatically upon loss of lubriating pressure to the generator bearings if the generator is directly couples to the engine.
Was not able to test overspeed because of lack of knowledge by the crew. Submit plan to test with OEM.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 January 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 October 2021
Resolved
Each space used for passengers or crew must be fitted with lighting that provides for safe habitable and working environment under normal conditions. Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space.
Emergency lighting was not operational in the machinery space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 January 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 January 2021
Resolved
Certificates of Inspection will be issued for a period of 5 years; COI deactivated on 21JAN21 due to missed periodic inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 May 2023
Resolved 19 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 July 2019
Resolved
The following documents was not on board for review at the time of inspection: EIAPP, STS plan,and Company exercise,
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 August 2019
Resolved 28 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2019
Resolved
120v ground detection is inoperable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2019
Resolved 27 August 2019
Resolution: Ground detection tested satisfactorily.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 July 2019
Resolved
Overfill alarm on #1 stbd tank is inoperable
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 14 August 2019
Resolved 27 August 2019
Resolution: Overfill device tested satisfactorily.
Engineering › Generator (propulsion/auxiliary-electric) › Generator Excitation Circuitry
Issued 11 May 2018
Resolved
O/O did not make available the necessary technician nor electronic program to complete the req'd overspeed shutdown test.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 18 June 2018
Resolution: Attending MI witnessed proper shutdowns of generators.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 11 May 2018
Resolved
Outboard Cargo Pump & Outboard GENSET were involved in a previous CASREP incident. Both pieces of equipment were taken out of service prior to the inspection.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 18 June 2018
Resolution: Attending MI witnessed proper operation of both the generator and cargo pump, as well as all necessary shutdowns.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 December 2017
Resolved
Masthead lights are within hazardous zone when mast is in the down position. Lights on mast are not proper rating to be in hazardous zone.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 30 June 2018
Operations/Management › Drills/Instruction › Fire
Issued 11 December 2017
Resolved
When musters are held, details of drills must be recorded in log book. Firefighting drills were not recorded.
Action required: 705 - Other - as specified
Due 11 December 2017
Resolved 11 December 2017
Resolution: Instruction was provided to crew.
Fire Fighting › Combustible Materials › Stowage
Issued 11 December 2017
Resolved
All paint lockers must be protected by a CO2, water spray, or clean agent fire extinguishing system. Aft peak contained several buckets of flammable material without fixed fire protecion in space.
Action required: 705 - Other - as specified
Due 11 December 2017
Resolved 11 December 2017
Resolution: All buckets of hyrdaulic oil were removed.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 3 June 2016
Resolved
Vapor line pressure gauges are required to be tested annually & must show pressure within 10 percent of the actual pressure. All four gauges were displaying different pressures and were not within 10 percent of the actual pressure.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 6 June 2016
Resolution: Gauges were originally improperly installed. Reattended vessel and verified all gauges were reading the same pressure and were accurate.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 June 2016
Resolved
Each lifesaving appliance must be in working order and ready for immediate use. The aft lifebuoy light was not functioning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 6 June 2016
Resolution: Light was replaced by operator and found in working condition by attending MI.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 3 June 2016
Resolved
Each pressure-vacuum relief valve must be equipped with a mechanism to check that it operates freely and does not remain in the open position. The lifting handle is missing on the #4S cargo tank pressure-vacuum relief valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 6 June 2016
Resolution: Operator installed a new handle for the lifting device which was verified by the attending MI.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 3 June 2016
Resolved
Portable CO2 extinguishers should be permanently mounted in approved brackets. The CO2 extinguisher in the accommodation space is not mounted. 46CFR34.05-10
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 10 June 2016
Resolution: The fire extinguisher has been mounted in an approved bracket.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 3 June 2016
Resolved
All engines shall be of the marine type and suitable for service in the marine environment. The rain guards on the exhaust piping from the cargo pump engines were severely corroded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 10 June 2016
Resolution: New rain guards have been installed on both cargo pump engine exhaust outlets.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 24 May 2016
Resolved
The marine inspector shall conduct such tests and inspections of auxiliary machinery & of its associated equipment as he feels necessary to check safe operation. The high jacket water temp alarm and shutdown on the STBD generator was unable to be tested.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 10 June 2016
Resolution: Received a technician's report attesting to the satisfactory testing and operation of the STBD generator's high jacket water temp alarm and shutdown.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 24 May 2016
Resolved
Electric installations on vessels must ensure protection of crew, other persons, & the vessel from electrical hazards. A ground was present on the 120V system. Cleared on the spot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 3 June 2016
Resolution: Cleared on the spot. The electrician isolated and repaired the grounded deck floodlight.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 21 July 2015
Resolved
Vessel is using the wrong bracket for Fire extinguisher #6. Vessel has placed a smaller extinguisher in a larger bracket which is secured with a nylon strap.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 August 2015
Resolved 4 August 2015
Resolution: Vessel Rep submitted email documentation showing that the correct extinguisher bracket is installed.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 21 July 2015
Resolved
Vessel must provide the correct ground detection device for the 120V system
Action required: 705 - Other - as specified
Due 21 August 2015
Resolved 4 August 2015
Resolution: Vessel Rep submitted email photo documentation showing that the appropriate ground detection has been installed on the 120v distribution panel.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 21 July 2015
Resolved
Vessel has a sheared off pin at the 12'Oclock position on the Port Vapor Control manifold connection as per 46 CFR 39.2001(j)
Action required: 705 - Other - as specified
Due 21 August 2015
Resolved 4 January 2016
Resolution: Vessel Rep emailed photo documentation showing that a new "12 o''clock" stud has been installed.
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 9 July 2014
Resolved
Replace severely chaffed non metallic flexible hoses as noted on #2 generator and cargo pump engines #1 and #2
Action required: 705 - Other - as specified
Resolved 11 July 2014
Resolution: Visually inspected newly installed high pressure fuel hoses in all locations.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 19 July 2012
Resolved
Vessel must obtain IAPP / have an IAPP survey prior to sailing foreign. (MARPOL ANNEX VI) - Prior to sailing foreign.
Action required: 705 - Other - as specified
Resolved 21 May 2013
Resolution: Completed IAPP survey without any deficiencies noted. All required samples, sampler and documentation was sat.
Construction/Loadline › Hull › Side Shell
Issued 31 July 2009
Resolved
Vessel sustained damage after alliding with the tug Marjorie McAllister. Vessel must make forward rake gas free and certified with Marine chemist certificate upon completion of discharges in Peekskill and Newburgh, NY. Barge Captain to ensure area of damage is checked atleast every four hours for presence of water and further damage.
Action required: 705 - Other - as specified
Due 5 August 2009
Resolved 12 August 2009
Resolution: ABS Report verified completion of repairs.