Documentation record
Registered dimensions (L × B × D)334.0 ft × 70.0 ft × 25.0 ft
Registered tonnagegross 5,720 / net 5,720
ITC dimensions (L × B × D)334.0 ft × 70.0 ft × 25.0 ft
ITC tonnagegross 4,868 / net 2,672
BuilderBOLLINGER MARINE FABRICATORS LLC · AMELIA, LA, UNITED STATES · built 2009
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9658 - Dead Weight, Ton
4868 - Convention (Subpart B), Gross Ton
5720 - Regulatory (Subpart C or D), Gross Ton
2672 - Convention (Subpart B), Net Ton
5720 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 36
16 July 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8187602
5 May 2025
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8127496
16 May 2024
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7912855
8 April 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7891555
15 January 2024
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7856071
25 April 2023
MTSA/ISPS Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7675098
26 April 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7438702
5 January 2022
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7375856
5 January 2022
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7376100
17 December 2021
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7369584
26 December 2020
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7116360
2 December 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7105100
7 August 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7026688
14 February 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6908943
25 April 2019
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6669940
28 March 2019
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6651280
25 January 2018
MTSA Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex II Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6343368
5 January 2018
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6333123
28 April 2017
Internal Structural Exam · MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex II Examination · MARPOL Annex I Examination · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6132030
20 June 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5910298
21 August 2015
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5222348
1 July 2015
Deficiency Check · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5169928
8 June 2015
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5147979
2 April 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5095873
5 February 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5064818
2 April 2014
MARPOL Annex VI Survey · Drydock Exam · Internal Structural Exam · MARPOL Annex I Examination · COI Inspection · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4827518
20 June 2013
MARPOL Annex VI Survey · Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4625121
3 December 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4495199
28 June 2012
Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4359304
2 April 2012
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4276853
21 June 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4052303
29 December 2010
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3917420
30 September 2010
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3860991
25 January 2010
MTSA Verification · MARPOL Annex I Examination · MARPOL Annex II Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3669279
11 May 2009
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3472517
15 October 2008
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3439786
01 - Certificates & Documentation › 013 - Documents › Shipboard marine pollution emergency plan for NLS
Issued 16 May 2024
Resolved
Every ship of 150 gross tonnage and above certified to carry noxious liquid substances in bulk shall carry on board a shipboard marine pollution emergency plan for noxious liquid substances. Shipboard marine pollution emergency plan was not present during inspection. Shipboard marine pollution emergency plan (SMPEP) must be approved and carried onboard prior to carrying NLS cargo.
Action required: 705 - Other - as specified
Resolved 25 June 2024
Resolution: Vessel provided documentation of VRP amended w/ SMPEP revision.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 8 April 2024
Resolved
Aft Rake; measure inset along lower bilge knuckle and assess for further damage. If the area needs to be
repaired, submit a repair proposal prior to commencing
repairs.
Action required: 705 - Other - as specified
Resolved 7 May 2024
Resolution: Witnessed satisfactory repair.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 8 April 2024
Resolved
Aft Rake; repair damaged guard rails along port side of aft rake.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 7 May 2024
Resolution: Witnessed satisfactory repair.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2022
Resolved
Remove or properly store free-standing buckets and drum containing hazardous/flammable/combustible liquids.
Action required: 705 - Other - as specified
Due 24 February 2022
Resolved 24 February 2022
Resolution: Provided Objective Evidence that the drums were stored in a paint locker.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 December 2020
Resolved
BARGE EXPERIENCED IMPACT FROM A TUG THAT BROKE FREE FROM ITS MOORING. THE IMPACT WAS IN THE FORWARD RAKE ON THE STARBOARD SIDE IN THE VICINITY OF THE BILGE KNUCKLE, APPROXIMATELY 3-FEET FROM THE WATERLINE. SPACE TO BE GAS FREED AND CERTIFIED BY A MARINE CHEMIST PRIOR TO C.G. MARINE INSPECTOR ENTRY FOR A DAMAGE SURVEY.
46 CFR 35.01-1; 46 CFR 31.01-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 December 2020
Resolution: Recieved Marine Chemist certificate ceritifying space safe for entry.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 December 2020
Resolved
If during an internal structural examination damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs.
Structural damage located on the stbd bow/fwd rake must be repaired at next scheduled dry dock or as required by the OCMI, anytime the vessel is no longer fit for intended service.
Insets located on the bilge knuckle at the fwd bottom plate and side shell plate require C/R.
Logitudinal stiffener in the vicinity of damage has an approximate 04 cracked weld and will require to be V/W at next dry dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 December 2020
Resolved 5 January 2022
Resolution: Resolved in activity 7369584, repairs all completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 April 2019
Resolved
Vessel carried an inadequate number of lifebuoys.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2019
Resolved 9 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 April 2019
Resolved
Vessel carried an inadequate number of life buoys with self-igniting lights. Acquire the adequate amount and provide evidence of installation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2019
Resolved 9 May 2019
Construction/Loadline › Penetrations › Gasket
Issued 5 January 2018
Resolved
Gaskets on hatches for starboard void were either missing or non-continuous.
Action required: 705 - Other - as specified
Due 15 January 2018
Resolved 17 January 2018
Resolution: Received pictures of replaced gaskets.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 5 January 2018
Resolved
Abandon ship drills and fire fighting drills were not properly logged.
Due 5 January 2018
Resolved 5 January 2018
Resolution: Crew was trained to document as seperate drills and individual items on the log and vessel drill record.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 20 June 2016
Resolved
Vessel had no proof of annual pressure gauge testing for gargo pipping. Provide proof of annual cargo pipping gauge testing. Cite: 49CFR40
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 July 2016
Resolved 20 June 2016
Resolution: Provided document proving that gauges were tested along with pipping.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 20 June 2016
Resolved
Vessel had no proof of which personnel were enrolled in drug consortium. Provide proof of crewmember enrollment in drug testing program. Cite: 49CFR40
Due 4 July 2016
Resolved 21 June 2016
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 1 July 2015
Resolved
Barge's 240v ground detection system was inoperable at time of inspection.
Action required: 705 - Other - as specified
Due 9 July 2015
Resolved 9 July 2015
Resolution: Received tech report from vessel stating new ground detection system has been installed and tested to work.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 20 June 2013
Resolved
Investigate and provide electrician's report on faults in 240V and 120V ground detection systems. 46 CFR 111.05-21
Action required: 705 - Other - as specified
Due 19 July 2013
Resolved 8 July 2013
Resolution: Electrician replaced damaged bulbs and renewed damaged high temp wiring in forward mast floodlight. All ground detection systems tested with no faults.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 June 2013
Resolved
Properly terminate exposed wiring to battery bank between #1 and #2 generators. 46 CFR 111.60
Action required: 705 - Other - as specified
Due 19 July 2013
Resolved 8 July 2013
Resolution: Electrician properly terminated spare wiring inside battery box.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 28 June 2012
Resolved
Vessel must obtain EIAPP documents before issuance of IAPP. Prior to sailing foreign.
Action required: 705 - Other - as specified
Resolved 25 June 2013
Resolution: Vessel provided EIAPP documentation for cargo pump engines. IAPP certificate drafted for issuance.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 28 June 2012
Resolved
Vessel must correct bunker reciepts and bunker notes to correctly correspond with each other. Prior to sailing foreign.
Action required: 705 - Other - as specified
Resolved 20 June 2013
Resolution: Reviewed vessel records for bunker notes/receipts. Vessel has implemented new company procedure for tracking bunker activities and now records information on consolidated spreadsheet.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 28 June 2012
Resolved
Vessel must obtain functioning gas detection equipment. 46CFR35.30-15
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 13 July 2012
Resolution: Rcvd report, vssl has new gas meter.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 28 June 2012
Resolved
Vessel must obtain valid (not expired) line throwing appliance. [Flares should be checked at this time as well] 46CFR199.170
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 5 July 2012
Resolution: Rcvd proof or vssl rcving new LTA.
Operations/Management › Cargo Transfer/Lightering › Use of Vapor Control System
Issued 28 June 2012
Resolved
Vessel must mark vapor line in accordance with 49CFR39.20-1
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 5 July 2012
Resolution: Rcvd proof of correct marking.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 28 June 2012
Resolved
Vessel must demonstrate overspeed and low lube oil shutdowns on generators. 46CFR111.12
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 13 July 2012
Resolution: Rcvd proof of testing by generator tech.