MAURY USCG vessel records Sign in
← All vessels

ATLANTIC MAYA

ATLANTIC MAYA is a 2005 freight ship. The Coast Guard has recorded 21 inspections since 2008, most recently in August 2022, along with 5 deficiencies and 4 operational controls.

Records from 2008 to 2022. Most recent: inspection, 21 August 2022.

Built
2005
Last inspected
21 August 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9303003 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V3071
939189
Flag
SINGAPORE
—
Maury page id
psix-939189

Inspections, by type

…with no type recorded6
Years with a record 7 calendar years (2008–2022)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it56052 - Dead Weight, Metric Ton
64557 - Displacement, Metric Ton
31232 - Convention (Subpart B), Gross Ton
18504 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ART 35227B Freight Barge · MISLE 1065165 · 29 August 2021 · activity 7313883

Inspection history · 21

21 August 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7539597
19 August 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7538311
14 March 2022 PSC B
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7407136
2 October 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7326201
30 September 2021 Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7324859
4 September 2021 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7303855
29 August 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7313883
23 July 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7257132
23 June 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7234240
21 June 2021 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7231772
27 March 2020 PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6929890
26 March 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6931967
3 November 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6294708
22 March 2017 COE-Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6103595
21 October 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6027050
15 July 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5944872
23 December 2015 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5784361
21 July 2015 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5190560
1 March 2008 MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3152248
29 February 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3152237
26 February 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3154317

Deficiency record · 5

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Due to heavy weather, the vessel was pushed aground in Lower Mississippi river. Certification issuing authority to attest to the proper operation of steering gear, propulsion machinery and associated equipment, and integrity of the hull in affected area, and anchor loss. Code: 02106 74 SOLAS (20) I/II (a) 60 (a)(c)
Action required: 60 - Rectify deficiencies prior to movement
Due 4 September 2021
Resolved 4 September 2021
Resolution: Received, reviewed, and accepted class report from [name withheld] stating that the deficiency was rectified.
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 21 October 2016 Resolved
<0999> 74SOLAS(2014 CONS. ED.)I/11(a) (40AC) The condition of the ship and its equipment shall be maintained to conform w/ the provisions of the present regulations to ensure that the ship in all repsects will remain fit to procedd to sea w/o danger. Boiler piping leading to laundry does not meet ships standard. PVS piping installed is damaged due to heat and poses risk of bursting and flooding.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 November 2016
Resolution: PVC pipe damaged length now cropped and renewed w/ approved PVC pipes and connectors as per ship's approved drawings. PVC pipe length now installed, tested under working conditions and found free of leaks or deformations.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 21 July 2015 Resolved
0750: The fire integrity of fire boundary divisions shall be maintained at openings and penetrations. The door to the galley, door to the stair tower on 'A' Deck, ships laundry door, drying room door and door to engine room are not self closing as required to maintain the boundary and as per the fire control plan. 74SOLAS(04) II-2/9.1.3...10c
Action required: 705 - Other - as specified
Resolved 21 July 2015
Resolution: Before departing the ship all self closing doors had been fixed to comply with the regulations and ships fire control plan. All doors were checked and found satisfactory to PSCO.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 21 July 2015 Resolved
1330: The machinery and associated piping systems and fitting shall be adequate for the service for which they are intended and shall be so installed as to reduce to a minimum any danger to persons on board. There is a hydraulic leak and excessive hydraulic oil in the surrounding area of the controls for the mooring winch and windlass. 74SOLAS(04) II-1/26...40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 December 2015
Resolution: PSC NOLA received a class report from Lloyd's Register satisfying the requirement.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 21 July 2015 Resolved
0330:The condition of the ship and its equipment shall be maintained and no changes shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the administration. Ship’s crew is using the aft peak tank as a sewage holding tank.74SOLAS(14)I/II 40ac....Continued in narrative of Activity # 5190560
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 December 2015
Resolution: PSC NOLA received a class report from Lloyd's Register satisfying the requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.