MAURY USCG vessel records Sign in
← All vessels

LILA KINGSTON

LILA KINGSTON is a 2007 tank ship. The Coast Guard has recorded 20 inspections since 2008, most recently in July 2025, along with 7 deficiencies and 3 operational controls.

Records from 2008 to 2025. Most recent: inspection, 18 July 2025.

Built
2007
Last inspected
18 July 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9380362 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
939437
Flag
LIBERIA
—
Maury page id
psix-939437

Inspections, by type

…with no type recorded4
Years with a record 11 calendar years (2008–2025)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it49999 - Dead Weight, Metric Ton
59339 - Displacement, Metric Ton
29324 - Convention (Subpart B), Gross Ton
13205 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

18 July 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8188862
9 July 2025 COC-CHEM & TVE Renew · Deficiency Check · Administrative Inspection · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8174809
8 July 2024 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7952590
24 May 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7690820
4 October 2021 PSC B · COC-CHEM Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7324720
2 December 2020 PSC B · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7104147
9 January 2020 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6886502
4 October 2019 Ballast Water Examination · COC-CHEM & TVE Renew · Deficiency Check · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6822846
12 March 2019 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6639264
3 December 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6591397
18 September 2018 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6541463
4 October 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6280721
23 July 2015 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5193493
26 August 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4127932
16 August 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4116978
9 February 2011 Type not recorded
No type recorded · Station Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3942352
8 February 2011 COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3941314
6 October 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3339509
19 August 2008 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3304614
10 March 2008 Ballast Water Examination · COC-CVE Initial · ISPS II Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3160642

Deficiency record · 7

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 July 2025 Resolved
Every ship to which this annex applies shall be provided with a cargo record, in the form specified in the appendix II to this annex. The ship does not have a cargo record book on board. MARPOL II/15.1
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2025
Resolved 9 July 2025
Resolution: Cargo record book provided to the ship by the agent and filled out by the master.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 July 2025 Resolved
Muster and embarkation stations shall be adequalety illuminated by lighting. PSCO identified that the lighting at the embarkation stations were not capable of being illuminated. SOLAS 20 III/11.4
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2025
Resolved 10 July 2025
Resolution: muster and embarkation station lighting repaired. ABS issued report stating lights were repaired. Photo evidence submitted by ship showing working lights.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 July 2025 Resolved
Elictrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. Three junction boxes found at the embarkation station are improerly sealed. SOLAS 04 II-1/40.1.3
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2025
Resolved 10 July 2025
Resolution: ABS submitted report stating 03 junction boxes sealed properly. Photo evidence submitted by ship proving junction boxes are sealed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 July 2025 Resolved
The cargo record book shall be kept in such a place as to be readily available for inspection and it shall be retained for a period of three years after the last entry has been made. The ship has not retained cargo record books for the last three years. MARPOL 11/15.5
Action required: 10 - Deficiency Rectified
Due 9 July 2025
Resolved 9 July 2025
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 October 2019 Resolved
A chemical tanker shall comply with the requirements of the International Bulk Chemical Code. The stowage space shall be cell-divided in order to avoid shifting of the bottles at sea. Samples which react with each other dangerously shall not be stowed closed to each other. Cargo samples are stowed atop one another and are not stowed within cell divided locations. PSCO noted caps for several cargo sample bottles were not tightened, allowing cargo to spill from jars and have rendered labels unreadable, preventing PSCO from verifying cargo sample storage compatibility. 74SOLAS(14) VII/10.1 Ref IBC 16.5.2.1 & 16.5.3 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2019
Resolved 5 October 2019
Resolution: Vessel provided proof that they disposed all Cargo Sample bottles with loose caps which rendered the labels unreadable to be disposed of at a shore facility.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 10 February 2011 Resolved
Oxygen analyzer for IGS does not calibrate. Repair prior to conducting cargo discharge operations requiring IGS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 February 2011
Resolution: Crew changed air filters on analyzer and system calibrated properly.
Deck/Cargo › Cargo Stowage › General
Issued 8 February 2011 Resolved
Chemical sample locker was overstocked and sample bottles were stacked on top of each other and lying on their side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2011
Resolved 10 February 2011
Resolution: Sample locker organized. Temporary locker constructed to hold excess samples.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.