MAURY USCG vessel records Sign in
← All vessels

CELEBRITY EQUINOX

CELEBRITY EQUINOX is a 2009 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2010, most recently in December 2024, along with 12 deficiencies and 1 operational control.

Records from 2010 to 2024. Most recent: inspection, 3 December 2024.

Built
2009
Last inspected
3 December 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9372456 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
939440
Flag
MALTA
—
Maury page id
psix-939440

Inspections, by type

…with no type recorded5
Years with a record 12 calendar years (2010–2024)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it121878 - Regulatory (Subpart C or D), Gross Ton
121878 - Convention (Subpart B), Gross Ton
82363 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

3 December 2024 COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8041820
9 January 2024 COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7845889
8 July 2023 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7734711
27 February 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7642768
12 January 2023 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7620068
16 July 2022 PSC A · Administrative Inspection · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7508153
13 March 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7411184
21 January 2022 Periodic Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7382831
10 August 2021 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7282369
20 July 2021 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7255755
6 November 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7090811
3 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935057
23 September 2019 ISPS III Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6818019
30 March 2019 ISPS III Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6652032
5 October 2018 ISPS III Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6555417
9 June 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6439357
25 April 2018 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6403022
23 April 2018 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6397529
31 March 2018 COC-CVE Quarterly · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6380540
3 January 2018 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6331818
23 December 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6335681
5 October 2017 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6282048
20 July 2017 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6215214
15 May 2017 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6143878
4 November 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6035344
4 November 2016 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6035415
5 November 2015 ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5757857
26 December 2011 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4213982
23 December 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4214637
12 December 2011 ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4204508
25 November 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3900205
15 November 2010 COC-CVE Annual · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3887044

Deficiency record · 12

Lifesaving › Lifeboat › Hull
Issued 23 April 2018 Resolved
All lifeboats shall have rigid hulls and shall be capable of maintaining positice stability when in upright position in calm water and loaded with their full complement of persons. PSCO notified of facility skyway extending over pier which allided with #22 lifeboat causing two hull punctures. 74 SOLAS (14) III/34 LSA code 4.4.1.1
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 25 April 2018
Resolution: Examined lifeboat repairs conducted by Messers BC Service, repairs satisfactory.
Personnel › Training › Lifeboatman
Issued 9 November 2015 Resolved
0299 - Every crewmember with assigned emergency duties shall be familiar with these duties before the voyage begins. Lifeboat commanders and Second commanders were not familiar with emergency procedures. Additionally, MES sweepers were unfamiliar with duties. 74SOLAS(14 cons.) CH.III/Reg.19.2.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 November 2015
Resolution: Vessel conducted additional training and a second lifeboat drill was conducted.
Fire Fighting › Means of Escape › Blocked
Issued 9 November 2015 Resolved
0960 - Escape routes shall be maintained in a safe condition, clear of obstacles. the secondary means of escape in the hotel replaceable store within the linen store is blocked. 74SOLAS(14 cons.) CH.II-2/Reg.13.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 November 2015
Resolution: The Escape route was cleared of debris/boxes.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 12 December 2011 Resolved
74SOLAS09CHII-2/Reg 9.2.2.3.2.2 Where the contents and use of a space are such that there is doubt as to its classification, it shall be treated as a space within the relevant category having the most stringent requirements. Found portable flamable liquid locker in spa on deck 12, and in store room 01-1-006 containing more than daily use; and also found additional flamable liquids outside of lock
Action required: 705 - Other - as specified
Due 19 December 2011
Resolved 26 December 2011
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 12 December 2011 Resolved
74SOLAS09 CHII-2/REG 9.2.2.3.2.2 Where the contents and use of a space are such that there is doubt as to its classification it shall be treated as a space within the relevant category having most stringent requirements. Two crew lockers (12-5-001 & 10-2-3) have been converted into offices containing flamable materials.
Due 12 December 2011
Resolved 12 December 2011
Resolution: Corrected on the spot
Fire Fighting › Means of Escape › Enclosed Stairway
Issued 12 December 2011 Resolved
74SOLAS09 CHII-2/Reg 13.3.1.1 Stairways shall be so arranged as to provide ready means of escape to the lifeboat and liferaft embarkation deck from passenger/crew accomodation spaces. FSD leading to crew corridor on deck 8 fwd was blocked with luggage; playroom emergency exit blocked by video game; corridor outside payroll office was also blocked.
Due 12 December 2011
Resolved 12 December 2011
Resolution: Corrected on the spot
Fire Fighting › Means of Escape › Stairways
Issued 12 December 2011 Resolved
74SOLAS09 CHII-2/Reg9.4.1.2.1 Doors in B class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to the division. B-15 door from copy room on deck 2 found unable to close due to copy machine in way of the door.
Due 12 December 2011
Resolved 12 December 2011
Resolution: Corrected on the spot
Fire Fighting › Means of Escape › Stairways
Issued 12 December 2011 Resolved
74SOLAS09 CHII-2/Reg5.3.3 Furniture in stairway enclosures shall be limited to seating which shall be fixed and not restrict passenger escape routes. Multiple ornaments and diplay tables in passenger stairways; ornaments easily moved and found blocking a fire screen door on deck 5.
Due 12 December 2011
Resolved 12 December 2011
Resolution: Corrected on the spot
Fire Fighting › Combustible Materials › Grounds
Issued 15 November 2010 Resolved
0710 Fire prevention: Where the contents and use of a space are such that there is a doubt as to its classification to a space, it shall be treated as a space within the relevant category. AC room 2.06 had flammable material stored in it. SOLAS 2009 CH II-2, REG 9.2.2.3.2.2.
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 15 November 2010
Resolution: Deficiency rectified prior to completion of exam to the satisfaction of the Coast Guard.
Fire Fighting › Means of Escape › Blocked
Issued 15 November 2010 Resolved
0960 Means of escape: Escape routes shall be maintained in a safe condition, clear of obstacles. Emergency escape was blocked in carpet stores FP.02-1-002 crew stairwells on deck 5, deck 2 outside medical. SOLAS 2009 CH II-2 REG 13.2
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 15 November 2010
Resolution: Deficiency rectified prior to completion of exam, to the satisfaction of Coast Guard examiners.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 15 November 2010 Resolved
0750 Fire prevention: Hold back hooks not subject to central control stations release are prohibited. Cabin doors in "B" class divisions shall be of self closing type. Hold back hooks are not permitted. Multiple doors found with hold backs. SOLAS 2009 CH II-2 REG 9.4.1.1.4.4 And REG 9.4.1.2.2
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 24 November 2010
Resolution: Received report from vessel stating that they have addressed the issue by holding training for housekeeping personnel.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 15 November 2010 Resolved
0750 Fire prevention: Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. All waste receptacles in garbage room found to be plastic construction. SOLAS 2009 CH II-2, REG 4.2.
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 24 November 2010
Resolution: Received report from vessel showing the order submitted for procuring new metal waste receptacles.

Ownership record