← All vessels
OLYMPIC FLAME
OLYMPIC FLAME is a 2007 tank ship. The Coast Guard has recorded 28 inspections since 2008, most recently in November 2025, along with 22 deficiencies — 3 with no resolution recorded — and 7 operational controls.
Records from 2008 to 2025. Most recent: inspection, 11 November 2025.
- Built
- 2007
- Last inspected
- 11 November 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 22 recorded · 3 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9298375 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
8PAN5
939992
Flag
LIBERIA
—
Maury page id
psix-939992
Inspections, by type
…with no type recorded6
…past their stated due date3
Years with a record
14 calendar years (2008–2025)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it27497 - Displacement, Metric Ton
20636 - Dead Weight, Metric Ton
12776 - Convention (Subpart B), Gross Ton
6673 - Convention (Subpart B), Net Ton
20636 - Dead Weight, Metric Ton
12776 - Convention (Subpart B), Gross Ton
6673 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 28
11 November 2025
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8261057
10 November 2025
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8266514
5 November 2025
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8260965
30 October 2025
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8261030
8 November 2023
In-Service Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7820105
11 September 2023
Administrative Inspection
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7789491
2 June 2022
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7466078
10 May 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7447372
19 June 2021
COC-CHEM Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7223661
22 April 2021
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7180682
23 June 2020
COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6979229
12 June 2019
COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6710871
20 December 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6601083
10 June 2018
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6431393
29 November 2015
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5771078
24 November 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5769819
12 November 2015
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5762223
4 May 2014
Enhanced Seaway Inspection (Massena only) · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4850752
19 July 2012
ISPS III Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4380867
6 December 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4202896
26 July 2011
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 4084126
22 February 2010
Random ISPS/MTSA/PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3684150
6 December 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3644562
11 July 2009
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3530807
8 June 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3230624
23 March 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3169971
18 March 2008
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3163809
12 March 2008
COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3162832
Deficiency record · 22
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 11 November 2025
No resolution recorded
For tankers of 20,000 tonnes deadweight and upwards, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the Fire Safety Systems Code, except that, in lieu of the above, the Administration, after having given consideration to the ship's arrangement and equipment, may accept other fixed installations if they afford protection equivalent to the above. During the exam, nitrogen inert gas system was unable to be verified due to the inability to demonstrate calibration. No cargo requiring inerting is to be carried in the United States. - 74 SOLAS (2004) II-2/4.5.5.1.1
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 November 2025
No resolution recorded
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the administration. The PSCO identified multiple wires leading to the ship's lighting that are installed in the hazardous area that have improper splices. - 74 SOLAS (2004) II-1/45.5.4
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 November 2025
No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel lost their port side anchor. - 74 SOLAS (2020) I/11
Deck/Cargo › Inert Gas System › Venting System
Issued 12 November 2015
Resolved
Any other machinery space shall be adequately ventilated appropriate for the purpose of that machinery space. While conducting and operational test of the nitrogen gas generator, PSCE observed oxygen level increase from 20.9% to 27%. After further investigation the PSCE identified the oxygen exhaust approximately 6 feet awat from the spaces ventilation causing and increased oxygen levels.
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 December 2011
Resolved
The X-band radar was reported as not operational.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 22 February 2010
Resolved
The Emergency Fire Pumps is inoperable due to the power cord being damaged from heavy weather. Solas 2004 Con. Ch. II-2 Reg 10.2.2.3.1.2 - To the satisfaction of attending Class Society.
Construction/Loadline › Structures › Door
Issued 22 February 2010
Resolved
Door leading to forward bosun's store was severly warped from heavy weather and does not create a watertight seal allowing for water ingress. To the satisfaction of attending Class Society. ICLL 1966 Annex I Ch. II Reg 12.1
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 22 February 2010
Resolved
Vessel's voyage data recorder is not operable, vessel is required to have an operable voyage data recorder. To the satisfaction of attending Class Society. Solas 2004 Con. Ch V Reg. 18.2
Lifesaving › Lifeboat Equipment › Food Ration
Issued 12 March 2008
Resolved
Vessel's lifeboat (stern launch) had only 20 packages of food rations, 22 are required (22 person capacity). Vessel to provide proof of purchase of two food rations to meet required amount of rations to the satisfaction of class. SOLAS 74 III/31.1 - LSA Code 4.4.8
Personnel › Training › Safety Orientation
Issued 12 March 2008
Resolved
Vessel's crew members unable to demonstrate proper operation/activation of fixed CO2 flooding fire fighting system for machinery spaces. Prove proper crew training/knowledge for operation of critical vessel system to satisfaction of class.
SOLAS 74 XI-1/4
Construction/Loadline › Structures › Door
Issued 12 March 2008
Resolved
Provide proper operation of door "PD-21" from poop deck into accommodation. Door is required to provide weather tight seal, however daylight is clearly visible while door is fully closed. Class to attest to the weather tight integrity of door "PD-21".
ILLC 66 Reg 12
Construction/Loadline › Structures › End Bulkhead
Issued 12 March 2008
Resolved
Prove closure to weather tight standard or better for hole drilled through bulkhead (2 1/2") at deck level, aft on accommodation deck between weather and accommodation space, to the satisfaction of class. ILLC 66 Reg 18 - SOLAS 74 I/11
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 12 March 2008
Resolved
Prove proper operation of emergency fire pump to the satisfaction of class. Found leaking more than 2 liters per minute at joint between motor and pump housing, at port side pump. SOLAS 74 II-2/14.2.1
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 March 2008
Resolved
Found 7 (seven) fire doors that fail to fully close and latch as required for structural fire protection. (1) 1st Accom stair tower "101" (2) 3rd Accom stair tower "301" (3) Entrance to engine space from poop level accom main passageway (4) Emergency gen space entrance "MD-16" (5) Steering gear room access "MD-15" (6) Entrance to IGG room "MD-16" (7) Upper engine room escape. SOLAS 74 II-2/4.1.1.4
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 12 March 2008
Resolved
Vsls safe manning doc states unlicensed mariner reqmnts for nav may be met by 1 bosn (STCW II/4) and 3 deck ratings (STCW VI/1) The crew filling deck rating are holding II/4 & are on vsls watch rotation for nav duties and therefore require training to II/4 level Flag to review SM doc & attest to correct manning for safe nav. SOLAS 74 V/14 & IMO res A.890(21)
Engineering › Thrusters › Motor
Issued 12 March 2008
Resolved
Renew motor ground connection in bow thruster space (STBD side). Class to attest to proper repair. SOLAS 74 II-1/45.1.1
Lifesaving › Inflatable Liferafts › Container Marking
Issued 12 March 2008
Resolved
Install life raft identification/inspection card into ID tube of port side life raft as required. Class to attest to ID card being placed in tube. SOLAS 74 III/31.1 - LSA Code 4.2.7.2
Lifesaving › Inflatable Liferafts › Markings
Issued 12 March 2008
Resolved
Provide marking on 6 person life raft as required on container, with respect to type of SOLAS pack. Class to attest to markings. SOLAS 74 III/31.1 - LSA Code 4.2.7
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 12 March 2008
Resolved
Prove installation of studs to prevent cargo hose connection onto forward vapor line, including all flanges/spool pieces/reducers as required and attested to in class certificate of compliance (with U.S. vapor control requirements as per 46 CFR) dated 15NOV2007. Class to attest to installation of studs.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 12 March 2008
Resolved
No span gas is available on board for calibration for vessel's req. portable gas detectors. Provide proof of all req. span gas detectors in accordance with manf's req. to ensure proper op/reliability of meters. Class to attest prior to loading any cargo on vessel, where portable gas detection is required in IBC code (13.2, Column K) or prior to loading oil cargo. SOLAS 74 VII/10 & SOLAS 74 II-2/5
Construction/Loadline › Hull › Double Hull
Issued 12 March 2008
Resolved
Double Hull/ Double Bottom Space gas detection system (fixed) indicates several sample locations as disconnected. System to be restored to proper working condition prior to loading cargos which require gas detection. Class to attest.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 12 March 2008
Resolved
High level and overfill alarms for port side slop tank is inoperative (tank 9 port / portside slop tank). Prove proper operation of tank level alarms prior to loading any cargo into this tank for which high level alarm or overfill protection is required to the satisfaction of class prior to loading cargo. SOLAS 74 I/11
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.