Records from 2007 to 2024. Most recent: inspection, 30 January 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
30 January 2024
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7857824
15 December 2020
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7111878
15 April 2019
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6663112
22 May 2017
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6155597
6 September 2016
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5986238
1 October 2015
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5733731
19 August 2015
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5220627
19 July 2015
In-Service Inspection
Physical examination · Commandant (CG-5P-TI) · Activity 5791951
23 October 2014
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5010063
28 August 2014
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4966799
28 August 2014
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4968669
21 February 2012
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4243307
1 March 2010
Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3688010
18 June 2007
Initial Certification · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3267649
Construction/Loadline › Hull › Stiffener
Issued 22 May 2017
Resolved
Crop out and renew starboard side frame #5 (rotted). USCG CG-835 issued on July 10th, 2015 required item to be repaired at next scheduled dry-dock. Repairs should be made after consultation from a qualified shipwright familiar with cross-plank deadrise construction and approval of the local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2020
Resolution: As directed by the CID this deficiency is cleared for MISLE cleanup, vessel is out of service and a special note has been added for this activity to ensure this deficiency is reviewed prior to issuing COI.
Construction/Loadline › Hull › Stiffener
Issued 22 May 2017
Resolved
Crop out and renew port side frame #6 (rotted frame head). USCG CG-835 issued on July 10th, 2015 required item to be repaired at next scheduled dry-dock. Repairs should be made after consultation from a qualified shipwright familiar with cross-plank deadrise construction and approval of the local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2020
Resolution: As directed by the CID this deficiency is cleared for MISLE cleanup, vessel is out of service and a special note has been added for this activity to ensure this deficiency is reviewed prior to issuing COI.
Construction/Loadline › Hull › Hull Plating
Issued 22 May 2017
Resolved
Identified inter plank decay on the interior side of bottom plank #6 (counted from the transom on the port side) between bottom plank #6 & #7. Repairs should be made after consultation from a qualified shipwright familiar with cross-plank deadrise construction and approval of the local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2020
Resolution: As directed by the CID this deficiency is cleared for MISLE cleanup, vessel is out of service and a special note has been added for this activity to ensure this deficiency is reviewed prior to issuing COI.
Construction/Loadline › Hull › Hull Plating
Issued 22 May 2017
Resolved
Identified areas of rot on the port chine log between side frames #16 and #18. Make permanent repairs to the satisfaction of the attending marine inspector. Repairs should be made after consultation from a qualified shipwright familiar with cross-plank deadrise construction and approval of the local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2020
Construction/Loadline › Hull › Hull Plating
Issued 22 May 2017
Resolved
Renew caulking where indicated on exterior hull.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2020
Resolution: As directed by the CID this deficiency is cleared for MISLE cleanup, vessel is out of service and a special note has been added for this activity to ensure this deficiency is reviewed prior to issuing COI.
Construction/Loadline › Hull › Stiffener
Issued 22 May 2017
Resolved
Identified port side frame #17 (rotted). Repairs should be made after consultation from a qualified shipwright familiar with cross-plank deadrise construction and approval of the local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2020
Resolution: As directed by the CID this deficiency is cleared for MISLE cleanup, vessel is out of service and a special note has been added for this activity to ensure this deficiency is reviewed prior to issuing COI.
Construction/Loadline › Structures › Superstructure
Issued 22 May 2017
Resolved
Identified aft port cabin top (rot) where indicated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2020
Resolution: As directed by the CID this deficiency is cleared for MISLE cleanup, vessel is out of service and a special note has been added for this activity to ensure this deficiency is reviewed prior to issuing COI.
Fire Fighting › Fire Bucket › Availability
Issued 6 September 2016
Resolved
Provide three 2.5 Fire buckets with marking and landyards.
Action required: 705 - Other - as specified
Due 6 October 2016
Resolved 25 October 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 September 2016
Resolved
Prove proper operation of all NAV lights. No night ops until corrected.
Action required: 705 - Other - as specified
Due 6 October 2016
Resolved 25 October 2016
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 6 September 2016
Resolved
Provide current tide tables.
Action required: 705 - Other - as specified
Due 6 October 2016
Resolved 25 October 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 August 2015
Resolved
Re-new battery IWO life ring portable light
Action required: 705 - Other - as specified
Due 20 September 2015
Resolved 6 September 2016
Resolution: Battery installed light operating properly
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 August 2015
Resolved
Provide updated navigation publications for area of operation (Light List, Tide/Current Tables)
Action required: 705 - Other - as specified
Due 20 September 2015
Resolved 6 September 2016
Resolution: Vsl CAPT printed updated light list information and added to light list book.
Construction/Loadline › Hull › Bottom Plating
Issued 23 October 2014
Resolved
Attending inspectors noted active seepage IWO port chine log @ FR #: 17-18. This area has been noted by attending inspectors and has been added to the list of areas to monitor.
Action required: 705 - Other - as specified
Resolved 22 April 2015
Resolution: Attending inspectors addressed the area of the port chine log during most recent drydock. The starter plank IWO chine log between port frames #13-18 were re-caulked. Attending inspectors will continue to monitor at subsequent inspections.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 28 August 2014
Resolved
Fuel fill hose from deck to fuel tank is not double clamped on both ends. add second hose clamp on both ends to properly secure the fill hose.
Condition: Improper Installation
Due 27 September 2014
Resolved 23 October 2014
Resolution: Attending inspectors verified intallation of hose clamps IWO fuel hoses/connections.
Engineering › Fuel Oil Service System › Hose
Issued 28 August 2014
Resolved
Provide SAE J-1942 or USCG A1, A2, B1, or B2 standard fuel service line on Diesel engine.
Condition: Placed in Improper Service
Due 27 September 2014
Resolved 23 October 2014
Resolution: Attending inspectors verified installation of new fuel hose.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 August 2014
Resolved
Replace batteries in waterlight annually.
Condition: Improper/Lack of Maintenance
Due 27 September 2014
Resolved 23 October 2014
Resolution: Attending inspectors verified battery replacement IWO floating waterlight.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 August 2014
Resolved
Provide FCC Radio station license
Condition: Invalid
Due 27 September 2014
Resolved 11 February 2015
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Communications › Radio Communications › VHF Radiotelephone
Issued 28 August 2014
Resolved
Provide FCC radio station Telephony certificate for vessel
Condition: Invalid
Due 27 September 2014
Resolved 22 April 2015
Resolution: Attending inspectors verified presence of FCC Radio Safety Telephony Certificate.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 August 2014
Resolved
Provide restricted radio operators permit
Due 27 September 2014
Resolved 23 October 2014
Resolution: Attending inspectors verified the carriage of FCC Restricted Radio Operators Permit (vessels crew).
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 August 2014
Resolved
Provide current navigation pubs, light list,tide and current tables, coast pilot, for operating ares
Condition: Improper/Lack of Maintenance
Due 27 September 2014
Resolved 23 October 2014
Resolution: Attending inspectors verified vessel carried current/up to date navigation publications for areas transited.
Sail Rigging › Deck Hardware › Travellers and Blocks
Issued 28 August 2014
Resolved
Replace / repair jib block cheek, which is fractured.
Condition: Damaged By Earlier Event
Due 27 September 2014
Resolved 23 October 2014
Resolution: Attending inspector verified replacement of jib block cheek.
Sail Rigging › Running Rigging › Halyards
Issued 28 August 2014
Resolved
Renew / replace jib halyard.
Condition: Improper/Lack of Maintenance
Due 27 September 2014
Resolved 23 October 2014
Resolution: Attending inspectors witnessed repairs made IWO jib halyard.
Construction/Loadline › Structures › Scupper
Issued 28 August 2014
Resolved
Repair strongback / combing IWO port stern where rotted.
Condition: Improper/Lack of Maintenance
Due 27 September 2014
Resolved 23 October 2014
Resolution: Attending inspectors witnessed repairs made IWO strongback.
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 28 August 2014
Resolved
Attending inspectors noted that vessel was carrying approximately 50 gallons of diesel on board in non-approved fuel containers. Fuel containers did not meet the requirements of 46 CFR 182.440(a)(2) and are required to be removed from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2014
Resolved 23 October 2014
Resolution: Attending inspectors verified removal of un-approved portable fuel containers that were stowed beneath the main deck.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 June 2008
Resolved
Properly label lifejacket storage boxes with correct number of adult and child lifejackets.
Action required: 705 - Other - as specified
Due 27 July 2008
Resolved 15 April 2010
Documentation › Certificates/Documents › FCC SSL
Issued 27 June 2008
Resolved
Owner has applied for but not received FCC license. Provide proof of license upon receipt.
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 15 April 2010