MAURY USCG vessel records Sign in
← All vessels

ARVIN

ARVIN is a 2008 tank ship. The Coast Guard has recorded 24 inspections since 2008, most recently in October 2025, along with 5 deficiencies and 6 operational controls.

Records from 2008 to 2025. Most recent: inspection, 29 October 2025.

Built
2008
Last inspected
29 October 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9374272 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
940355
Flag
LIBERIA
—
Maury page id
psix-940355

Inspections, by type

…with no type recorded9
Years with a record 9 calendar years (2008–2025)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29307 - Convention (Subpart B), Gross Ton
47134 - Dead Weight, Metric Ton
56280 - Displacement, Metric Ton
12026 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

29 October 2025 Administrative Inspection
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8260400
9 September 2025 COC-CHEM & TVE Renew
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8227797
12 November 2024 Administrative Inspection · Deficiency Check · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8031516
16 April 2024 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7896070
15 April 2024 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7895236
14 April 2024 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7914885
20 February 2024 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7867715
18 August 2023 COC-CHEM & TVE Renew · COC-CHEM Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7760596
13 May 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7448834
13 August 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7031793
19 July 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7010038
20 May 2020 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6956564
19 May 2020 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6955936
20 June 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6720381
22 May 2019 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6703355
9 May 2019 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6678804
8 May 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6679867
8 May 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6679876
29 April 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6672370
14 October 2017 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6285030
14 October 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6287428
15 April 2016 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5852881
1 May 2008 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3196765
16 March 2008 ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3160482

Deficiency record · 5

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 November 2024 Resolved
06199-Cargo Operations- Vapor Line Flange not in compliance with CFR.Observed STBD Forwad vapor flange missing stud. 46CFR39 2001(j)
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 November 2024
14 - Pollution Prevention › 146 - MARPOL Annex VI › Sulphur oxides
Issued 16 April 2024 Resolved
WHILE SHIPS ARE OPERATING WITHIN AN EMISSION CONTROL AREA, THE SULPHUR CONTENT OF FUEL OIL USED ON BOARD SHIPS SHALL NOT EXCEED 0.10% M/M ON AND AFTER 1 JANUARY 2015. WHILE VESSEL WAS WITHIN THE UNITED STATES CARIBBEAN SEA AREA, THE FUEL OIL USED TO ENTER PORT WAS 0.477% SULPHUR CONTENT DUE TO THE MAIN ENGINE BEING UNABLE TO RUN ON THE 0.082% SULPHUR CONTENT FUEL OIL ON BOARD. MARPOL ANNEX VI/14.4.3
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2024
Resolved 17 April 2024
Resolution: Accepted ABS class report. Vessel able to burn ULSD in ECA.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 19 May 2020 Resolved
Each liferaft shall be stowed with a float free arrangement. The port side liferaft painter was not connected to the weak link. 74SOLAS(14)III/13.4.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 May 2020
Resolved 28 May 2020
Resolution: Port side life raft installation was corrected.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 16 March 2008 Resolved
High level cargo alarm is not operational. The audible function for this alarm cannot be heard on deck. Vessel cannot load in a U.S. port until def is rectified. Rectify def prior to next U.S. port after sailing foreign. 46 CFR 39.20-7(c)(3)
Action required: 705 - Other - as specified
Resolved 1 May 2008
Resolution: New power indicating lamps and IS barriers were installed and visual/audible test was conducted by the vessel''s Classification Society.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 16 March 2008 Resolved
Non-Conductive matting is missing throughout the entire vessel to prevent electrical shock hazard's on all high voltage panels. Rectify def prior to next U.S. port after sailing foreign. SOLAS 2004 cons. Ch II-I Reg. 45.1.3
Action required: 705 - Other - as specified
Resolved 1 May 2008
Resolution: Missing non-conductive matting throughout the entire vessel were installed and confirmed by attending Class Surveyor.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.