← All vessels
GLADIATOR
Freight Ship · Bulk Carrier class · Built 2000s · USCG East District (CGD-E) · Other hulls named GLADIATOR
GLADIATOR is a 2008 freight ship. The Coast Guard has recorded 9 inspections since 2008, most recently in October 2025, along with 11 deficiencies — 1 with no resolution recorded — and 3 operational controls.
Records from 2008 to 2025. Most recent: operational control imposed, 23 October 2025.
- Built
- 2008
- Last inspected
- 23 October 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 11 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9445033 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7NR2
940407
Flag
MARSHALL ISLANDS
—
Maury page id
psix-940407
Inspections, by type
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it28341 - Dead Weight, Ton
34753 - Displacement, Ton
17018 - Convention (Subpart B), Gross Ton
17018 - Simplified, Gross Ton
10104 - Convention (Subpart B), Net Ton
10104 - Simplified, Net Ton
34753 - Displacement, Ton
17018 - Convention (Subpart B), Gross Ton
17018 - Simplified, Gross Ton
10104 - Convention (Subpart B), Net Ton
10104 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 9
23 October 2025
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8249006
9 October 2025
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8251727
21 October 2020
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7081044
6 March 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6360383
9 February 2018
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6352784
8 October 2014
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5001349
25 November 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3895868
2 November 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3877086
21 March 2008
PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3161559
Deficiency record · 11
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 October 2025
Resolved
THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE ISM CODE. THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS. THE COMPANY SHOULD ENSURE; APPROPRIATE CORRECTIVE ACTION IS TAKEN. PSCO OBSERVED, DURING AN EXPANDED EXAM, THE FOLLOWING: FAILURE OF THE COMPANY AND SHIP TO PROPERLY MANAGE FAILING CO2 PIPING AND SUPPORT BRACKETS. AN EXTERNAL ISM AUDIT IS REQUIRED PRIOR TO RELEASE FROM THE DETENTION.
74SOLAS(24)IX/3.1
ISM CODE 10
30abc
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 October 2025
Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED HOLE IN CO2 LINE ON THE PORT SIDE FORWARD CORNER ALONGSIDE CARGO HOLD #5 AND SEVERAL BROKEN CO2 LINE BRACKETS RENDERING THE SYSTEM INOPERABLE FOR CARGO HOLD #4.
74SOLAS(24)II-2/14.2.1.2
30abc
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 23 October 2025
No resolution recorded
BULK CARRIERS SHALL COMPLY WITH THE MAINTENANCE REQUIREMENTS PROVIDED IN REGULATION II-1/3-1 AND THE STANDARDS FOR OWNERS' INSPECTION AND MAINTENANCE OF BULK CARRIER HATCH COVERS, ADOPTED BY THE ORGANIZATION BY RESOLUTION MSC.169(79), AS MAY BE AMENDED BY THE ORGANIZATION, PROVIDED THAT SUCH AMENDMENTS ARE ADOPTED, BROUGHT INTO FORCE AND TAKE EFFECT IN ACCORDANCE WITH THE PROVISIONS OF ARTICLE VIII OF THE PRESENT CONVENTION CONCERNING THE AMENDMENT PROCEDURES APPLICABLE TO THE ANNEX OTHER THAN CHAPTER I. PSCO OBSERVED EXCESSIVE WASTAGE OF SEVERAL CLEATS THOUGHOUT CARGO HOLD HATCHES, HYDRAULIC VALVE LEAK ON CARGO HATCH #5 OPENING AND CLOSING SYSTEM, AND HYDRAULIC RAM LEAK ON CARGO HOLD #1 PORT SIDE.
74SOLAS(24)XII/7.2
40ac
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 23 October 2025
Resolved
THE PURPOSE OF THIS REGULATION IS TO PROVIDE MEANS OF ESCAPE SO THAT PERSONS ON BOARD CAN SAFELY AND SWIFTLY ESCAPE TO THE LIFEBOAT AND LIFERAFTEMBARKATION DECK. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: ESCAPE ROUTES SHALL BE MAINTAINED IN A SAFE CONDITION, CLEAR OF OBSTACLES. PSCO OBSERVED MULTIPLE EXCESSIVELY WASTED STEPS ON LADDERS ALONG EXTERIOR EMBARKATION ROUTE TO THE LIFEBOAT.
74SOLAS(09)II-2/13.1.2
40ac
01 - Certificates & Documentation › 011 - Ships Certificates › Continuous synopsis record
Issued 23 October 2025
Resolved
THE CONTINUOUS SYNOPSIS RECORD SHALL BE ISSUED BY THE ADMINISTRATION TO EACH SHIP THAT IS ENTITLED TO FLY ITS FLAG AND IT SHALL CONTAIN, AT LEAST, THE FOLLOWING INFORMATION (THE CONTINUOUS SYNOPSIS RECORD SHALL CONTAIN THE INFORMATION IN PARAGRAPHS 3.7 AND 3.10 WHEN IT IS ISSUED OR UPDATED ON OR AFTER 1 JANUARY 2009): THE REGISTERED OWNER IDENTIFICATION NUMBER. PSCO OBSERVED REGISTERED OWNERS’ IDENTIFICATION NUMBER MISSING FROM THE CURRENT CONTINUOUS SYNOPSIS RECORD. 74SOLAS(24)XI-1/5.3.7
40ac
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 October 2025
Resolved
THE RING, LINES AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK GROUND OR IN BLACK ON A LIGHT GROUND. THEY SHALL ALSO BE PERMANENTLY MARKED ON THE SIDES OF THE SHIPS TO THE SATISFACTION OF THE ADMINISTRATION. THE MARKS SHALL BE PLAINLY VISIBLE AND, IF NECESSARY, SPECIAL ARRANGEMENTS SHALL BE MADE FOR THIS PURPOSE. PSCO OBSERVED DECK LINE NOT OF CONTRASTING COLOR TO THE HULL.
66 ICLL (PROT 88) REG. 8
40ac
Lifesaving › Rescue Boat › Propulsion Engine
Issued 8 October 2014
Resolved
0615 - RESCUE BOAT - THE ENGINE STARTING SYSTEM SHALL START THE ENGINE AT AN AMBIENT TEMPERATURE OF -15 DEGREES CELSIUS WITH 2 MINUTES OF COMMENCING START PROCEDURES. WHILE CONDUCTING AN OPERATIONAL TEST OF THE RESCUE BOAT'S ENGINE THE CREW WAS UNABLE TO START AND DEMONSTRATE PROPER OPERATIONS GIVEN THE ALLOTTED TIME. SOLAS 74 (09 CONS) III/34 - LSA 5.1.1.1
Fire Fighting › Firemans Outfit › Axe
Issued 8 October 2014
Resolved
0720 - FIRE FIGHTING EQUIPMENT - PERSONAL EQUIPMENT REQUIRED BY THE FIREFIGHTER'S OUTFIT SHALL CONSIST OF AN AXE WITH A HANDLE PROVIDED WITH HIGH-VOLTAGE INSULATION. NO AXES WERE PROVIDED. SOLAS 74 (09 CONS) II-2/10.1 - FSS CH 3/2.1.1.1.5
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 October 2014
Resolved
0960 - MEANS OF ESCAPE - ON ALL SHIPS, WITHIN THE MACHINERY SPACES, EMERGENCY ESCAPE BREATHING DEVICES SHALL BE SITUATED READY FOR USE. THE EMERGENCY ESCAPE BREATHING DEVICE IN THE STORE FLAT AREA OF THE ENGINE ROOM WAS NOT CHARGED AND UNABLE TO BE USED FOR ITS INTENDED USE. SOLAS 74 (09 CONS) II-2/13.4.3.1
Construction/Loadline › Hull › Side Shell
Issued 8 October 2014
Resolved
1299 - OTHER (LOAD LINES) - SHIPS BUILT AND MAINTAINED IN CONFORMITY WITH THE REQUIREMENTS OF A CLASSIFICATION SOCIETY RECOGNIZED BY THE ADMINISTRATION MAY BE CONSIDERED TO POSSESS ADEQUATE STRENGTH. THE M/V GLADIATOR WAS UNABLE TO PROVIDE PROPER CLASSIFICATION DOCUMENTS TO PORT STATE CONTROL OFFICERS AUTHORIZING THE HULL INSERT ON THE STARBOARD SIDE NEAR CARGO HOLD NUMBER 5. ICLL 1.1
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 8 October 2014
Resolved
2099 - OTHER (SOLAS OPERATIONAL DEF.) - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT CONVENTIONS. THE PORT STATE CONTROL OFFICER DISCOVERED A FLEXIBLE PLASTIC HOSE CONNECTING THE GREY WATER FROM THE PORT SIDE ENGINE ROOM ALONG THE OVERHEAD TO THE STARBOARD SIDE INTO THE SEWAGE TREATMENT TANK.
SOLAS 74 (09 CONS) I/11
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.