MAURY USCG vessel records Sign in
← All vessels

POINTE A LA HACHE

POINTE A LA HACHE is a 1967 passenger vessel (inspected). The Coast Guard has recorded 102 inspections since 1992, most recently in May 2026, along with 120 deficiencies and 5 casualty investigations between 2011 and 2012.

Records from 1992 to 2026. Most recent: inspection, 28 May 2026.

Built
1967
Last inspected
28 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD9449
Flag
UNITED STATES
367311640
Maury page id
psix-94048

Inspections, by type

…with no type recorded3
Years with a record 28 calendar years (1992–2026)
The 102 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)142.7 ft × 60.0 ft × 9.6 ft
Registered tonnagegross 656 / net 446
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEQUITABLE EQUIPMENT COMPA · MADISONVILLE, LA, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPLAQUEMINES PARRISH, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it656 - Regulatory (Subpart C or D), Gross Ton
446 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD9449MMSI 367311640 · active · compulsorily equipped · granted 15 July 2017, expires 5 September 2027
WY2022MMSI not assigned · expired · compulsorily equipped · granted 18 April 1997, cancelled 22 September 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 102

28 May 2026 Re-Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8382492
9 April 2026 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8328130
25 November 2025 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8273685
26 September 2025 MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8230987
2 June 2025 Damage Survey · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8149867
1 April 2025 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8091747
2 January 2025 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8056702
9 October 2024 MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8004430
21 June 2024 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7939544
27 March 2024 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7885614
6 December 2023 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7834638
19 September 2023 COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7794296
27 June 2023 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7724952
14 April 2023 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7668724
3 February 2023 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7611261
24 October 2022 Damage Survey · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7582678
14 October 2022 MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7559572
9 June 2022 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7472860
12 April 2022 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7429733
5 January 2022 Deficiency Check · Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7375962
4 March 2021 Internal Structural Exam · Drydock Exam · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7155250
23 November 2020 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7100376
17 November 2020 MTSA Verification · COI Inspection · Drydock Extension
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7096646
9 November 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7092332
24 September 2020 Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7064458
22 September 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7063002
12 June 2020 Periodic Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6966431
18 March 2020 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6933234
16 March 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6928457
24 February 2020 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6914590
21 November 2019 MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6844868
27 August 2019 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6796690
11 June 2019 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6717907
14 March 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6632416
27 November 2018 COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6587291
30 August 2018 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6520087
1 June 2018 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6431412
26 February 2018 Administrative Inspection · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6362177
20 November 2017 Examination of Repairs · Deficiency Check · Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6310380
15 September 2017 Periodic Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6265814
15 September 2017 Damage Survey · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6269571
16 June 2017 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6175921
10 March 2017 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6099852
2 December 2016 COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6049903
16 September 2016 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5999669
10 June 2016 Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5899988
18 March 2016 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5833907
19 June 2014 Deficiency Check · Damage Survey · Periodic Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4890405
19 July 2012 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4374144
23 January 2012 Deficiency Check · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4223874
12 September 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4142801
3 August 2011 Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4097614
22 July 2011 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4079978
14 February 2011 DAPI Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3937922
3 February 2011 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3932957
26 October 2010 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3873503
14 January 2010 DAPI Audit · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3660877
22 July 2009 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3541319
22 April 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3458315
17 April 2009 COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3451607
27 January 2009 Examination of Repairs · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3397590
27 October 2008 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3348729
29 July 2008 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3270551
11 April 2008 Deficiency Check · Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3179025
1 February 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3134870
11 January 2008 Periodic Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3126548
27 September 2007 Periodic Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3062696
27 July 2007 Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2991623
23 February 2007 Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2876367
4 August 2006 Re-Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2735997
14 March 2006 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2601463
27 November 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2582619
17 June 2005 Periodic Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2393748
12 April 2005 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2332518
14 March 2005 Periodic Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2309560
15 December 2004 COI Inspection · MTSA Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2259627
22 September 2004 COC-CVE Quarterly
Type not classified · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2201916
3 August 2004 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2154968
18 June 2004 Re-Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2102376
19 April 2004 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2047411
16 March 2004 Quarterly Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2025814
2 February 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2005493
20 January 2004 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1988547
17 December 2003 COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1965521
26 November 2003 Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1955016
17 October 2003 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1930525
24 September 2003 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1912197
17 September 2003 Quarterly Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1907255
18 June 2003 Quarterly Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1820507
19 March 2003 Quarterly Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1759440
18 December 2002 COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1720453
11 October 2002 Quarterly Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1688381
17 June 2002 Quarterly Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1632207
27 March 2002 Quarterly Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1597988
27 December 2001 COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1473899
14 September 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1443249
15 June 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1391618
26 March 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1462200
2 April 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 160362
25 January 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448502
14 May 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1391849
3 October 1992 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1245440

Deficiency record · 120

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 April 2026 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Port gen has oil leaks and breather tube leaking oil on windings. 46 CFR 72.03-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2026
Resolution: Recieved photgraphic evidence that vessel had fixed breather tube and oil leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 June 2025 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident or a defect is discovered which affects the safety of the vessel. Vessel experienced loss of starboard engine maneuverability while mooring up Belle Chasse Ferry Landing-West Bank, MM 76 and carrying 28 passengers. Vessel to provide document attesting to cause and affect to include operational testing to the satisfactory of attending CG Marine Inspector prior to carriage of passengers. 46 CFR 71.40-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2025
Resolution: Starboard shaft replaced and port shaft reconditioned. Both re-installed with bearings. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 October 2024 Resolved
Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks, and safety controls. MI found both MDE's low L/O psi shutdown's outside of parameter IAW approved PSTPs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2024
Resolved 16 October 2024
Resolution: Received tech report. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 February 2023 Resolved
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. On systems in which the CO2 cylinders are not within the protected space, these instructions must also include a schematic diagram of the system and instructions detailing alternate methods of discharging the system should the manual release or stop valve controls fail to operate. Each control valve to branch lines must be marked to indicate the related space served. MI thoroughly read posted instructions and determined that the listed local operating instructions may inadvertently bypass all installed safety and shut down systems. Vessel operator is required to have the required instructions validated by the servicing company and corrected as necessary. The issuing office understands that the servicing company is scheduled to attend vessel on 07FEB23. 46CFR76.15-10 16c.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2023
Resolved 8 February 2023
Resolution: New instructions and valve labels posted and satisfactory pressure test of branch lines conducted.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 18 October 2021 Resolved
On vessels required by 112.05-5(a) to have a temporary emergency power source, the following emergency lighting and power loads must be arranged so that they can be energized from the temporary emergency power source: Lighting, including… muster stations. There was no emergency lights installed on the aft deck in the vicinity of the muster station for the IBAs. 46 CFR 112.15-1(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Emergency Light was added to the embarkation are on the stern of the vessel near liferafts.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 18 October 2021 Resolved
General emergency alarm signal must: Be located in passenger and crew quarter areas where they can alert persons in spaces. The main deck port and starboard general alarms were not operating at the time of inspection. 46 CFR 113.25-9(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Port and stbd main deck general alarm bells are now functioning.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 18 October 2021 Resolved
Internal combustion engine exhausts, boiler and galley uptakes and similar source of ignition shall be kept clear of and suitably insulated from any woodwork or other combustible matter. The starboard main engine exhaust has missing lagging, exposing hot piping. 46 CFR 72.03-10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Stbd main engine exhaust lagging was installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 October 2021 Resolved
The general construction of the vessel shall be such as to minimize ire hazards insofar as is reasonable and practicable. There was excessive oily mixtures found below the main and auxiliary engines in the engine room. 46 CFR 72.03-5(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Oily mixture was removed from engine bay's underneath engines.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 18 October 2021 Resolved
If your vessel’s Certificate of Inspection is renewed annually, the marine inspector must check the stings of the safety or relief valves on all pressure vessels, except cargo tanks, at each inspection for certification. The vessel has three air receivers on board with three separate relief valves. There is no record of the relief valves having been tested to their set pressure. Additionally one of the relief valves in the engine room was painted over. Provide reports attesting to the accuracy of the relief valve’s set pressures. 46 CFR 61.10-5(i)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Relief valves for machinery space pressure vessels that was painted over was replaced new.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 18 October 2021 Resolved
Each machinery space must be ventilated to ensure that, when machinery or boilers are operating at full power in all weather including heavy weather, an adequate supply of air is maintained for the operation of the machinery and for the safety, efficiency, and comfort of the crew. The port engine room supply fan is currently not operational. The crew has been opening an access window on the port side of the superstructure to allow air supply to the engine room. 46 CFR 58.01-45
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2021
Resolved 14 January 2022
Resolution: Verified the port engine compartment supply fan had been replaced.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 October 2021 Resolved
Drills must, as far as practicable, be conducted as if there were and actual emergency. During the man overboard drill, the crew did not follow the vessel’s station bill located in the Approved Shipboard Safety Management and Contingency Plan. Specifically, the crew did not keep communications with the master, nor did they designate a lookout to monitor the location for the man overboard as stated in the plan. The crew, along with attending marine inspectors, reviewed the station bill and requirements for each crew member during the drill. Corrected on the spot. 46 CFR 199.180(c)
Action required: 10 - Deficiency Rectified
Resolved 18 October 2021
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 June 2020 Resolved
#1 SSDG low L/O did not shut down the prime mover when tested.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2020
Resolved 12 June 2020
Resolution: Vessel rep provided video of the low L/O shut down working correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 June 2020 Resolved
#1 SSDG Overspeed trip did not shut down the prime mover when tested.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2020
Resolved 12 June 2020
Resolution: Vessel rep submitted video of the overspeed trip working correctly.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 12 June 2020 Resolved
Each passenger vessel must have a public address system capable of broadcasting separately or collectively to the following stations:(g) Accommodation spaces and service spaces. Main deck accommodation space does not have a P/A system speaker and cannot be heard when general alarm is activated or announcements are made. Vessel's company shall rectify in a way as the general alarm and P/A system can be heard by passengers in accommodation space when activated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 16 July 2020
Resolution: Company rep submitted pictures of an installed P/A system in the space.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 February 2020 Resolved
"All lifesaving appliances and arrangements on passenger vessels must be IAW 46 CFR Subchapter W (Lifesaving Appliances & Arrangements). Weekly inspections and tests: Each survival craft, rescue boat, and launching appliance must be visually inspected to ensure its readiness for use; Each lifeboat engine and rescue boat engine must be run ahead and astern for 3 minutes; The general alarm system must be tested." Upon talking with the master, crew, and company security officer, weekly visual checks of the general alarm, rescue boat and launching appliance, and the 4 on board inflatable liferafts are being done at variable intervals, but not being done at these required weekly intervals. Only logbook entries are seen are at monthly intervals, most two recent entries were 4MAR2020 and 9FEB2020. Conduct weekly visual inspections of all stated lifesaving items & weekly rescue boat engine test and appropriately log, as weekly checks would have identified the 4 liferaft hydrostatic release units were 1 month expired (Feb 2020). Deficiency will stay open for 3 months to be verified at the next quarterly reinspection. Ensure all Masters are aware of this. 46 CFR 70.28-1 and 46 CFR 199.190(d) and (e)
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 June 2020
Resolved 12 June 2020
Resolution: Vessel created a weekly check list for the lifedaving items.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 February 2020 Resolved
"Each lifesaving appliance, including lifeboat equipment, must be inspected monthly using the checklists required under paragraph (b)(1)(i) of this section to make sure the appliance and the equipment are complete and in good working order. A report of the inspection, including a statement as to the condition of the equipment, must be recorded in the vessel's official logbook." Upon talking with the master, crew, and company security officer, they stated there are no monthly lifesaving appliance inspection checklists for the rescue boat, rescue boat launching appliance (davit), and 4 inflatable liferafts. Create three separate & detailed checklists to be used for the inspection of these different lifesaving equipment items. Furthermore, the 4MAR2020 and 9FEB2020 logbook entries are related to lifesaving drills, not the actual equipment/inventory checks, ensure this monthly check is conducted and properly logged. Create these checklists and provide them for our review no later than 12MAR2020. 46 CFR 70.28-1 and 46 CFR 199.190(d) and (e)
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 March 2020
Resolved 12 March 2020
Resolution: see narrative
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 June 2019 Resolved
Prior to getting this vessel underway all missing void hatch gaskets must be replaced, gaskets that are not serviceable must be replaced as well. Excessive waster is to be removed for the void spaces where a lack of a gasket caused water to enter the space
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 18 June 2019
Resolved 11 June 2019
Resolution: All gaskets replaced as necessary and voids de watered.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 11 June 2019 Resolved
Prior to getting the vessel underway, all sounding tube caps on the main deck must be made usable, currently many cannot be opened and have not been opened for quite some time. Also on the main deck the caps for the bilge and ballast suction valves must be made usable.
Action required: 60 - Rectify deficiencies prior to movement
Due 18 June 2019
Resolved 11 June 2019
Resolution: All tubescaps and valve caps removed, cleaned and operated satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 November 2018 Resolved
Each generator must have an overspeed device that is independent of the normal operating governor and adjusted so that the speed cannot not exceed the maximum speed by more than 15 percent. Port generator overspeed device failed to shutdown engine completely. Generator ran at 600 RPM's (without load) while air shutdown was engaged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2018
Resolved 3 December 2018
Resolution: Engineers proved proper operation of overspeed device.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 November 2018 Resolved
Each equipment-grounding conductor must be sized in accordance with Section 250.122 of NFPA NEC 2002. STBD generator is missing grounding strap. Install appropriate grounding strap.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2018
Resolved 3 December 2018
Resolution: New grounding strap was installed IAW manufacturers recomendations.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 27 November 2017 Resolved
Crew could not follow the posted instructions. Need to either update the instructions to make it easier to follow or train the crew on the differences on the two different sets of instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 12 January 2018
Resolution: Vessel replaced signage in CO2 room, providing clarity. Conducted walk through with on duty ENG, was knowledgeable in operation and procedures.
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 November 2017 Resolved
Remove fluids in e/r batt install. Repair holed batt box aft of bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 12 January 2018
Resolution: Battery box was thoroughly cleaned out.
Engineering › Pressure Vessel › Pressure Gauge
Issued 27 November 2017 Resolved
Replace pressure gauge would not display the MAWP of the pv or the relief valve settings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 12 January 2018
Resolution: Pressure gauge was replaced with proper guage.
Electrical › Electric Generation Source (service) › Generator
Issued 15 September 2017 Resolved
Stbd SS Generator reported OOC. Prior to placing back in service, MI must attend for partial survey.
Action required: 705 - Other - as specified
Resolved 15 December 2017
Resolution: Attended vessel, all testing of newly installed generator was completed to satisfaction of attending MI.
Engineering › Compressed Air System (control) › Piping
Issued 15 September 2017 Resolved
Shutoff valve installed between electric air compressor and the air reciever, thereby leaving a section of the supply piping unprotected (relief valve on compressor was set higher than the air reciever).
Action required: 705 - Other - as specified
Due 15 October 2017
Resolved 23 October 2017
Resolution: Recieved pictures of the new relief valves installed.
Engineering › Compressed Air System (control) › Piping
Issued 15 September 2017 Resolved
Shutoff valve installed between deisel engine powered air compressor and the air reciever, thereby leaving a section of the supply piping unprotected (relief valve on compressor was set higher than the air reciever).
Action required: 705 - Other - as specified
Due 15 October 2017
Resolved 23 October 2017
Resolution: Recieved pictures of the new relief valves installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 15 September 2017 Resolved
High Pressure CO2 bottle for fire-suppression system was stored directly on the deck in the engine room.
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 18 October 2017
Resolution: Recieved picture of CO2 bottle resting on newly installed evavation grating.
Lifesaving › Lifebuoys › Stowage
Issued 10 March 2017 Resolved
Lifering filled with water. Replace lifering.
Due 10 March 2017
Resolved 10 March 2017
Resolution: Life ring replaced.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 March 2017 Resolved
Missing 1 required adult lifejacket from Stbd side forward stowage box - only 49 in box marked for 50. Replace the missing life jacket.
Due 10 March 2017
Resolved 10 March 2017
Resolution: Missing jacket was placed in wrong location - found in midship accomodation space cage - moved back to proper location. All life jacket storage boxes now have correct number of jackets as labels indicate.
Communications › Alarms/Indicators › General Alarm
Issued 10 June 2016 Resolved
Machinery space GA light not working
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 June 2016
Resolution: fixed
Engineering › Bilge Water Management System › Strainer
Issued 10 June 2016 Resolved
no strainer on e/r bilge suction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 June 2016
Resolution: expanded metal installed.
Engineering › Lubricating Oil Service System › Piping
Issued 18 March 2016 Resolved
1. Repair oil leak on auxiliary engine low oil pressure sending unit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 18 March 2016
Resolution: Resolved prior to completion of the inspection.
Stability › Watertight Integrity › General
Issued 19 June 2014 Resolved
1. The vessel is not allowed to operate carrying passengers until proper repairs have been made to a fracture in the rudder compartment hull plate below the port access ladder, and has been inspected by a USCG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2014
Resolved 22 June 2014
Resolution: Visually Inspected 3X5 insert, conducted a hydro test at 45 psi.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 19 June 2014 Resolved
2. This vessel must be towed to Belle Chasse maintenance landing with 2 extra portable pumps on board and the space constantly monitored during the transit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2014
Resolved 22 June 2014
Resolution: Vessel was towed to Bollinger Algiers for repair, repair was completed and inspected.
Construction/Loadline › Hull › Hull Plating
Issued 19 June 2014 Resolved
4. Crop and renew to good metal a hull plate in way of the fracture that complys with NVIC 7-68 steel hull repair guide, and Call the Coast Guard to inspect the repairs.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 22 June 2014
Resolution: Visually inspected 3X5 insert and hydro tested with 45 psi. See narative.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 19 June 2014 Resolved
3. Transit to Bollinger shipyard must be by towing as well as per item 2.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2014
Resolved 22 June 2014
Resolution: Vessel towed successfully to Bollinger Algiers for repairs, repairs completed and inspected.
Electrical › Electric Supply System (service) › Cable
Issued 19 June 2014 Resolved
Properly bundle wires/cables on mast located between stacks. Properly mount all wires.
Due 27 July 2014
Resolved 10 July 2014
Resolution: All wires were bundled properly
Electrical › Electrical Distribution System (service) › Switchboard
Issued 19 June 2014 Resolved
Portside main switchboard breaker has no data plate, identify breaker and install proper data plate.
Due 27 July 2014
Resolved 18 July 2014
Resolution: Vessel labeled missing breaker plate.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 19 June 2014 Resolved
Port main engine starter solenoid missing lock for coils. Install correct coil lock as per stb side engine.
Due 27 July 2014
Resolved 10 July 2014
Resolution: Provided lock for coils
Stability › Watertight Integrity › General
Issued 19 June 2014 Resolved
Both " soft patch" bolted hatches leading to the engine room are leaking, allowing water to enter engine room. Properly seal both of these hatches and prove by a hose test.
Due 27 August 2014
Resolved 26 August 2014
Resolution: Gaskets were replaced for both hatches and hose tested satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 19 June 2014 Resolved
Water leak from stb "soft patch" hatch is dripping directly on an electrical light fixture. Disconnect this light fixture until leak is repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2014
Resolved 27 June 2014
Resolution: Light fixture was disconnected from breaker panel.
Engineering › Fuel Oil Service System › Hose
Issued 19 June 2014 Resolved
Port generator F/O hose at starter was pinched and worn through outer rubber sleeve and started to cut into wire mesh. Replace this fuel hose. Also at the end of this hose under the engine it appears that the pipe fittings are leaking. Repair these as well.
Due 27 July 2014
Resolved 10 July 2014
Resolution: Fuel hose was replaced and re routed.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 19 June 2014 Resolved
Water leaking in passenger area overhead is leaking on into a light fixture with water noted on lens. Disconnect this light fixture until all overhead water leaks have been repaired and hose tested.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2014
Resolved 27 June 2014
Resolution: Light fixture was disconnected from breaker panel
Stability › Weathertight Integrity › General
Issued 19 June 2014 Resolved
Passenger area overhead has obvious hole due to water leaking into the new ceiling tiles. Find and repair water leaks.
Due 27 July 2014
Resolved 18 July 2014
Resolution: Received technician''s report attesting to proper repair of A/C unit. That was leaking
Engineering › Steering Gear System › Pump
Issued 19 June 2014 Resolved
Replace #1 steering pump pressure gauge.
Due 27 July 2014
Resolved 10 July 2014
Resolution: Replaced #1 steering pressure gauge.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 July 2012 Resolved
Repair the loose wires to the ventilation shutdown system currently wire missing from relay which the CO2 sys pressure switch is suppose to shut down the vents. This was corrected during the inspection. Entered as 835 to document deficiency.
Action required: 705 - Other - as specified
Due 16 July 2012
Resolved 16 July 2012
Fire Fighting › Ventilation Systems › Operating Controls
Issued 16 July 2012 Resolved
Dterrmine the reason the CO2 pressure switch was in the off position for the ventilation shut down and the ventilation was still running in the engine room. The problem was the wire missing from the relay that shuts down the ventilation breaker, corrected the same day, this 835 entered to docnument the problem.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2012
Resolved 16 July 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 January 2012 Resolved
Provide guard for light & fan above stove in galley.
Due 23 February 2012
Resolved 20 March 2012
Engineering › Fuel Oil Service System › Hose
Issued 23 January 2012 Resolved
Replace port reduction gear oil hose to meet SAE standard J-1942
Due 23 February 2012
Resolved 20 March 2012
Engineering › Fuel Oil Service System › Hose
Issued 23 January 2012 Resolved
Provide chafing gear for fuel hose on PME
Due 23 February 2012
Resolved 20 March 2012
Documentation › Logs/Records › Logbook (official)
Issued 22 July 2011 Resolved
The SSMCP drills are being conducted IAW the vessels plan. Conduct drills & properly log in the SSMCP record keeping log. Drills were logged in vessels Deck Log.
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 13 October 2011
Engineering › Steering Gear System › Rudder Stock
Issued 26 October 2010 Resolved
Make repairs to the Port rudder stock. Port rudder stock bolts were loose causing the rudder stock to shift back and forth as rudders were moved.
Condition: Improper Installation
Due 5 November 2010
Resolved 5 November 2010
Engineering › Steering Gear System › Feedback Unit
Issued 26 October 2010 Resolved
Make repairs to the Stbd rudder feedback rod. Feedback rod has been bent after coming into contact with tiller arem.
Condition: Improper Installation
Due 5 November 2010
Resolved 5 November 2010
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 26 October 2010 Resolved
Make repairs to the 32 volt ground detection panel in the engineroom. Ground indicator lights are inoperable.
Due 2 November 2010
Resolved 5 November 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 26 October 2010 Resolved
Install longer chain on CO2 remote pull station. Chains are too short, not allowing enough chain to reach the pull station to break glass.
Due 5 November 2010
Resolved 5 November 2010
Construction/Loadline › Structures › Manhole
Issued 26 October 2010 Resolved
Break loose all maindeck hatches to ensure hatches are not froozen.
Condition: Improper/Lack of Maintenance
Due 2 November 2010
Resolved 5 November 2010
Electrical › Electric Supply System (service) › Battery Conductor
Issued 26 October 2010 Resolved
Shorten negative battery cable in engineroom. Cable sheathing is missing exposing the wire conductor.
Due 2 November 2010
Resolved 5 November 2010
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 17 April 2009 Resolved
1. To be completed prior to 17May09: Steering gear alarm does not sound in the pilot house and the steering gear indicator lights will not work. The alarm must be operational prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2009
Resolved 17 April 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 17 April 2009 Resolved
2. To be completed prior to 17May09: CO2 system for the engine room, correct instructions and drawing to reflect the current time delay time of 25 seconds, and repair or replace thw pressure swithc for the exhaust ventilation that is currently not working. Prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2009
Resolved 17 April 2009
Electrical › Electric Generation Source (service) › Generator
Issued 27 January 2009 Resolved
Repair oil leaks on both ship's generator prime movers and clean oil from both generator units.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2009
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 27 January 2009 Resolved
Prove proper operation of ground fault detector.
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 17 February 2009
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 27 October 2008 Resolved
Prove the proper installation of MDE crankcase emission filters in accordance with manufacturers instructions.
Due 27 November 2008
Resolved 17 April 2009
Engineering › Steering Gear System › Rudder
Issued 11 April 2008 Resolved
observe rudder packing does not take on water while underway.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2008
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 1 February 2008 Resolved
Prove proper operation of ground detection equipment
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 1 February 2008
Communications › Internal Communications System › Sound-powered Telephone
Issued 1 February 2008 Resolved
Prove proper operation of sound powered phone in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 1 February 2008
Resolution: Replaced unit, works OK
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 1 February 2008 Resolved
Missing exhaust lagging on stbd engine
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 1 February 2008
Resolution: Lagging installed
Electrical › Electric Supply System (service) › Cable
Issued 1 February 2008 Resolved
Install cable supports for electrical wiring on both main engines
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 1 February 2008
Resolution: Cables properly bundled and suported.
Engineering › Lubricating Oil Service System › Gauge
Issued 1 February 2008 Resolved
No gauge on LO alarm and shutdown for main engines and aux gen.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 1 February 2008
Resolution: Gauge installed
Construction/Loadline › Hull › Side Shell
Issued 1 February 2008 Resolved
Crop and renew approx 4' x 18" plate section of stbd aft bulwark.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 February 2008
Resolved 11 March 2008
Construction/Loadline › Structures › Ventilators
Issued 1 February 2008 Resolved
Crop & Renew steering space vent pipe.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 February 2008
Resolved 11 March 2008
Resolution: Renewed deck collar only. The vent pipe was in good condition.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 11 January 2008 Resolved
Prove proper operation of ground detection system on main switchboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 11 January 2008
Communications › Internal Communications System › Sound-powered Telephone
Issued 11 January 2008 Resolved
Prove proper operation of sound powered phone and annunciator in the engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 1 February 2008
Resolution: Replaced unit, works OK
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 11 January 2008 Resolved
Properly install the exhaust lagging on the STBD generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 1 February 2008
Resolution: Lagging installed
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 January 2008 Resolved
Provide cable supports for the electrical wiring on both main diesel engines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 1 February 2008
Resolution: Cables properly bundled and suported.
Engineering › Lubricating Oil Service System › Gauge
Issued 11 January 2008 Resolved
Provide test kit for testing the low l/o alarm and shutdown for main diesel engines and generators.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 1 February 2008
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2008 Resolved
Crop and renew approximately 4' X 18" plate section of STBD aft bulwark.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 11 March 2008
Construction/Loadline › Structures › Ventilators
Issued 11 January 2008 Resolved
Crop and renew steering space vent pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 11 March 2008
Resolution: Renewed deck collar only. The vent pipe was in good condition.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 27 July 2007 Resolved
Apply directional arrows to remote fuel shut-offs located on both port and starboard.
Action required: 705 - Other - as specified
Due 27 August 2007
Resolved 14 September 2007
Resolution: Directional arrows applied to fuel shut-offs.
Construction/Loadline › Hull › Weld
Issued 27 July 2007 Resolved
Repair 16" fracture on vertical weld forward of starboard fuel shut-off.
Action required: 705 - Other - as specified
Due 27 August 2007
Resolved 14 September 2007
Resolution: Fracture gouged and re-welded.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 July 2007 Resolved
Repair access door under bridge control panels on portside.
Action required: 705 - Other - as specified
Due 27 August 2007
Resolved 14 September 2007
Resolution: Access door re-hung.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 27 July 2007 Resolved
Provide copy of CO2 servicing report to USCG.
Action required: 705 - Other - as specified
Due 27 August 2007
Resolved 30 July 2007
Resolution: Sat. CO2 servicing report provided to USCG.
Communications › Radio Communications › VHF Radiotelephone
Issued 27 July 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 27 September 2007
Resolved 27 September 2007
Resolution: Vessel rep provided proof of valid license.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 July 2007 Resolved
Replace expired consumable in First Aid Kit.
Action required: 705 - Other - as specified
Due 27 August 2007
Resolved 14 September 2007
Resolution: Entire first aid kit replaced.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 27 July 2007 Resolved
Determine why breakers labeled "spare" are in "on" position in starboardside circuit box on bridge.
Action required: 705 - Other - as specified
Due 27 August 2007
Resolved 14 September 2007
Resolution: Spare breakers all switched to "off" position.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 27 July 2007 Resolved
Label amperage of circuits in portside circuit box on bridge.
Action required: 705 - Other - as specified
Due 27 August 2007
Resolved 14 September 2007
Resolution: Amperage labeled.
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2007 Resolved
Install deck insert in way of temporary repair above starboard rudder stock.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 27 July 2007
Resolution: Deck insert installed IWO temp repair above starboard rudder stock.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 23 February 2007 Resolved
Prove operation of ground detection system.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 27 July 2007
Resolution: Sat. operation of ground detection system proven.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 14 March 2005 Resolved
Crop and renew wasted angle iron beneath port shaft seal.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 11 April 2005
Resolution: Verified proper replacement of angle iron.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 18 June 2004 Resolved
Prove proper operation of the ground fault system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 July 2004
Resolved 3 August 2004
Resolution: Proved operation.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 18 June 2004 Resolved
Replace circut breaker for life boat in eng rm switchboard
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 July 2004
Resolved 3 August 2004
Resolution: Installed new circuit breaker.
Electrical › Lighting (service)
Issued 16 March 2004 Resolved
Mount lights in steering compt. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 20 April 2004
Engineering
Issued 16 March 2004 Resolved
Remove excessive water in steering compt. LEGACY COMPONENT DESC: Compartment
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 20 April 2004
Engineering › Steering Gear System
Issued 16 March 2004 Resolved
Install cotter pins where jockey bar meets tiller arms in steering compt. LEGACY COMPONENT DESC: Pin
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 20 April 2004
Engineering › Steering Gear System
Issued 16 March 2004 Resolved
Renew bushing where port tiller arm connects to tie rod. LEGACY COMPONENT DESC: Bushing
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 20 April 2004
Engineering › Steering Gear System
Issued 16 March 2004 Resolved
Tighten center roller support for tie rod. LEGACY COMPONENT DESC: Support Bar
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 20 April 2004
Construction/Loadline › Structures
Issued 16 March 2004 Resolved
Re-gasket centerline gasket for steering compt hatches LEGACY COMPONENT DESC: Scuttle
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 20 April 2004
Engineering › Diesel Engine (propulsion-electric)
Issued 16 March 2004 Resolved
Replace stbd MDE pneumatic air starter hose. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 20 April 2004
Engineering
Issued 16 March 2004 Resolved
Install chafing gear on stbd transmission oil lines.
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 20 April 2004
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 16 March 2004 Resolved
Replace hose on CO2 semi-portable extinguisher. LEGACY COMPONENT DESC: Discharge Hose/Tube
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 20 April 2004
Engineering › Generator (propulsion/auxiliary-electric)
Issued 16 March 2004 Resolved
Prove proper operation of both SSDG overspeed shutdowns. Engineroom is to be manned all times until corrected. LEGACY COMPONENT DESC: Overspeed Trip
Action required: 705 - Other - as specified
Due 17 March 2004
Resolved 20 April 2004
Engineering › Bilge Water Management System
Issued 16 March 2004 Resolved
Repair stbd bilge knife switch for motor controller. LEGACY COMPONENT DESC: Controller
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 20 April 2004
Accommodation/Occupational Safety › Cooking Systems
Issued 16 March 2004 Resolved
Clean excessive grease from crew lounge stove/oven. LEGACY COMPONENT DESC: Stove
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 19 April 2004
Accommodation/Occupational Safety › Cooking Systems
Issued 16 March 2004 Resolved
Close open burner spaces on oven. LEGACY COMPONENT DESC: Burners
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 19 April 2004
Electrical › Electrical Distribution System (service)
Issued 16 March 2004 Resolved
Repair electrical cable for A/C on bridge (going into receptacle) and Paris radio electrical cable. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 19 April 2004
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 March 2004 Resolved
Install emergency light in crew lounge. LEGACY COMPONENT DESC: Emergency Lighting
Action required: 705 - Other - as specified
Due 17 April 2004
Resolved 19 April 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 17 December 2003 Resolved
Renew fire extinquisher bracket for station #7 LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2004
Resolved 20 January 2004
Resolution: Noted and tested newly installed bracket, sat.
Lifesaving › Lifebuoys
Issued 17 December 2003 Resolved
Renew stern ring buoy. Current ring buoy is cracked. LEGACY COMPONENT DESC: Quantity
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 January 2004
Resolved 20 January 2004
Resolution: Noted newly installed ring buoy.
Communications › Audible Communications
Issued 17 December 2003 Resolved
Prove proper operation of aft loud speaker. LEGACY COMPONENT DESC: SPD (Other)
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 January 2004
Resolved 20 January 2004
Resolution: Noted proper audible operation of aft loudspeaker.
Electrical › Electrical Distribution System (service)
Issued 17 December 2003 Resolved
Blank off opening in engine alarm panel. LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 January 2004
Resolved 20 January 2004
Resolution: Panel properly blanked off.
Electrical › Electrical Distribution System (service)
Issued 17 December 2003 Resolved
Replace missing port engine oil alarm switch junction box cover. LEGACY COMPONENT DESC: Junction Box
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 January 2004
Resolved 20 January 2004
Resolution: Noted installed junction box cover.
Lifesaving › Buoyant Apparatus
Issued 17 December 2003 Resolved
Relaminate three life floats.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 January 2004
Resolved 20 January 2004
Resolution: Noted fresh lamination and newly affixed reflective tape.
Navigation › Piloting/Steering
Issued 17 December 2003 Resolved
Prove proper operation of follow-up steering for #2 steering pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 January 2004
Resolved 20 January 2004
Resolution: Tested steering in the follow-up mode on the number two pump sat.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 17 December 2003 Resolved
Investigate and repair lube oil leak between port engine and reduction gear. LEGACY COMPONENT DESC: Crankshaft
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 January 2004
Resolved 20 January 2004
Resolution: Engineer indicated the seal was replaced eliminating the leak.
Engineering › Steering Gear System
Issued 17 September 2003 Resolved
Renew hydraulic hoses on both steering pumps and fix leak at junction box. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 17 October 2003
Resolution: Repaired hoses and components.
Lifesaving › Lifebuoys
Issued 17 September 2003 Resolved
Renew one 12 man life float. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 24 September 2003
Lifesaving › Buoyant Apparatus
Issued 17 June 2002 Resolved
Reroute lifefloat line through holder so bitter end will freely pay out.
Condition: Improper Installation
Due 17 July 2002
Resolved 26 June 2002
Resolution: Done
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 17 June 2002 Resolved
Replace CO2 instruction diagram I.A.W CFR 76.15-10 h LEGACY COMPONENT DESC: Operating Controls
Condition: Design Flaw
Due 17 July 2002
Resolved 26 June 2002
Resolution: Done
Lifesaving › Lifebuoys
Issued 17 June 2002 Resolved
Permanently mark each lifebuoy stowage position with the words "LIFEBUOY" I.A.W CFR 199.70 a (1) (iii) LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Unknown
Due 17 July 2002
Resolved 26 June 2002
Resolution: Done
Lifesaving › Lifebuoys
Issued 17 June 2002 Resolved
Ensure all lifebuoy lights are not attached to liferings.
Condition: Unknown
Due 17 July 2002
Resolved 26 June 2002
Resolution: Done
Lifesaving › Lifebuoys
Issued 17 June 2002 Resolved
Ensure all lifebuoy lines are 2x the distance to the water. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Placed in Improper Service
Due 17 July 2002
Resolved 26 June 2002
Resolution: Done

Casualty record · 5

1 June 2011Routine · role: Involved in a Marine Casualty · activity 4037392
21 June 2011Routine · role: Involved in a Marine Casualty · activity 4062661
22 June 2011Routine · role: Involved in a Marine Casualty · activity 4060637
8 November 2011Routine · role: Involved in a Marine Casualty · activity 4185472
18 April 2012Routine · role: Involved in a Marine Casualty · activity 4293119
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.