Records from 1987 to 2025. Most recent: inspection, 19 November 2025.
Inspection history · 93
19 November 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8270661
12 November 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8266823
16 September 2024
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8003161
15 November 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7825435
18 September 2023
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7769234
10 May 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7685507
7 September 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7553617
12 November 2021
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7349960
14 September 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7057516
4 November 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6849404
24 September 2019
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6819467
18 September 2018
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6542251
15 November 2017
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6307076
8 November 2017
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339571
26 October 2017
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6295617
1 November 2016
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6032997
12 November 2015
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5761876
26 October 2015
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5751147
8 November 2010
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3887345
28 January 2010
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3671271
24 November 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3368855
4 November 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3356988
22 September 2008
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3329993
21 August 2008
Inclining Experiment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3321076
13 December 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3115462
16 March 2007
Administrative Inspection · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2889017
25 April 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2632826
14 November 2005
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2534095
11 May 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2355188
4 May 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2058664
26 January 2004
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1992605
12 November 2003
Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1946212
22 April 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1838594
17 July 2002
Excursion Permit
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1647864
4 July 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1647143
22 April 2002
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1607948
20 November 2001
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1474564
15 May 2001
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1064992
8 May 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1399611
31 May 2000
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1457807
20 March 2000
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1047836
23 November 1999
Hull Examination · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1375972
7 July 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1092639
9 June 1999
Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 1506352
16 April 1999
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 792266
23 June 1998
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1127299
4 June 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126713
15 December 1997
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 779916
19 November 1997
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1108107
6 August 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 782229
23 July 1997
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1115177
19 July 1997
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 780205
13 May 1997
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1119179
15 May 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1082165
15 April 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1080160
16 November 1995
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1187361
6 July 1995
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 882791
2 June 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 874438
28 April 1995
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1175472
29 April 1994
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1169002
14 April 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 857489
11 April 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 131964
28 December 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 850951
12 November 1993
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1156096
7 September 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1140129
12 July 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 843935
7 May 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1149580
23 April 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 833754
20 April 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 839932
20 August 1992
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1253199
17 June 1992
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1256607
28 April 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1264842
15 April 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1268734
30 March 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1257997
21 February 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 950531
15 October 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1248671
29 June 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1214502
20 June 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1240942
18 June 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 929644
7 June 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1214758
17 May 1990
Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1241482
3 February 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1231669
6 November 1989
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 928429
24 October 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1351107
28 June 1989
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 893087
15 June 1989
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1338177
9 November 1988
COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1207295
5 May 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1345456
22 April 1988
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1341717
16 January 1988
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1013691
5 November 1987
Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1021025
9 July 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1016249
1 July 1987
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1015543
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 November 2025
Resolved
Life ring must be marked with Type II retrorelective material approved IAW 46 CFR 164.18. Replace reflective tape on both lifebuoys on wheelhouse.
46 CFR 185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2025
Resolved 25 November 2025
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 16 September 2024
Resolved
The main and auxiliary steering apparatus shall be tested by operation and the inspector shall examine the mechanism thereof throughout its length. While testing the operations of the steering system, inspectors noticed the rudder angle indicator for the steering system was not functioning. Make repairs to the rudder angle indicator in accordance with manufactures instructions.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2024
Resolution: Vsl rep provided video evidence of the steering system working as designed, sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 15 November 2023
Resolved
Porthole on starboard side is wasted and needs to be repaired. C/R to good metal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2023
Resolved 4 December 2023
Resolution: Vessel cropped and repaired to good metal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 September 2022
Resolved
"Each ring life buoy must be of an approved type, constructed in accordance with subpart 160.050 of this chapter." MI noted the vessel's name and hailing port stenciled on all ring life buoys to be peeling off/faded. Ring buoys should be re-stenciled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2022
Resolved 12 September 2022
Resolution: Operate bought new vinyl stickers for life buoy labling
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 September 2022
Resolved
"Service use of distress signals shall be limited to a period of 3 years from the date of manufacture." MI noted expired flares.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2022
Resolved 12 September 2022
Resolution: owner bought new flares that meet sub Q specification.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2022
Resolved
"All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection." Incoming shore power cable coming into the ship's no. 1 service generator breaker was noted and being chafed, exposed, and causing an arch within the switch board.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 September 2022
Resolved 12 September 2022
Resolution: new wire was spliced into switch board and properly insulated
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Bilge alarm/float switch connection is not in an enclosure.
46CFR183.05-50(b) (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 1 October 2019
Resolution: Received photos rectifying the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019
Resolved
All lights, receptacles and switches exposed to the weather deck shall be watertight and on vessels operating in salt water, shall be constructed of corrosion-resistant material. Replace several broken or missing receptacles on the 1st and 2nd deck.
46 CFR 183.05-35 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 1 October 2019
Resolution: Received photos rectifying the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Remove the dead end wires located under bridge console, in the liquor room and under the steering gear ladder or place them inside enclosures.
46 CFR 183.05-50(b)(OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 1 October 2019
Resolution: Received photos rectifying the deficiency.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 September 2019
Resolved
"L" Vessels shall comply with the provisions of sub chapter F for vital systems. Replace the steering gear tank cross connection hose.
46 CFR 182.40-5 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 2 October 2019
Resolution: Received photos clearing 01 deficiency.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 24 September 2019
Resolved
Penetrations and openings in watertight bulkheads in a vessel less than 100 gross tons shall have means to make them watertight. Replace the gasket on aft hatch.
46 CFR 171.114(a)(2) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 7 October 2019
Resolution: Received photos clearing this deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 September 2018
Resolved
Replace fire hose with leak with satisfactory fire hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2018
Resolved 24 September 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2018
Resolved
Install blank on port side distribution panel on navigation bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 September 2018
Electrical › Electric Generation Source (emergency) › Ground Detection
Issued 8 November 2017
Resolved
Install ground detection.
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 3 April 2018
Resolution: Recieved information from the operator that the system is ungrounded. Operator installed the proper ground detection.
Engineering › Pressure Vessel › Relief Valve
Issued 8 November 2017
Resolved
Prove air reciever meets ASME and install the correct relief device.
Action required: 705 - Other - as specified
Resolved 18 January 2018
Resolution: Received letter from operator on 14JAN2018 attesting that the air reciever meets ASME.
Engineering › Reduction Gearing/Clutches › Oil Spray
Issued 1 November 2016
Resolved
Both maine engines leak oil from reduction gears. Make permanent proper repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 17 February 2017
Resolution: Permanent repairs were made on the main engines to prevent leaking fron the reduction gear.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 1 November 2016
Resolved
MMSI number must be programmed into radio to function properly.
Due 7 November 2016
Resolved 14 November 2016
Resolution: The vessel's operator sent pcitures of an installed MMSI number on the VHF radio.
Electrical › Electric Supply System (service) › Cable
Issued 1 November 2016
Resolved
Properly seal cable penetrations through bulkheads.
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 14 November 2016
Resolution: The vessel's operator sent pictures of sealed cable penetrations through vessel's bulkheads.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 October 2015
Resolved
CR01 - Properly secure and organize loose wiring under bridge console.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 12 November 2015
Resolution: Organized wiring under the bridge console.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 October 2015
Resolved
CR02 - Properly mount, organize and secure junction box behind PA system with wiring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 12 November 2015
Resolution: Put wiring for PA system in a secure junction box.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 26 October 2015
Resolved
CR03 - Replace expired battery in identified life float light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 12 November 2015
Resolution: Replaced battery in life float light.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 8 November 2010
Resolved
Properly cap off or blank holes on electrical panel on forward end of engineroom.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 8 December 2010
Resolution: Holes on electrical panel properly blanked off.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 November 2010
Resolved
Properly cap or remove dead end wires in life jacket storage area.
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 8 December 2010
Resolution: Dead end wires removed.
Stability › Watertight Integrity › General
Issued 8 November 2010
Resolved
Ensure all watertight door indicator lights at operating station are operable.
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 8 December 2010
Resolution: All watertight door indicator lights are operable.
Documentation › Markings/Placards › Warning Signs
Issued 8 November 2010
Resolved
Properly label watertight door on fwd side of engineroom and watertight hatch aft of engineroom.
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 8 December 2010
Resolution: Watertight doors and hatches properly labeled.
Documentation › Markings/Placards › Warning Signs
Issued 8 November 2010
Resolved
Properly label emergency fuel shutoff on port side of main deck.
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 8 December 2010
Resolution: Emergency fuel shutoff properly labeled.
Stability › Watertight Integrity › Deadlight Cover
Issued 8 November 2010
Resolved
Install washer under dog on port light on port side of galley to ensure proper closure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 8 December 2010
Resolution: Port light properly secured.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 September 2008
Resolved
Secure all loose light fixtures in the aft void (total of 3).
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 26 September 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 22 September 2008
Resolved
Replace one portable fire extinguisher in the aft void IWO the ladder. Fire extinguisher was painted over when the void was painted at the shipyard.
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 26 September 2008
Engineering › Steering Gear System › Rudder Stock
Issued 22 September 2008
Resolved
Arrest leak observed while underway in the starboard side rudder post.
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 26 September 2008
Engineering › Bilge Water Management System › Strainer
Issued 22 September 2008
Resolved
Properly affix strainer on bilge suction pipe in the lazarrette.
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 26 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 September 2008
Resolved
Ensure wire splices IWO of bilge high water alarms are made with proper connectors IAW 46 CFR 183.340(h).
Due 22 October 2008
Resolved 26 September 2008
Engineering › Steering Gear System › Piping
Issued 22 September 2008
Resolved
Properly secure or remove old hydraulic lines no longer in use in the lazarrette.
Action required: 705 - Other - as specified
Due 18 November 2008
Resolved 24 November 2008
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 22 September 2008
Resolved
Provide a captive chain and prove proper closing of the deck hatch for the aft void on the starboard side.
Action required: 705 - Other - as specified
Due 18 November 2008
Resolved 24 November 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 September 2008
Resolved
Secure hanging wire on the port side aft engine compartment IWO the fresh water tank.
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 September 2008
Resolved
Remove dead end wiring on the port side aft engine compartment IWO the fresh water tank
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 26 September 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 22 September 2008
Resolved
Properly mount portable CO2 fire extinguisher aft engine room IWO the starboard generator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2008
Resolved 26 September 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 September 2008
Resolved
Properly secure sampling line for the jacket water discharge temperature gauge from the gauge to the sampling point on the starboard MDE.
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 22 September 2008
Resolved
Repair and properly mount fuel gauge sight glass IWO starboard side header tank for the generator.
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 September 2008
Resolved
Replace cover on the breaker panel in the Water Ballast Tank on the starboard side and ensure all breakers are accurately labeled for service.
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 22 September 2008
Resolved
Remove old air conditioning system and associated piping from the water ballast tank on the starboard side
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 26 September 2008
Construction/Loadline › Structures › Manhole
Issued 22 September 2008
Resolved
Prove proper operation of emergency escape hatch for the engine compartment, aft, starboard side and ensure the hatch is marked as an emergency escape on both sides.
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 September 2008
Resolved
Double clamp all flexible hoses for the keel cooling system to the main engines.
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 22 September 2008
Resolved
Provide tide table and tidal current tables for the area to be transited.
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 22 September 2008
Resolved
Provide a bridge to bridge radio telephony certificate.
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 26 September 2008
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 22 September 2008
Resolved
Provide a current Safety Radio Certificate. Vessel is restricted to 1000 feet from the nearest shore until corrected.
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 26 September 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 September 2008
Resolved
Prove proper operation of vessels stern light prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2008
Resolved 4 November 2008
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 22 September 2008
Resolved
Provide two additional adult life jackets. Vessel restricted to the carriage of 148 passengers until the lifejackets are provided and verified onboard.
Action required: 705 - Other - as specified
Due 18 November 2008
Resolved 24 November 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 September 2008
Resolved
Provide a machinery guard on the forward rotating belt on the port side MDE.
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Stability › Watertight Integrity › Deadlight Cover
Issued 22 September 2008
Resolved
Provide missing dog for portlight in forward stateroom.
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 22 September 2008
Resolved
Provide captive chains for forward, main deck hatches. (2)
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 22 September 2008
Resolved
Provide blanks in open spaces IWO all distribution panels.
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 4 November 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 22 September 2008
Resolved
Properly mount A-II fire extinguisher in vicinity of main deck service space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2008
Resolved 26 September 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 22 September 2008
Resolved
Provide additional A-II portable fire extinguisher in main deck passenger accommodation and properly mount the same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2008
Resolved 26 September 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 22 September 2008
Resolved
Provide A-II portable fire extinguisher on second deck IWO passenger accommodations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2008
Resolved 26 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 September 2008
Resolved
Replace unauthorized non-marine type cable IWO all watertight door indicator switches.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2008
Resolved 4 November 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 September 2008
Resolved
Replace fork type terminal lugs IWO terminal block, aft engine room. (For watertight door indicator switch) with spade or enclosed terminal lugs IAW 46 CFR 183.340(k)
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 4 November 2008
Fire Fighting › Fire Hydrants › Material
Issued 22 September 2008
Resolved
Provide spanner wrench IWO #2 fire hose station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2008
Resolved 26 September 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 September 2008
Resolved
Install emergency lighting in galley and buffet spaces and prove proper operation of the same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2008
Resolved 26 September 2008
Electrical › Electrical Distribution System (service) › Fuse
Issued 22 September 2008
Resolved
Fuse VHF radios at main operating station distribution panel.
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 4 November 2008
Fire Fighting › Fire Pumps › Arrangement
Issued 22 September 2008
Resolved
Provide remote operation of vessel’s fire pump at the operating station IAW 46 CFR 181.300(e)
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 4 November 2008
Engineering › Bilge Water Management System › Valve
Issued 22 September 2008
Resolved
Install screw down valve IWO bilge suction pipe piercing the collision bulkhead. If valve is installed forward of collision bulkhead, means must be provided to operate the valve from the weather deck. If the valve is installed after the collision bulkhead no reach rod is needed; however, the valve must be readily accessible under service conditions. See 46 CFR 182.510(d) for additional details.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2008
Resolved 26 September 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 March 2007
Resolved
Provide paperwork attesting to enrollment in a chemical testing program.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2007
Resolved 22 September 2008
Lifesaving › Lifefloat › Serviceable
Issued 16 March 2007
Resolved
Renew, repair or remove all primary lifesaving on board.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2007
Resolved 22 September 2008
Resolution: All life floats were removed from the vessel. No primary lifesaving remains onboard.
Personnel › Training › Fire Fighting Basic
Issued 16 March 2007
Resolved
Conduct u/w drills with CG inspector
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2007
Resolved 22 September 2008
Engineering › Compressed Air System (start air) › Valve
Issued 16 March 2007
Resolved
Test relief valves on air receivers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2007
Resolved 22 September 2008
Resolution: All air receievers were removed from the vessel.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 16 March 2007
Resolved
Renew vessels radiop station license
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2007
Resolved 22 September 2008
Accommodation/Occupational Safety › Ventilation › General
Issued 16 March 2007
Resolved
Provide means to secure ventilation to engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2007
Resolved 22 September 2008
Navigation › Piloting/Steering › US Coast Pilot
Issued 25 April 2006
Resolved
Provide up to date Eldridge.
Due 2 May 2006
Resolved 1 May 2006
Resolution: Provided sat.
Fire Fighting › Fire Hoses › Material
Issued 25 April 2006
Resolved
Replace missing hose rack at station #3.
Due 2 May 2006
Resolved 1 May 2006
Resolution: Replaced sat.
Lifesaving › Lifebuoys › Serviceable
Issued 25 April 2006
Resolved
Make repairs to all three life rings.
Due 2 May 2006
Resolved 1 May 2006
Resolution: Repaired sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 April 2006
Resolved
repair high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2006
Resolved 1 May 2006
Resolution: Repaired sat.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 25 April 2006
Resolved
Replace lifejacket donning placards.
Due 2 May 2006
Resolved 1 May 2006
Resolution: Replaced sat.
Engineering › Bilge Water Management System › Interface Detector
Issued 11 May 2005
Resolved
Repair or replace the bilge high water level alarm to the aft steering space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 May 2005
Resolved 18 May 2005
Fire Fighting › Firemans Outfit › Axe
Issued 11 May 2005
Resolved
Supply and install brakets for the fire ax.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 May 2005
Resolved 18 May 2005
Lifesaving › Lifebuoys › Serviceable
Issued 11 May 2005
Resolved
Replace the line around the life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2005
Resolved 18 May 2005
Resolution: Replaced entire life ring.
Lifesaving › Buoyant Apparatus › Painter
Issued 11 May 2005
Resolved
Replace the painter lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2005
Resolved 18 May 2005
Lifesaving › Buoyant Apparatus › Serviceable
Issued 11 May 2005
Resolved
Repair in accordance with the manufactures instructions or replace the buoyant apparatus that are cracked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2005
Resolved 18 May 2005
Resolution: Buoyant apparatus repaired in accordance with manufactures instruction.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 11 May 2005
Resolved
Properly tie and stow the life lines on all the buoyant apparatus.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2005
Resolved 18 May 2005
Engineering › Steering Gear System › Rudder Stock
Issued 11 May 2005
Resolved
Repair the excessive leaking on both rudder post.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2005
Resolved 18 May 2005
Engineering › Bilge Water Management System
Issued 4 May 2004
Resolved
Install and prove proper operation of aft steering bilge high water level alarm. LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2004
Resolved 10 May 2004
Resolution: High water level alarm installed and is in opperation.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 4 May 2004
Resolved
Find and repair the leak in the rubber membrane overhead above the bar area. LEGACY COMPONENT DESC: Recreation Space
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2004
Resolved 10 May 2004
Resolution: Leaks in the overhead repaired.
Accommodation/Occupational Safety › Occupational Safety
Issued 4 May 2004
Resolved
Replace the middle rail, starboard side ladder to the pilot house. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2004
Resolved 10 May 2004
Resolution: Middle rail installed on ladder to pilot house.
Engineering › Steering Gear System
Issued 4 May 2004
Resolved
Repair starboard rudder post excessive leaking. LEGACY COMPONENT DESC: Rudder Bearing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2004
Resolved 10 May 2004
Resolution: Packing gland around the starboard rudder post properly adjusted to stop excessive leaking.
Lifesaving › Lifejacket/PFD (General)
Issued 4 May 2004
Resolved
Provide five more adult and two more child lifejackets to meet COI requirments. Vessel shall carry a maximum of 142 passengers until new lifejackets are onboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2004
Resolved 10 May 2004
Resolution: Vessels rep provided 5 more adult and 2 more child life jackets.
Fire Fighting › Fire Main
Issued 26 January 2004
Resolved
Leak in a 90-degree elbow in the fire main piping in the engine room. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 5 February 2004
Resolution: Replaced 90 degree elbow.
Construction/Loadline › Structures
Issued 26 January 2004
Resolved
Swash bulkhead and attached frames in the foscle are rusted through. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 5 February 2004
Resolution: Cut out and welded in new sections of the rusted out swash bulkheads and attached frames.
Engineering › Freshwater System (jacketwater cooling)
Issued 26 January 2004
Resolved
Repair leak in port main engine coolant line IWO inboard keel cooler. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 5 February 2004
Resolution: Tighten loose hose clamps in the main engine coolant line.
Engineering › Fuel Oil Service System
Issued 26 January 2004
Resolved
Repair fuel oil leak in the supply line for the generator. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 20 February 2004
Resolution: Replaced faulty fuel oil cut out valve with a new 3/8" ball valve.
Engineering › Shafting/Propeller Arrangements
Issued 26 January 2004
Resolved
Install cut out valves in the port and starboard shaft stern tubes cooling lines. LEGACY COMPONENT DESC: Stern Tube
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 5 February 2004
Resolution: Installed cut out valves in the shaft cooling lines in the engine room.
Construction/Loadline › Structures
Issued 26 January 2004
Resolved
Cap off the two 1/2" pipe nipple penetrations through the aft bulkhead in the water tank room. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 5 February 2004
Resolution: 1/2" caps installed on bulkhead penetrations.
Engineering › Bilge Water Management System
Issued 26 January 2004
Resolved
Replace missing strainer in aft steering. LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 5 February 2004
Resolution: The bilge strainer has been properly installed in the bilge system.
Accommodation/Occupational Safety › Occupational Safety
Issued 26 January 2004
Resolved
Replace all missing wood screws in the wooden hand railsthroughout the entire vessel. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 5 February 2004
Resolution: Wood screws properly installed in the hand rails throughout the vessel.
Engineering › Sea-water System (primary cooling)
Issued 26 January 2004
Resolved
Before vessel renters the water, inspect sea chest and the three valves in the sea chest. LEGACY COMPONENT DESC: Sea Chest
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 5 February 2004
Resolution: Sea chest and all valves inspected on 5 Feb 05.
Engineering › Steering Gear System
Issued 22 April 2003
Resolved
Replace hydraulic ram steering hoses.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 April 2003
Resolved 29 April 2003
Engineering › Thrusters
Issued 22 April 2003
Resolved
Renew hydraulic flexible line to bow thruster.
Action required: 705 - Other - as specified
Due 22 April 2003
Resolved 22 April 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 22 April 2003
Resolved
Remove cooking hot plates in the galley.
Action required: 705 - Other - as specified
Due 29 April 2003
Resolved 29 April 2003
Construction/Loadline › Penetrations
Issued 22 April 2003
Resolved
Repair drain line for sink in forward galley.
Action required: 705 - Other - as specified
Due 29 April 2003
Resolved 29 April 2003
Communications › Radio Communications
Issued 22 April 2002
Resolved
Provide a copy of FCC operators permit.
Condition: Unknown
Due 3 May 2002
Resolved 3 May 2002
Resolution: Provided copy of the application.
Lifesaving
Issued 22 April 2002
Resolved
Replace all deteroriated lines on the Life Floats.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2002
Resolution: All life lines properly replaced.
Lifesaving › Lifejacket/PFD (Type III)
Issued 22 April 2002
Resolved
Limited to carrying 138 adults and 12 children until replacement of failed life jackets. LEGACY COMPONENT DESC: Quantity
Due 3 May 2002
Resolved 3 May 2002
Resolution: Provided 24 adult and 4 childrens life jackets.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 22 April 2002
Resolved
Properly repair the cooling water leak on the port main disel engine.
Due 3 May 2002
Resolved 3 May 2002
Resolution: Replaced the radiator cap. Operationally test engine, no leaks.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 22 April 2002
Resolved
Repair the fuel leak on the starboard generator piping along inboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2002
Resolution: Replaced all of the faulty fuel hoses.
Engineering › Fuel Oil Storage/Transfer System
Issued 22 April 2002
Resolved
Replace the broken sight glass on the starboard fuel oil storage tank. LEGACY COMPONENT DESC: Tank
Condition: Unknown
Due 3 May 2002
Resolved 3 May 2002
Resolution: Installed new sight glass on the starboard fuel tank.
Engineering › Bilge Water Management System
Issued 22 April 2002
Resolved
Replace the bilge strainer in the void space aft of the engine room. LEGACY COMPONENT DESC: Strainer
Condition: Unknown
Due 3 May 2002
Resolved 3 May 2002
Resolution: Installed new bilge strainer.
Engineering › Bilge Water Management System
Issued 22 April 2002
Resolved
Clear the forepeak bilge strainer of debris. LEGACY COMPONENT DESC: Strainer
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2002
Resolution: Cleaned out the bilge in the forepeak.
Fire Fighting › Fire Pumps
Issued 22 April 2002
Resolved
Replace the pressure guage to the #1 fire pump.
Due 3 May 2002
Resolved 3 May 2002
Resolution: Installed new pressure guage.
Fire Fighting › Fire Pumps
Issued 22 April 2002
Resolved
Properly repair the engine room suction line to the fire pumps. LEGACY COMPONENT DESC: Suction Valve
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2002
Resolution: Installed new pipinf in the fire main system. Operationally tested the pump, test sat.
Stability › Watertight Integrity
Issued 20 November 2001
Resolved
Properly repair the wasted knife edge and provide gasket on aft hold (liquor locker) hatch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2001
Stability › Watertight Integrity
Issued 20 November 2001
Resolved
Properly repair the port and starboard port holes in the galley (gasket and dogs).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Resolution: 6 portlights (3 port and 3 stbd) were regasketed and all dogs repaired and made operable.
Construction/Loadline › Hull
Issued 20 November 2001
Resolved
Made repairs to 5 areas of hull plating. See narrative summary for details. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 December 2001
Resolution: Cropped and renewed 5 areas of hull plating. Conducted water hose pressure test. See Narrative summary for details.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 November 2001
Resolved
Properly repair the handrail starboard side forward at the steps.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2001
Engineering › Bilge Water Management System › Piping
Issued 20 November 2001
Resolved
Crop and renew deteriorated bilge pipe under water tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2001
Resolution: New piping, 1 1/2" X 6'', installed from forward bulkhead back.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 20 November 2001
Resolved
Port prop had bend on one blade tip.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 14 December 2001
Resolution: Had port prop sent out for reconditioning.
Lifesaving
Issued 8 May 2001
Resolved
Provide a PA system as required by 46 CFR 184.610
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Navigation
Issued 8 May 2001
Resolved
Properly tighten the packing for the starboard rudderpost
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Lifesaving
Issued 8 May 2001
Resolved
Prior to carrying passengers, provide a current certificate of documentation sticker
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Construction/Loadline
Issued 8 May 2001
Resolved
Prove operation of the WTD light for the forward engine room door
Condition: Unknown
Due 25 May 2001
Resolved 22 April 2002
Engineering
Issued 8 May 2001
Resolved
Properly tighten the packing for the starboard propeller shaft
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Documentation
Issued 8 May 2001
Resolved
) Prior to carrying passengers, provide a current certificate of documentation sticker
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Electrical
Issued 8 May 2001
Resolved
Provide a cover for the electrical capacitor for the air compressor
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Electrical
Issued 31 May 2000
Resolved
REPLACE COVERS ON FLOURECSENT LIGHT FIXTURES IN ENGINEROOM.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Electrical
Issued 31 May 2000
Resolved
PROVIDE GUARD FOR LIGHT FIXTURE IN REFER.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Electrical
Issued 31 May 2000
Resolved
PROVIDE GLOBE FOR LIGHT FIXTURE IN ENGINE ROOM.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Construction/Loadline
Issued 31 May 2000
Resolved
REPAIR EMERGENCY ESCAPE SCUTTLE IN ENGINE ROOM.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Construction/Loadline
Issued 31 May 2000
Resolved
RELABEL ALL WTD'S TO READ, "MUST BE KEPT CLOSED AT ALL TIMES WHILE UNDERWAY".
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Lifesaving
Issued 31 May 2000
Resolved
PASSENGER CARRYING CAPACITY REDUCED TO 101 UNTIL 48 ADULT LIFEJACKETS ARE REPAIRED/REPLACED.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Electrical
Issued 31 May 2000
Resolved
REPAIR BREAKER BOX ON STBD BULKHEAD IN ENGINEROOM.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Engineering
Issued 31 May 2000
Resolved
REPLACE MACHINERY GUARDS ON BOTH MDE'S.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Engineering
Issued 31 May 2000
Resolved
REPAIR OIL LEAK ON STBD MDE.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Electrical
Issued 31 May 2000
Resolved
REPAIR EMERGENCY LIGHTING IN ENGINEROOM.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Fire Fighting
Issued 31 May 2000
Resolved
PROVIDE SPANNER WRENCH FOR HOSE STATION IN ENGINEROOM.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Electrical
Issued 31 May 2000
Resolved
REPAIR JUNCTION BOXES ABOVE BOTH MDE'S.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Construction/Loadline
Issued 31 May 2000
Resolved
ADJUST WTD IN ENGINEROOM TO OPEN AND CLOSE PROPERLY.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Lifesaving
Issued 31 May 2000
Resolved
RECONFIGURE PASSENGER RESTRICTION CHAINS ON STBD WHEELHOUSE ENTRY.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Lifesaving
Issued 31 May 2000
Resolved
REPLACE LIFERING ON STBD BRIDGE WING.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Construction/Loadline
Issued 31 May 2000
Resolved
REPAIR OPEN/CLOSE INDICATOR LIGHT FOR GALLEY WTD.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Construction/Loadline
Issued 31 May 2000
Resolved
REPAIR GALLEY WTD AND APPLY PROPER OPEN/CLOSE DIRECTIONS.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Electrical
Issued 31 May 2000
Resolved
REPAIR AND REMOUNT ELECTRICAL BOX IN VOID #1.
Condition: Unknown
Due 8 June 2000
Resolved 13 June 2000
Construction/Loadline
Issued 23 November 1999
Resolved
REMOVE RUST SCALE DEBRIS IN WAY OF FORE-PEAK BILGE SUCTION STRAINER.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 23 November 1999
Resolved
INSTALL BILGE HIGH LEVEL ALARMS IN ENGINE ROOM, RUDDER ROOM AND GALLEY.
Condition: Unknown
Due 6 December 1999
Resolved 30 December 1999
Construction/Loadline
Issued 23 November 1999
Resolved
CROP AND RENEW WASTED BILGE LINES IN RUDDER AND ENGINE ROOM.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 23 November 1999
Resolved
RENEW THROUGH HULL FITTING IN GALLEY.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 23 November 1999
Resolved
RENEW BILGE SUCTION STRAINER IN AFTER LAZARETTE.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Engineering
Issued 23 November 1999
Resolved
RENEW PORT SIDE PROPELLER.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 23 November 1999
Resolved
RENEW BILGE OVER BOARD DISCHARGE VALVE IN ENGINE ROOM. (GUIDES ON BOTH SIDES OF GATE VALVE BROKEN OFF)
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Documentation
Issued 16 April 1999
Resolved
PROVIDE PROOF OF CURRENT AND VALID CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Lifesaving
Issued 16 April 1999
Resolved
PROPERLY STENCIL NAME OF VESSEL ON LIFE FLOAT PADDLES.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Engineering
Issued 16 April 1999
Resolved
PROVIDE LAGGING ON STBD MAIN ENGINE EXHAUST LINE.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Electrical
Issued 16 April 1999
Resolved
REMOVE DEAD END WIRING FROM CABIN TOP, STBD SIDE, AFT OF PILOT HOUSE.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Lifesaving
Issued 16 April 1999
Resolved
VESSEL SHORT 2 ADULT PFD. TOTAL PERSONS ALLOWED ON BOARD REDUCED BY 2 UNTILDEFICIENCY HAS BEEN CORRECTED.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Documentation
Issued 16 April 1999
Resolved
PROVIDE PROOF OF VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 16 April 1999
Resolved 20 April 1999
Construction/Loadline
Issued 4 June 1998
Resolved
Make repairs to hole in bulkhead main deck port side aft of door to engine room.
Condition: Unknown
Due 26 June 1998
Resolved 13 July 1998
Construction/Loadline
Issued 4 June 1998
Resolved
Make permanent repairs to water fill pipe port side, lube oil vent pipe port side and water tank vent pipe stbd side.
Condition: Unknown
Due 26 June 1998
Resolved 13 July 1998
Electrical
Issued 4 June 1998
Resolved
Remove dead end wire 01 deck stbd side.
Condition: Unknown
Due 26 June 1998
Resolved 13 July 1998
Electrical
Issued 4 June 1998
Resolved
properly support 220 cable to stove. Cable located in void aft of chain locker.
Condition: Unknown
Due 26 June 1998
Resolved 13 July 1998
Documentation
Issued 4 June 1998
Resolved
Post community hot line number.
Condition: Unknown
Due 26 June 1998
Resolved 13 July 1998
Lifesaving
Issued 4 June 1998
Resolved
Total of persons limited to 170 until 9 failed adult and 1 failed child life jackets replaced.
Condition: Unknown
Due 26 June 1998
Resolved 20 July 1998
Documentation
Issued 4 June 1998
Resolved
Route limited to 1000 feet from shore until valid FCC Radiotelephony certificate aboard.
Condition: Unknown
Due 9 June 1998
Resolved 23 June 1998
Navigation
Issued 4 June 1998
Resolved
Provide proof of compass deviation card.
Condition: Unknown
Due 10 June 1998
Resolved 23 June 1998
Construction/Loadline
Issued 4 June 1998
Resolved
prove bilge pump suction of paint locker/void space.
Condition: Unknown
Due 26 June 1998
Resolved 13 July 1998
Documentation
Issued 4 June 1998
Resolved
Provide information for drug testing program, proof of testing, collection site, MRO and lab.
Condition: Unknown
Due 26 June 1998
Resolved 13 July 1998
Construction/Loadline
Issued 19 November 1997
Resolved
CROP AND RENEW TO GOOD STEEL THE WASTED AREA UNDER THE PORT SIDE GALLEY WINDOWS WHERE THE GALLEY DECK MEETS THE SIDE SHELL.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Accommodation/Occupational Safety
Issued 19 November 1997
Resolved
PROVE PROPER OPERATION OF WATERTIGHT ESCAPE HATCHES LOCATED IN THE E/R, SCULLERY AND REEFER BOX.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Construction/Loadline
Issued 19 November 1997
Resolved
RENEW THE SECURING BOLTS AND PROVE ADEQUACY OF THE SEWAGE TANK ACCESS PLATE.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Construction/Loadline
Issued 19 November 1997
Resolved
CROP AND RENEW TO GOOD STEEL THE APPROXIMATELY 3'X 5' WASTED SECTION OF BOTTOM PLATE JUST FORWARD OF THE PORT SHAFT STRUT.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Documentation
Issued 19 November 1997
Resolved
PROVIDE A COMPLETE COPY OF THE AUDIO GAUGING REPORT AS SUBMITTED BY GLOUCESTER MARINE RAILWAYS.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Lifesaving
Issued 13 May 1997
Resolved
MOVE ALL FLAMMABLES THAT ARE LOCATED THROUGHOUT THE VESSEL TO THE PAINT LOCKER.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Electrical
Issued 13 May 1997
Resolved
PLACE BLANK BREAKERS IN THE E/R MAIN ELECTRICAL DISTRIBUTION PANEL WHERE MISSING.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Documentation
Issued 13 May 1997
Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE CHEMICAL TESTING REGULATIONS CONTAINEDIN 46 CFR PART 16.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Navigation
Issued 13 May 1997
Resolved
RENEW AS ORIGINAL THE VHF-FM ANTENNA.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Accommodation/Occupational Safety
Issued 13 May 1997
Resolved
RENEW THE BROKEN STEPS AND HAND RAIL LEADING TO THE LIFE FLOAT STORAGE DECK.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Electrical
Issued 13 May 1997
Resolved
PLACE APPROPRIATE LIGHT BULBS IN ALL VACANT SOCKETS OF THE PARADE STRING OFLIGHTS.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Lifesaving
Issued 13 May 1997
Resolved
CONDUCT EMERGENCY DRILLS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Lifesaving
Issued 13 May 1997
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, RENEW THE RETROREFLECTIVE MATERIAL ON THE 6 ADULT AND 6 CHILD LIFE JACKETS AS DISCUSSED AND IDENTIFIED.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Construction/Loadline
Issued 13 May 1997
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROPERLY INSTALL GASKET AND HATCH COVERS OVER THE CHAIN LOCKER AND BALLAST TANK COMPARTMENTS.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Construction/Loadline
Issued 13 May 1997
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVE WATERTIGHTNESS OF THE 4 AIRPORTSLOCATED IN THE GALLEY.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Fire Fighting
Issued 15 April 1996
Resolved
PROVIDE PROPER BRACKET AND IDENTIFICATION SIGN FOR FIRE EXTINGUISHER STOREDIN CLOSET ON UPPER DECK.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Construction/Loadline
Issued 15 April 1996
Resolved
PROVIDE CLOSURES FOR GALLEY AND DISHWASHER SPACE PORT HOLES.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Navigation
Issued 15 April 1996
Resolved
REPAIR LEAKING SEAL IN STARBOARD STEERING SYSTEM HYDRAULIC ACTUATOR.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Lifesaving
Issued 15 April 1996
Resolved
INSTALL RETRO-REFLECTIVE TAPE ON ALL RING BUOYS.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Electrical
Issued 15 April 1996
Resolved
PROPERLY SEAL UNUSED MAIN DECK ELECTRICAL PENETRATION.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Lifesaving
Issued 15 April 1996
Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE DRUG TESTING REQUIREMENTS OF 46 CFR PART 16.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Construction/Loadline
Issued 28 April 1995
Resolved
PRIOR TO OPERATION, AND NO LATER THAN 28 APRIL, 1995, DEWATER AND MAKE AVAILABLE FOR INSPECTION RUDDER COMPARTMENT.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Fire Fighting
Issued 28 April 1995
Resolved
PRIOR TO OPERATION, AND NO LATER THAN 28 APRIL, 1995, CONDUCT UNDERWAY DRILLS TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Lifesaving
Issued 28 April 1995
Resolved
PRIOR TO OPERATION AND NO LATER THAN 28 APR 95, LASH ALL OARS TO THEIR RESPECTIVE LIFEFLOATS.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Fire Fighting
Issued 28 April 1995
Resolved
PRIOR TO OPERATION, AND NO LATER THAN 28 APRIL, 1995, RELOCATE FIRE AXE IN ACCORDANCE WITH 46 CFR 181.35.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Lifesaving
Issued 28 April 1995
Resolved
PRIOR TO OPERATION, AND NO LATER THAN 28 APRIL, 1995, RENEW WATER LIGHT BATTERY FOR RING BUOY PORT SIDE.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Lifesaving
Issued 28 April 1995
Resolved
PROVIDE 30 ADDITIONAL COAST GUARD APPROVED ADULT TYPE I LIFEPRESERVERS AND STENCILE VESSEL NAME ON EACH, PRIOR TO OPERATION AND NO LATER THAN 28 APRIL, 1995.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Fire Fighting
Issued 28 April 1995
Resolved
PROPERLY LABEL FIRE STATIONS ON BOARD, NO LATER THAN 15 MAY, 1995.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Fire Fighting
Issued 28 April 1995
Resolved
REMOVE FROM VESSEL, OR HAVE FIXED AND SERVICED BI CO2 HAND PORTABLE EXTINGUISHER IN ENGINE ROOM.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Lifesaving
Issued 28 April 1995
Resolved
PRIOR TO OPERATION, AND NO LATER THAN 28 APRIL, 1995, REPLACE RING BUOY ON STARBOARD SIDE OF VESSEL.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Fire Fighting
Issued 28 April 1995
Resolved
PRIOR TO OPERATION, AND NO LATER THAN 28 APRIL, 1995, REMOVE FROM VESSEL PLASTIC SUICIDE NOZZLE AND REPLACE WITH BRONZE OR EQUIVALENT MATERIAL.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Fire Fighting
Issued 28 April 1995
Resolved
REPLACE BOTH FIRE PUMP DISCHARGE PRESSURE GAUGES NO LATER THAN 15 MAY, 1995.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Lifesaving
Issued 28 April 1995
Resolved
PROVIDE 3 ADDITIONAL COAST GUARD APPROVED CHILD TYPE I LIFEPRESERVER AND STENCILE VESSEL NAME ON EACH, PRIOR TO OPERATION AND NO LATER THAN 28 APRIL, 1995.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Navigation
Issued 28 April 1995
Resolved
PROVE PROPER OPERATION OF STERN NAVIGATIONAL LIGHT, PRIOR TO OPERATION AND NO LATER THAN 28 APRIL, 1995.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Engineering
Issued 14 April 1994
Resolved
PROVE PROPER OPERATION OF OIL PRESSURE AND WATER TEMPERATURE GAUGES FOR BOTH MAIN ENGINES AT OPERATORS STATION AS PER 46 CFR 182.20-5(B).
Condition: Unknown
Due 14 April 1994
Resolved 29 April 1994
Electrical
Issued 14 April 1994
Resolved
PROVIDE AND INSTALL NON-CONDUCTIVE MATTING IN FRONT OF MAIN 120/208 VOLT PANEL.
Condition: Unknown
Due 14 April 1994
Resolved 29 April 1994
Documentation
Issued 14 April 1994
Resolved
MAKE RANDOM DRUG TESTING FILE/RESULTS AVAILABLE FOR REVIEW.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Electrical
Issued 14 April 1994
Resolved
PROVE PROPER OPERATION OF PORT DIESEL GENERATOR SET UNDERLOAD.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Engineering
Issued 14 April 1994
Resolved
PROVE PROPER OPERATION OF STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Engineering
Issued 14 April 1994
Resolved
PROVE PROPER OPERATION OF MAIN ENGINE EMERGENCY STOPS.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Electrical
Issued 14 April 1994
Resolved
PROVE PROPER OPERATION OF BOTH GENERATORS VOLT METERS AND AMP METERS IN MAIN PANEL BOARD IN ENGINE ROOM AS PER 46 CFR 185.10-5(G).
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Fire Fighting
Issued 14 April 1994
Resolved
REINSTALL BRACKET TO HANG FIRE HOSE PORT SIDE EXTERIOR OF PILOT HOUSE.
Condition: Unknown
Due 14 April 1994
Resolved 29 April 1994
Construction/Loadline
Issued 12 November 1993
Resolved
CROP AND RENEW 220SQFT OF 5/16" BOTTOM PLATE DUE TO WASTAGE.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993
Construction/Loadline
Issued 12 November 1993
Resolved
REPAIR/RENEW ALL BILGE LINE STRAINERS WHERE MISSING/WASTED NO LATER THAN 17NOV93.
Condition: Unknown
Due 12 November 1993
Resolved 12 November 1993
Construction/Loadline
Issued 12 November 1993
Resolved
CROP AND RENEW 10SQFT OF SIDE PLATE DUE TO WASTAGE.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993
Construction/Loadline
Issued 12 November 1993
Resolved
PROVIDE A COPY OF THE MOST RECENT GUAGING REPORT TO [name withheld] NO LATER THAN 12DEC93.
Condition: Unknown
Due 12 November 1993
Resolved 12 November 1993
Engineering
Issued 7 September 1993
Resolved
PRIOR TO CARRYING PASSENGERS PROVE PROPER OPERATION OF BOTH PROPULSION SHAFTS/PROPELLERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 September 1993
Resolved 7 September 1993
Fire Fighting
Issued 7 May 1993
Resolved
INSTALL THIRD FIRE STATION AS PER 46 CFR 181.15-5(A) AND 46 CFR 181.15-10 (A) & (C) ON 01 DECK IN VICINITY OF BAR AREA AND NOT LATER THAN 07 JULY 1993.
Condition: Unknown
Due 7 May 1993
Resolved 7 May 1993
Navigation
Issued 23 April 1993
Resolved
ON OR BEFORE NEXT REGULARLY SCHEDULED DRYDOCKING OPEN FOR INSPECTION BY COAST GUARD MARINE INSPECTOR STRUCTURAL SUPPORTS ON BOTH PORT & STARBOARD RUDDER POSTS IN STEERING COMPARTMENT.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Fire Fighting
Issued 23 April 1993
Resolved
PRIOR TO CARRYING PASSENGERS THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS.
Condition: Unknown
Due 14 May 1993
Resolved 14 May 1993
Fire Fighting
Issued 23 April 1993
Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 May 1993
Resolved 14 May 1993
Electrical
Issued 28 April 1992
Resolved
COMPLETE INSTALLATION OF NEW NORTHERN LIGHT 60 KW GENERATOR AND PRIOR TO OPERATION CONDUCT A TEST UNDER LOAD IN THE PRESENCE OF A COAST GUARD MARINE INSPECTIOR.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Construction/Loadline
Issued 17 May 1990
Resolved
THE CONCRETE LOCATED IN THE ENGINEROOM BILGE AT THE AFT BULKHEAD SHALL BE REMOVED AND THE BOTTOM PLATE MADE AVAILABLE FOR A COAST GUARD INSPECTION PRIOR TO BEING PAINTED.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Construction/Loadline
Issued 17 May 1990
Resolved
DUE TO UNAUTHORIZED/UNAPPROVED STRUCTURAL MODIFICATIONS, VSL IS TO COMPLY WITH 46 CFR 69.01-15 AND BE READMEASURED. IN LIEU THEREOF, THE REMOVED AND/OR MODIFIED BULKHEADS SHALL BE RETURNED TO THE CONDITION AS NOTED ON THE U.S.C.G.-APPROVED DRAWINGS, AND MADE READY FOR A COAST GUARD INSPECTION.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Construction/Loadline
Issued 24 October 1989
Resolved
OVERBOARDS PENETRATE HULL LESS THAN SIX INCHES ABOVE THE SUBDIVISION LOAD- LINE. OVERBOARDS DO NOT HAVE POSITIVE ACTION VALVES LOCATED AS CLOSE AS POSSIBLE TO THE HULL TO PREVENT WATER FROM ENTERING THE VESSEL IF THE PIPE FRACTURES OR OTHERWISE FAILS. BRING INTO COMPLIANCE WITH 46CFR 171.119.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Construction/Loadline
Issued 24 October 1989
Resolved
NONMETALLIC PIPE PENETRATING WATER TIGHT BULKHEADS NOT IN COMPLIANCE WITH 46CFR 182.40. REMOVE PVC, REPLACE WITH METALLIC PIPE OR BRING EXISTING SYSTEM INTO COMPLIANCE WITH 46CFR 182.40.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Engineering
Issued 5 November 1987
Resolved
INSTALL OIL TIGHT BULKHEAD IN PORT AND STARBOARD WING FUEL OIL TANKS IN WAYOF FRAME #23 AS REQUIRED BY THE MARINE SAFETY CENTER.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Construction/Loadline
Issued 5 November 1987
Resolved
INSTALL AND PROVE OPERATION OF WATERTIGHT DOOR INDICATOR PANEL.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987