MITSUI OCEAN FUJI is a 2009 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2010, most recently in July 2026, along with 31 deficiencies and 1 operational control.
Records from 2010 to 2026. Most recent: inspection, 17 July 2026.
- Built
- 2009
- Last inspected
- 17 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 31 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9417086 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6XC6
940685
Flag
BAHAMAS, THE
—
Maury page id
psix-940685
Inspections, by type
…with no type recorded2
Years with a record
12 calendar years (2010–2026)
The 35 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it18873 - Displacement, Ton
10657 - Convention (Subpart B), Net Ton
32477 - Convention (Subpart B), Gross Ton
3000 - Dead Weight, Ton
10657 - Convention (Subpart B), Net Ton
32477 - Convention (Subpart B), Gross Ton
3000 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 35
17 July 2026
VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8443874
30 March 2025
PSC B · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8098757
8 January 2025
VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8059835
9 May 2024
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7910189
5 May 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7924159
2 May 2024
COC-CVE Annual · PSC A
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7903662
21 February 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7878074
6 February 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7877270
5 December 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7842563
15 October 2023
COC-CVE Quarterly · PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7807728
7 July 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7833433
14 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7796043
19 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7738843
15 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7739605
30 April 2023
COC-CVE Annual · PSC A
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7677108
28 February 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7643550
4 January 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7616444
30 November 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7602172
13 October 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7577056
24 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542940
9 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7529430
29 April 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7440676
25 April 2022
PSC B · COC-CVE Initial · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7436053
25 April 2022
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7437356
8 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6937090
30 October 2017
COC-CVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6294739
19 December 2016
COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6049284
5 January 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5791066
18 December 2015
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5784463
3 December 2015
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5774819
28 October 2015
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5748951
5 January 2012
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4216484
20 December 2011
COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4208010
19 December 2010
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3910968
5 January 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3659445
Deficiency record · 31
01 - Certificates & Documentation › 012 - Crew Certificates › Cert for personnel on survival craft & rescue boat
Issued 30 March 2025
Resolved
The level of knowledge of the subjects listed in column two of table A-VI/2-1 shall be sufficient to enable the candidate to launch and take charge of a survival craft or rescue boat in emergency situations. Port side life raft launching crew were unable to demonstrate adequate launching of liferaft without significant on-scene training and assistance of Safety Officer.
STCW 2017 A-VI/2.2
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 30 March 2025
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Port side life raft davit brake is not operational.
74 SOLAS 20 III/16.3
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 March 2025
Resolved
The fire integrity of the divisions shall be maintained at openings and penetrations. 02 Emergency escape hatches leading out of the engine room were locked in the open position.
74 SOLAS 04 II-2/9.1.3
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 March 2025
Resolved
The fire integrity of the divisions shall be maintained at openings and penetrations. 06 Fire Screen doors throughout the vessel were not closing fully.
74 SOLAS 20 II-2/9.1.3
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 March 2025
Resolved
The function of fixed fire detection and fire alarm systems shall be tested to the satisfaction of the administration by means of equipment producing hot air at the appropriate temperature. Ships crew ran out of cartridges to conduct heat detection tests in the galley for heat detectors. Deck 8 galley heat detection could not be tested.
74 SOLAS 04 II-2/7.2.4.2
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 30 March 2025
Resolved
The company should ensure that the safety and environmental-protection policy is implemented and maintained at all levels of the organization, both ship-based and shore-based. Throughout the entirety of the exam, several ISM related concerns were identified. These issues are highlighted in deficiencies 01, 02, and 03. An ISM audit is required to resolve this deficiency.
74 SOLAS 20 IX/3.1
ISM Code A 2.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 March 2025
Resolved
Sauna electrically heated ovens shall be provide with a timer. Sauna did not have a timer.
74 SOLAS 04 II-2/9.2.2.3.4.6
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 2 May 2024
Resolved
An International Load Line Certificate shall be issued to every ship which has been surveyed and marked in accordance with the present Convention. Vessel's deck line is painted the same color as the hull.
Load Line Convention Article 16(1)
50a
Code 01108
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 May 2024
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5° opposing closure. Roller shutter 3.3.19 between crew galley and crew mess did not close via automatic or by manual means.
74 SOLAS 20 II-2/9.4.1.1.5.1
10c
Code 07105
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 2 May 2024
Resolved
Each liferaft or group of liferafts shall be stowed with a float-free arrangement so that each floats free and, if inflatable, inflates automatically when the ship sinks. Starboard side life raft was found connected to the vessel and not to the float-free arrangement.
74 SOLAS 20 III/13.4.2
10c
Code 11110
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 2 May 2024
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Starboard side life raft crew was not familiar with the life raft and which line was the painter line and which lines were the bowsing lines.
74 SOLAS 20 III/19.2.1
10c
Code 04110
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 April 2023
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Forward boiler section valve in the high pressure water mist system failed and was not working as designed.
74 SOLAS (20)II-2/14.1.1
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 30 April 2023
Resolved
Except for hatches between cargo, special category, store, and baggage space, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. Fire Screen Door number 4.3.38 is a double leaf door which overlaps after closing due to ineffective sequencing bar.
74 SOLAS 09 II-2/9.4.1.1.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 April 2023
Resolved
Except for hatches between cargo, special category, store, and baggage space, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. Fire Screen Door numbers 1.2.2, 1.2.1, and 3.3.34 did not latch completely.
74 SOLAS 09 II-2/9.4.1.1.1
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 30 April 2023
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. While testing the starboard side life raft davit, the raft onload release handle was caught under the raft cradle, causing the liferaft to release from the hook.
74 SOLAS 20 III/19.2.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 April 2022
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation an control. STBD Main propulsion engine does not operate at full capacity.
74 SOLAS (20)II-1/31
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 April 2022
Resolved
Means of escape from control stations, accommodation spaces and service spaces shall be maintained in a safe condition, clear of obstacles. Multiple stairway landings in way of muster stations had signs obstructing passage.
74 SOLAS (20) II-2/13.1.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 April 2022
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resistant divisions, and protection of openings in these divisions. The following fire screen doors required adjustment.
FSD 7.4.47, 7.5.34, and 9.5.44.
74 SOLAS (20) II-2/14.2.1.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2022
Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Combustible trash was not stowed in a non-combustible receptacle in the Main Laundry Space.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 19 December 2016
Resolved
The storage room in the spa (a. Cat. 7) on deck 9 has mnore than daily use amount of flammable material stored in space. There is approximately one month's amount of flammable material currently stored in the space, per information provided by the crew. - 74Solas(14) CH II-2/Reg 9.2.2.3.2.2
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 28 October 2015
Resolved
0750: Fixed fire extinguishing stsytems shall be installed usting dueregard to the fire growth potential of the protected spaces. Compression coupling fixed to cabin 4.2.3 hi-fog piping section valve 512 found parted and water escaping from system. 74 SOLAS (04 Cons.) II-2/10.1.1
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 28 October 2015
Resolved
0399: Safe escape routes shall be provided. Office in main galley found with less than 30%communication opening and means of immediate and clear notification of a fire in the surrounding space. in lieu of adirect access to an acceptiable means of escape. staffs office at rear of main galley. 74 SOLAS (04 Cons.) II-2/13.1.1
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 20 December 2011
Resolved
1270-Fire doors shall be self-closing and be capable of closing w/an angle inclination of up to 3.5 degrees opposing closure. Fire door in laundry (3.1.10) does not function to self close. Also deck 9 pantry has magnetic holdback and is A-0 boundry w/wooden door.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 20 December 2011
Resolved
1270-"B" class divisions are so constructed as to be capable of preventing the passage of flame to the end of the 1st 1/2 hr. of the standard fire test. "B" class doors on I-95 ceck 3 midship loading corridor has damage affecting integrity. 74SOLAS 09 cons. CH II-2 reg 3.4.3
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 20 December 2011
Resolved
0710-Waste receptacles shall be constructed of non-combustible materials. Plastic trash cans w/ flammable waste found in crew lounge and galley on deck 9 aft. 74SOLAS 09 Cons. CH II-2 Reg 4.4.2.
Fire Fighting › Means of Escape › Corridors
Issued 20 December 2011
Resolved
0960-Safe routes shall be provided. Cruise director offices on deck 5 provide no means of escape without leading through lobby space w/printer. 74SOLAS 09 Cons CH II-2 Reg 13.1.1
Fire Fighting › Structural - B Class Divisions › Cabin Doors
Issued 20 December 2011
Resolved
2025- Cabin doors in B class divisions shall be of self-closing type. Hold back hooks are not permitted. Each abandon ship drill shall include a monck search and rescue of passengers trapped in their staterooms during abandon ship drill. Passenger stateroom doors were kept open by deadbolts. Cabin stewards additionally did not have ready access to staterooms in the case that they were doublelocked
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 20 December 2011
Resolved
0750-for determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in categories 1-14. Category 3 space (corridor on deck 3) and category 10 space (A/C and lift machinery rooms) on deck 11 had lockers containing combustible materials. 74 SOLAS 09 Cons CH II-2 reg 9.2.2.3.2
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 19 December 2010
Resolved
0750- Fire prevention- Cabin doors in "B" class divisions shall be of self closing type. Hold back hooks are not permitted. All passenger corridor cabin doors held open with wedges. SOLAS 2009 CH II-2 REG 9.4.1.2.2
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 December 2010
Resolved
0710- Fire Prevention-The approximate time for Hinged Fire door closures shall close be no more than 40s and no less than 10s from the begininning of movement with the ship in an upright position. SOLAS 74 (2009) II-2 Reg 9 4.1.1.4.2
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 19 December 2010
Resolved
0660- Lifejackets -Stowage locations for life saving equipment shall be marked with symbols indicating the devices stowed in that location for the purpose. Large passenger cabins found without lifejacket symbols indicating were lifejackets were stowed. SOLAS 74 (2009) III Reg 20 10