Records from 2008 to 2019. Most recent: inspection, 1 November 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 November 2019
No resolution recorded
Port side transom planking is rotten on ends. Construction of vessel must give consideration for a seaworthy hull. Submit repair proposal in accordance with vessel's original approved plans to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 November 2019
No resolution recorded
Starboard side transom planking is rotten on ends. Construction of vessel must give consideration for a seaworthy hull. Submit repair proposal in accordance with vessel's original approved plans to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 November 2019
No resolution recorded
Rotten wood on port side lazarette 4’ from transom where stanchion penetrates the deck. Submit repair proposal in accordance with vessel's original approved plans to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 1 November 2019
No resolution recorded
Rotten wood main deck port side lazarette 6’ from transom where ventilation piping penetrates the deck. Submit repair proposal in accordance with vessel's original approved plans to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 November 2019
No resolution recorded
Starboard side lazarette 3’ aft from forward bulkhead bottom sheet of plywood has rotten spots. Submit repair proposal in accordance with vessel's original approved
plans to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 1 November 2019
No resolution recorded
Bottom 2 boards centerline transom planking are rotten. Submit repair proposal in accordance with vessel's original approved plans to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 November 2019
No resolution recorded
Forepeak, port side, side-frame 7 rotten at the top.Submit repair proposal in accordance with vessel's original approved plans to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 1 November 2019
No resolution recorded
Forepeak collision bulkhead bottom centerline boards 2 and 3 are rotten. Submit repair proposal in accordance with vessel's original approved plans to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 November 2019
No resolution recorded
Bow thruster space port frames 2 and 3 are rotten at the top. Submit repair proposal in accordance with vessel's original approved plans to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 November 2019
No resolution recorded
Bow thruster space deck over port frames 1 and 2 are rotten. Submit repair proposal in accordance with vessel's original approved plans to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 1 November 2019
No resolution recorded
Starboard side exhaust discharge FRP overlay is separated from wood hull. Submit repair proposal in accordance with vessel's original approved plans to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 1 November 2019
No resolution recorded
Found damage control plug in starboard side chine in compartment 3. Replacement, repair, or refastening of hull planking, plating, and structural members require approval of the cognizant OCMI and notification if made during an emergency.Submit repair proposal in accordance with vessel's original approved plans to CGMI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 November 2019
No resolution recorded
Pre-engineered fire suppression system in engine room was not capable of manual actuation from outside the space, as required. Install in accordance with manufacturer’s instructions and provide servicing report.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 1 November 2019
No resolution recorded
Vessel’s three lifefloats show cracking and deterioration. Each item of survival craft must be of good quality and efficient for the purpose it is intended to serve. Repair or replace lifefloats in accordance with manufacturer’s instructions.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 November 2019
No resolution recorded
02 Ring life buoys didn’t have proper retro-reflective material. Each ring life buoy must be marked with type II retro-reflective materials in accordance with 46CFR164.018. Install retro-reflective material to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 November 2019
No resolution recorded
Connections for batteries in both lights for ring life buoys and all 3 battery connections for lifefloats are
the spring type. Connections must be made to battery
terminals with permanent type connectors. Properly
connect battery connections.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 November 2019
No resolution recorded
One lifefloat paddle broken. Each item of survival equipment must be of good quality and efficient for the purpose it is intended to serve. Repair or replace lifefloat paddle.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 November 2019
No resolution recorded
All 6 lifefloat paddles are missing labeling. The name of the vessel must be marked or painted in clearly legible letters on each lifefloat paddle. Mark paddles.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 November 2019
No resolution recorded
Conduit between compartments 3 and 4 is not sealed on the engine room side. Penetrations in watertight bulkheads must be watertight. Make watertight.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 November 2019
No resolution recorded
Bilge pipe between compartments 3 and 4 was removed. Penetrations in watertight bulkheads must be watertight. Make watertight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2019
No resolution recorded
Vessel’s fuel shutoff valves at the tank connection didn’t close fuel supply lines entirely. Must be installed so as to close against fuel flow. Repair or replace to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 November 2019
No resolution recorded
Bilge suction in compartment 2 (bow thruster space) is not operable. Vessel of at least 26’ in length must be provided with individual bilge lines and suctions of each watertight compartment except forward of the collision bulkhead when ordinary leakage is removed be hand portable pump or other equipment. Repair or replace bilge suction in compartment 2 to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 November 2019
No resolution recorded
Engine room high level alarm did not produce audible and visual alarm at the operating station. Vessels of at least 26’ in length must provide visual and audible alarm at operating station to indicate a high water level in machinery space bilge. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 November 2019
No resolution recorded
Installed bilge system suction in lazarette is missing its strainer. A bilge suction must be fitted with a suitable strainer not less than three time the area of the bilge pipe. Install strainer to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2019
No resolution recorded
Starboard main engine sea suction hose clamp is broken flexible hose designed for use with hose clamps may be installed with 2 clamps at both ends of the hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 1 November 2019
No resolution recorded
Sewage tank straps on port side engine room are broken. Machinery, equipments, and arrangements may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 November 2019
No resolution recorded
enerator is set to operate at ambient temperature 40 degrees Celsius. Each generator must be designed for ambient temperature 50 degrees Celsius unless de-rated to 80% full load rating and setting of overcurrent devise is reduced accordingly. De-rate or replace generator and overcurrent devices.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2019
No resolution recorded
Starboard side main engine batteries had loose connections. Connection must be made to battery terminals with permanent type connectors. Replace with permanent type connectors.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 November 2019
No resolution recorded
Port side engine room missing structural fire protection overhead. Boundaries that separate machinery spaces from accommodation spaces must be lined with insulation approved in 164.009. Install insulation to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 November 2019
No resolution recorded
Extension cords found throughout engine room. Electrical
equipments on a vessel must be suitable for the voltage
and current utilized. Remove extension cords.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2019
No resolution recorded
Various steering gear and rudder mount hardware is wasted. Main steering gear must be of adequate strength and capable of steering the vessel at all service speeds. Provide repair proposal in accordance with vessel's original approved plans.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 November 2019
No resolution recorded
Sea suction to AC unit in compartment 3 is disabled. Pipes that penetrate the hull below the waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Remove or cap off.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 November 2019
No resolution recorded
Conduit in compartment 3 does not have drain holes. Horizontal pipe used for protection shall have .25” holes for drainage every 5 feet. Install drain holes.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2019
No resolution recorded
In lazarette, port side exhaust hanger is broken. Exhaust piping must be properly supported by non-combustible hangers or blocks. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 November 2019
No resolution recorded
Dead ends wires present throughout vessel. Electrical equipment must be installed to protect passengers, crew, other person, and vessel from electrical hazards. Remove or install junction box to secure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2019
No resolution recorded
First aid kit missing contents. A vessel must carry first aid kit approved under approval series 160.041 or kit with equivalent contents and instructions. Replenish contents.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2019
No resolution recorded
Vessel's posted COI is invalid. Vessels may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Post updated COI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 November 2019
No resolution recorded
Vessel's posted Certification Expiration Date Stickers are invalid. Vessels under the provisions of this subchapter must not be operated without a valid Certification Expiration Date sticker affixed to the vessel. Post updated Certification Expiration Date stickers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2019
No resolution recorded
Vessel is late in completing its annual inspection.Vessels must undergo an annual inspection within 3 months before and after each anniversary date. Complete annual inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 1 November 2019
No resolution recorded
Bow thruster space overhead above the anchor is rotten. Submit repair proposal in accordance with vessel's original approved plans to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2019 — due date passed with no resolution recorded
Fire Fighting › Fire Pumps › Pressure
Issued 11 August 2017
Resolved
Vessel's fire pump will not produce the minimum of 60 psi at the pump outlet. Owner must prove proper operation of installed fire pump to the attending Marine Inspector. 46CFR181.300(b). Vessels passenger count is restricted to carrying not more than 49 passengers.
Condition: Improper Installation
Due 24 August 2017
Resolved 26 October 2017
Resolution: Amended vessels COI to reflect maximum passengers of 49 thus no longer requiring the vessel to have a self priming power driven power pump.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 July 2017
Resolved
Vessel does not have alcohol testing devices readily accessible. Provide valid and approved testing devices.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 27 July 2017
Resolution: Vessel provided alcohol testing devices.
Fire Fighting › Fire Pumps › Pressure
Issued 14 July 2017
Resolved
Vessel's fire pump gauge is inoperative. Replace gauge and show proper operation and psi for pump.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 11 August 2017
Resolution: Owner/operator installed new gauge.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 July 2017
Resolved
Waterlights are not attached around the body of the life floats. Attach floating waterlights to the body of the life floats.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 27 July 2017
Resolution: Verified waterlights are attached to life floats.
Lifesaving › Lifefloat › Float Free
Issued 14 July 2017
Resolved
Life floats are stowed in a tier without spaces. Place spaces between each life floats.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 28 July 2017
Resolution: Verified spacers are placed between life floats.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 29 July 2016
Resolved
Found mast light was obstructed by radar, mast light will need to be elevated above any obstruction.
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 23 September 2016
Resolution: Verified that the masthead light had been elevated above the installed radar dome and was made visible as required by regulation.
Electrical › Electric Supply System (service) › Cable
Issued 29 July 2016
Resolved
Found multiple dead end wires, cap or remove.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 29 August 2016
Resolution: Upon examination during def-check, found that all dead-ended wires and all other wires not in use had been removed from underneath the operating station.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 July 2016
Resolved
found P.A. System power supplied using extension cords, make permanent installation.
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 29 August 2016
Resolution: Vessel owner removed all temporary wiring arrangements and installed permanent wiring for the fixed PA system; all sat.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 29 July 2016
Resolved
Found rotten wood in aft cabin bulkhead, renew rotted footer on aft cabin bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 29 August 2016
Resolution: Found that all rotten wood in lower portion of aft pilothouse bulkhead had been removed and renewed with good wood; all sat.
Lifesaving › Hand Flares › Not on Board
Issued 29 July 2016
Resolved
missing 3 orange hand smoke flares, replace in-kind
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 5 August 2016
Resolution: [name withheld] received evidence of purchase of three CG-approved orange smoke hand flares; all sat.
Lifesaving › Lifefloat › Serviceable
Issued 29 July 2016
Resolved
found on all 03 three life floats vinyl was deteriorating, repair IAW MFG instructions or renew as original.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2016
Resolved 11 May 2017
Resolution: MI inspected 03 life floats, the floats were repaired IAW manufactures instructions.
Construction/Loadline › Structures › Deck Plating
Issued 4 June 2016
Resolved
Make permanent repair to forepeak main deck underneath H-bit.
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 21 June 2016
Resolution: Examined the permanent repair made to the forepeak main deck underneath the H-bit; all sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 May 2016
Resolved
Complete required Drydock exam to the satisfaction of attending CG Marine Inspector IAW 46 CFR 176.600 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2016
Resolution: Completed all repairs and cleared all worklist items.
Electrical › Electric Supply System (service) › Cable
Issued 5 August 2014
Resolved
Incorrect electrical cable used for starboard side battery/starter cable. Replace with USCG approved/marine type to the satisfaction of attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 4 September 2014
Resolved 4 September 2014
Resolution: Replaced welding cable with USCG approved marine grade cables.
Stability › Watertight Integrity › General
Issued 5 August 2014
Resolved
03 hatch covers not secured to hatch frame to prevent its loss. Attach 03 hatch covers to the satisfaction of attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 19 August 2014
Resolved 19 August 2014
Resolution: O/O secured 03 hatch covers to frame; all sat.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 August 2014
Resolved
Vessel does not have copy of COD. Provide proof/copy of COD to the satisfaction of attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 19 August 2014
Resolved 19 August 2014
Resolution: O/O provide original copy of valid COD and is maintained on vessel; all sat.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 5 August 2014
Resolved
Service reports for fire protection equipment were not available. Provide proof of servicing of fire protection equipment to the satisfaction to attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 19 August 2014
Resolved 19 August 2014
Resolution: O/O provided valid service reports for fire protection equipment; all sat.
Fire Fighting › Fire Pumps › Arrangement
Issued 5 August 2014
Resolved
Fire pump does not have capability of local operation at the pump. Submit plan to USCG Marine Inspector detailing requirement for local operation at the fire pump.
Action required: 705 - Other - as specified
Due 4 September 2014
Resolved 4 September 2014
Resolution: O/O hired electricians to address deficiency; submitted plan with drawing to install three-way switches that will start/stop fire pump from the operating station and at the pump; all sat.
Construction/Loadline › Hull › Side Shell
Issued 21 March 2014
Resolved
During the vessels 2014 scheduled hull examination, attending inspectors discovered the vessel representative conducting repairs to the port quarter bulwark/ deck rail and port/starboard side shell/ transom joints. Notification and approval for repairs not given by local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 April 2014
Resolution: Repairs to the deck rail/ bulwark and to the vessels hull were completed satisfactorily.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 May 2012
Resolved
Improper navigation light configuration. Vessel is 65 ft and only has running lights and a combination masthead light/ all around white light located on top of the pilothouse. Vessel required to have a stern light placed as nearly practicable at the stern showing an unbroken arc of visibility of 135 degrees. 33 CFR 83
Action required: 705 - Other - as specified
Due 9 May 2012
Resolved 4 May 2012
Resolution: Stern light correctly mounted to the vessels stern. Operational test sat. Vessel now has the lights required by the Inland Navigation Rules, 33 CFR 83.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 2 May 2012
Resolved
One master (of 2) is not in compliance with mandatory drug testing regulations; prior to that master working as master, prove full compliance w mandatory drug testing requirements IAW 46 CFR 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2012
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 2 May 2012
Resolved
One deckhand (of 2) is not in compliance with the mandatory drug testing regulations; prior to that deckhand working as deckhand, prove full compliance w mandatory drug testing requirements.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2012
Resolved 3 May 2013
Resolution: All persons proved compliance with mandatory drug testing regulations.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 20 March 2008
Resolved
Provide proof of enrollment in a drug testing program and provide onboard 2hr alcohol testing kits for all crewmembers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2008
Resolved 6 May 2008
Resolution: Vessel provided proof of drug enrollment.
Documentation › Certificates/Documents › FCC SSL
Issued 20 March 2008
Resolved
Provide proof of valid FCC certificates to include Station License and Safety Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2008
Resolved 6 May 2008
Resolution: ALL FCC certificates posted and on board.
Documentation › Markings/Placards › Warning Signs
Issued 20 March 2008
Resolved
Post emergency instructions so they are accessable to passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2008
Resolved 6 May 2008
Resolution: Emergency information posted.