MAURY USCG vessel records Sign in
← All vessels

MATSON WAIKIKI

MATSON WAIKIKI is a freight ship. The Coast Guard has recorded 17 inspections since 2008, most recently in June 2026, along with 5 deficiencies and 2 operational controls.

Records from 2008 to 2026. Most recent: inspection, 29 June 2026.

Built
Not recorded
Last inspected
29 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9349801 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
942084
Flag
LIBERIA
—
Maury page id
psix-942084

Inspections, by type

…with no type recorded2
Years with a record 9 calendar years (2008–2026)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it30224 - Convention (Subpart B), Net Ton
63352 - Dead Weight, Metric Ton
82672 - Displacement, Metric Ton
50963 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

29 June 2026 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8418545
27 October 2025 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8259278
19 March 2025 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8094142
17 December 2024 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8045208
20 August 2024 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7979981
23 April 2024 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7900042
22 April 2024 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7899512
2 February 2024 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7857556
20 April 2023 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7672201
24 November 2021 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7355637
18 August 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7290417
9 November 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5759773
5 October 2015 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5736159
14 September 2015 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5717833
26 September 2011 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4154171
19 January 2009 ISPS III Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3396071
6 April 2008 ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3178420

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 February 2024 Resolved
THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: FIRE DETECTION AND FIRE ALARM SYSTEMS. PSCO OBSERVED 04 INOPERABLE SMOKE DETECTORS, 02 IN ECR, 01 ABOVE THE INCINERATOR, AND 01 ABOVE THE GENERATOR SPACE. 74 SOLAS (2004 CONS. ED.) II-2/14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2024
Resolution: Documentation received from class attesting to rectification of the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 20 April 2023 Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEM AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE IN WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES, AND OTHER HAZARDS. THE DESIGN SHALL HAVE REGARD TO MATERIALS USED IN CONSTRUCTION, THE PURPOSE FOR WHICH IT WILL BE SUBJECTED AND THE ENVIRONMENTAL CONDITIONS ON BOARD. PSCO OBSERVED POOLING OIL IN THE ENGINE ROOM ON THE MAIN ENGINE, BY A FUEL OIL PURIFIER, AND ON PIPING LAGGING. PSCO OBSERVED GENERAL LACK OF CLEANLINESS WITHIN THE STEERING GEAR ROOM. 74 SOLAS (04) II-1/26.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 28 April 2023
Resolution: sent class report detailing assurance that the oily lagging was replaced and additional management to ensure maintenance dailies are performed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 November 2021 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Self-closing door leading to galley did not operate as intended. 74SOLAS(2009)II-2 14.2.1.1
Action required: 10 - Deficiency Rectified
Resolved 24 November 2021
Resolution: Engineers made repairs to self-closing mechanism.
Construction/Loadline › Markings › Load Line Mark
Issued 14 September 2015 Resolved
1200 - Load lines - The ring lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. Port and Starboard deck lines are not contrasting colors relating to the hull. ICLL 66/88-Annex 1/reg.8
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 October 2015
Resolution: Received, reviewed and accapted class report from DNV GL stating the deficiency was rectified. Both deck lines were painted white by the ship's crew and subsequently surveyed by the DNV GL surveyor.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 26 September 2011 Resolved
0750 - Fire Prevention - Fire control plans shall be kept up to date. Fire plan has B deck galley area doors marked as self closing. However, no doors in the galley area are equipped with self closing mechanisms. SOLAS II-2/15.2.4.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 September 2015
Resolved 14 September 2015
Resolution: PSC team inspected fire control plan and doors leadig into the galley. All doors match the fire control plan.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.