AGIOS CHARALAMBOS is a 2007 tank ship. The Coast Guard has recorded 6 inspections since 2018, most recently in June 2025, along with 6 deficiencies and 1 operational control.
Records from 2018 to 2025. Most recent: inspection, 3 June 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it13712 - Convention (Subpart B), Net Ton 62030 - Displacement, Metric Ton 50922 - Dead Weight, Metric Ton 30119 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
6 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 6
3 June 2025COC-TVE Renew · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8150632
3 June 2025Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8150881
31 May 2025Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8148730
24 July 2023Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7751826
11 July 2023COC-TVE Renew · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7739933
15 October 2018COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6557507
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 12 July 2023Resolved
The arrangement of the water seal, or equivalent devices, and its associated fittings shall be such that it will prevent backflow of yapours and liquids and will ensure the proper functioning of the seal under operating conditions. PSCO observes bottom of deck water seal leaking water and area of leak with a temporary putty patch.
74 SOLAS (2020)4.5.5.1.1
FFS Code 15.2.2.3.1.5
50 a,c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2023
Resolved 16 July 2023
Resolution: Reviewed class report and attended vessel to verify.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 July 2023Resolved
Instrumentation shall be fitted for continuously indicating and permanently recording when inert gas is being supplied... the oxygen content of the inert gas. PSCO observed the cheif engineer unable to successfully calibrate the servomex 1800 mv O2 analyzer.
74 SOLAS (2020) 4.5.5.1.1
FSS Code 15.2.2.4.2
50 a,c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2023
Resolved 16 July 2023
Resolution: Reviewed class report and attended vessel to verify.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 July 2023Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed explosion proof lighting near STBD stairs to focsle has a cracked lense. Vessel in ballast.
74 SOLAS (2004) II-1/45.1.3
50 a,c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2023
Resolved 16 July 2023
Resolution: Reviewed class report and attended vessel to verify.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 July 2023Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed numerous leaks from flanges on deck fresh water lines up to #5 cargo tanks. PSCO additionally observed air filter for cargo heater temperature controller in cargo heating room wasted. Fresh water inlet for ODME line on decks. PSCO observed with water leak.
74 SOLAS (2020) I/11(a)
50 a,c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2023
Resolved 16 July 2023
Resolution: Reviewed class report and attended vessel to verify.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 July 2023Resolved
Detailed instruction manuals shall be provided on board, covering the operationsm safety and maintenance requirements and occupational health hazards relevant to the inert gas system and its application to the cargo tank system. The manuals shall include guidance on procedures to be followed in the event of a fault or failure of the inert gas system. PSCO observed manual for inert gas system O2 analyzer, "servomex 1800 mv marine oxygen analyzer" does not contain calibration procedures.
74 SOLAS (2020) 4.5.5.1.1
FSS Code 15.2.2.5
50 a,c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2023
Resolved 16 July 2023
Resolution: Reviewed class report and attended vessel to verify.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 October 2018Resolved
04114- Emergency Systems-The power available shall be sufficient to supply all those services which are, in the opinion of the Administration, necessary for the safety of all on board in an emergency, due regard being paid to such services as may have to be operated simultaneously. PSCOs observed emergency generator to hunt for approximately three minutes while in primary means of starting. Emergency generator would also hunt while in secondary means of starting.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 October 2018
Resolution: 16OCT18: Received class report from RINA stating all outstanding deficiencies have been rectified. The class report stated: permanent repairs to the emergency generator have been made by changing the filter and as extra precaution, drained and replaced th