LILA VANCOUVER is a 2008 tank ship. The Coast Guard has recorded 13 inspections since 2017, most recently in August 2026, along with 3 deficiencies and 1 operational control.
Records from 2017 to 2026. Most recent: inspection, 3 August 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it6301 - Convention (Subpart B), Net Ton 25121 - Displacement, Metric Ton 19702 - Dead Weight, Metric Ton 11653 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 20 August 2024Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel must properly maintain the BWMS in accordance with all manufacturer specifications. Vessel's ballast water management system is inoperable. Vessel shall not discharge ballast water into U.S. waters. Vessel plans to take on ballast water at Port of Stockton while at berth and will not discharge ballast in port or within 12 nm of U.S. waters.
33CFR151.2025(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 December 2024
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 5 January 2018Resolved
0999-Other (Safety In General)- Where cables which are installed in hazardous area introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the administration. PSCO observed cargo discharge pump emergency stop button located at the starboard manifold with modified electrical wiring not approved for use within the hazardous location. Vessel is prevented from loading a liquid cargo with a flash point of less than 60 degrees C while operating within the United States. SOLAS (04) II-I /45.5.4 ac
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 6 January 2018
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Electrical box housing and cabling have been renewed with proper packing gland, making it safe for hazardous areas.
1199- Other(cargo)- The machinery, boilers and other pressure vessels associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce the minimize any danger to persons on board, due regard being to moving parts hot surfaces and other hazards. PSCO observed a hydraulic line pinhole leak IWO of 9 STBD cargo pump. SOLAS (04) II-1/26.1 40a
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 August 2020
Resolution: Received class report clearing the def, all sat.