Records from 2016 to 2026. Most recent: inspection, 29 January 2026.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2008
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portISLAMORADA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Simplified, Net Ton
44 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
29 January 2026
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8303646
27 October 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8249059
4 December 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8033229
30 September 2024
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7987454
17 January 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7850269
11 January 2023
Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7619748
4 October 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7576095
1 March 2022
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7404781
13 April 2021
Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7175129
15 October 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7078469
28 August 2020
Simplified Stability Test · Damage Survey · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7048518
11 May 2020
Annual Inspection · Internal Structural Exam · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6955179
6 March 2019
Internal Structural Exam · Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6637141
29 October 2018
DAPI Audit · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6570521
13 February 2018
COI Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6354484
25 September 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294394
11 May 2017
Internal Structural Exam · Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6285538
13 September 2016
Examination of Repairs · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6000547
10 March 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5830303
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 27 October 2025
Resolved
Fire dampners need to have a way of securing them in place after they are pulled they fall back down. Install something to hold them in place when in use.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2025
Resolved 30 October 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 December 2024
Resolved
The words "FIRE BUCKET" must be stenciled in contrasting color on each bucket. Buckets only say FIRE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2024
Resolved 4 December 2024
Resolution: Buckets have been labeled correctly.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 December 2024
Resolved
Alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred. Alcohol swabs are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2024
Resolved 9 December 2024
Resolution: Captain has alcohol swabs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 December 2024
Resolved
02 bonding wires for electrical system have broken off of both rudders. Repair/replace wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2024
Resolved 4 December 2024
Resolution: Bonding wires have been repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 January 2024
Resolved
Life ring grab line was dry rotted and starting to fray. Replace grab line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2024
Resolved 28 February 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 March 2022
Resolved
Aft bilge high water alarm light is not working. Must make repairs and test to the satisfaction of attending CG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2022
Resolution: Installed new light
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 April 2021
Resolved
Port NAV light lens is "Frosted" over and does not meet the 2 mile requirement. Clean or replace NAV light lens.
NAV RULES
COLREGS
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 13 April 2021
Resolution: Had new lens in storage. Replaced, All SAT
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 28 August 2020
Resolved
While at the shipyard looking this vessel on blocks for a repower project, found the keel to be cracked where its sitting on the block. Must conduct repairs to the satifaction of attending CG Marine Inspector
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 30 September 2020
Resolved 6 November 2020
Resolution: Keel was grinded down to remove all defects, new fiberglass laid down and built back to factory spec's, all SAT
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2019
Resolved
Eisen glass windshield is wasted and must be removed or renewed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 March 2019
Resolution: Glass was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 March 2019
Resolved
Repair water leak on shaft seal and raw water pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 March 2019
Resolution: New Water seal was installed and tested.
Communications › Radio Communications › EPIRB
Issued 11 May 2017
Resolved
EPIRB Battery is expired. Renew.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 25 May 2017
Resolution: New EPIRB was installed and tested. All sat
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 May 2017
Resolved
34 adult PFD were not serviceable.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 25 May 2017
Resolution: new PFD were supplied.
Lifesaving › Lifefloat › Retroreflective Material
Issued 11 May 2017
Resolved
Reflective material on lifefloat was missing or damaged, and must be renewed.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 25 May 2017
Resolution: New reflective tape was installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 May 2017
Resolved
life ring lanyard is wasted and must be renewed.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 25 May 2017
Resolution: New lanyard was installed.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 11 May 2017
Resolved
All navigation publications are out of date.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 25 May 2017
Resolution: New publications were provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2017
Resolved
first aid kit is missing contents.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 25 May 2017
Resolution: new kit was provided.