Records from 2016 to 2026. Most recent: inspection, 23 February 2026.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 12.0 ft × 3.5 ft
Registered tonnagegross 10 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPUMPOUT USA INC DBA DC BROWN CUSTOM BOATWORKS · Defuniak Springs, FL, UNITED STATES · built 2007
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Net Ton
10 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
23 February 2026
Annual Inspection · Administrative Inspection · Special Consideration · Vessel Attendance · Plan Review "T" Boat
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8314729
12 January 2026
Drydock Exam · Internal Structural Exam · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8295134
10 March 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8091374
9 May 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7909451
6 March 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7874779
22 January 2024
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7853276
13 February 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7636407
12 January 2022
Drydock Exam · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7382979
10 August 2017
DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6229384
2 August 2017
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6228705
25 April 2017
Hull Examination · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6132065
4 October 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6007897
13 September 2016
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5999838
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 6 March 2024
Resolved
The vessel requires bilge high level alarms in all spaces with hull valves. The two high water alarms did not work as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 9 May 2024
Resolution: Corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 10 August 2017
Resolved
Provide one BI fire extinguisher
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2017
Resolved 11 August 2017
Resolution: Vessel provided fire extinguisher
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 August 2017
Resolved
Provide battery box cover
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 11 August 2017
Resolution: Vessel provided cover.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 August 2017
Resolved
Complete a credit annual exam. Vessel annual exam is overdue as of 16Jul17.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 11 August 2017
Resolution: Vessel completed a credit annual exam.
Construction/Loadline › Structures › Superstructure
Issued 25 April 2017
Resolved
Repair 4 identified crack welds
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 2 May 2017
Resolution: Vessel repaired cracked welds
Deck/Cargo › Holds/Tanks › Scuttle
Issued 25 April 2017
Resolved
Remove water from portside fwd hold
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 2 May 2017
Resolution: Vessel removed water from hold
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 October 2016
Resolved
COD was expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 10 November 2016
Resolution: COD was provided.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 October 2016
Resolved
4 Life Jackets were missing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 10 November 2016
Resolution: Four life jackets were provided.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 October 2016
Resolved
Light and life line on ring bouy was not present.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2016
Resolved 10 November 2016
Resolution: The light and life line on the ring bouy was provided.
Fire Fighting › Fire Bucket › Availability
Issued 4 October 2016
Resolved
Fire buckets were not 2 and a half gallons and not stenciled fire bucket.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2016
Resolved 10 November 2016
Resolution: Fire buckets have been stenciled and made to self bail to 2 and one half gallons.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 October 2016
Resolved
High level alarm indicator light was not functioning.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2016
Resolved 5 January 2017
Engineering › Steering Gear System › Differential Assembly
Issued 4 October 2016
Resolved
Steering failed while underway.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2016
Resolved 10 November 2016
Resolution: Steering system has been repaired.
Fire Fighting › Fire Bucket › Availability
Issued 4 October 2016
Resolved
Fire extinguisher bracket was inoperable.
Condition: Invalid
Due 25 October 2016
Resolved 10 November 2016
Resolution: Fire extinguisher brackets have been replaced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 September 2016
Resolved
Complete a credit annual exam. Vessel annual is overdue as of 16Jul16.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2016
Resolved 31 October 2016
Resolution: Annual completed