MAURY USCG vessel records
← All vessels

LR1 AMBASSADOR

LR1 AMBASSADOR is a 2007 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in January 2026, along with 10 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: operational control imposed, 25 January 2026.

Built
2007
Last inspected
25 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 January 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9307085
942714
Flag
LIBERIA
Maury page id
psix-942714

Documentation record

Tonnage as PSIX records it22382 - Convention (Subpart B), Net Ton
89187 - Displacement, Metric Ton
73584 - Dead Weight, Metric Ton
42010 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

25 January 2026 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8301445
6 October 2025 PSC B · COC-TVE Annual · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8243927
30 September 2024 PSC B · In-Service Inspection · Deficiency Check · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8009773
26 September 2024 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8009597
7 May 2024 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7908113
3 September 2023 COC-TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7778672
10 August 2022 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7527820
21 July 2021 COC-TVE Annual
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7263466
9 August 2020 COC-TVE Renew · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7013960
23 July 2019 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6758476
7 March 2019 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6637916
6 March 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6637639
17 December 2018 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6598960
13 October 2018 Administrative Inspection · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6560475
20 August 2018 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6515091
14 March 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6104741
8 March 2017 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6098000
28 June 2016 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5922926
15 April 2016 ISPS II Exam · Ballast Water Examination · COC-TVE Annual · COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5849557

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 September 2024 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTABLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED FUEL OIL LEAKS ON THE MAIN ENGINE ON AL INJECTORS AND BOOSTER PUMPS. ADDITIONALLY, PSCO OBSERVED POOLED FUEL OIL ON THE EXHAUST SIDE OF THE MAIN ENGINE. 74SOLAS(04)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 September 2024
Resolved 1 October 2024
Resolution: RINA sent a satisfactory Class report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 September 2024 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTABLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED OIL LEAKS ON ALL THREE CARGO PUMPS AND THE 2 STRIPPING PUMPS IN THE CARGO PUMP ROOM. 74SOLAS(04)II-2.4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2024
Resolved 1 October 2024
Resolution: RINA sent a satisfactory Class report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 September 2024 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTABLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED F/O LEAKS ON A/E 1 AND STARBOARD DIESEL OIL SETTLING TANK. 74SOLAS(04)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2024
Resolved 1 October 2024
Resolution: RINA sent a satisfactory Class report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 September 2024 Resolved
A TANKER CARRYING CRUDE OIL SHALL HAVE ON BOARD AND IMPLEMENT A VOC MANAGEMENT PLAN APPROVED BY THE ADMINISTRATION. PSCO OBSERVED P/V VALVES ON DECK SET TO 1600mmWG, DESPITE VESSEL'S VOC MANAGEMENT PLAN REQUIRING A PRESSURE SETTING OF 1700mmWG. MARPOL VI/15.6
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 September 2024
Resolved 1 October 2024
Resolution: RINA sent a satisfactory Class report.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 30 September 2024 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO OBSERVED INSTALLED AUDIBLE ALARM IN THE STEERING GEAR ROOM INOPERABLE. 74SOLAS(20)I/11
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 September 2024
Resolved 1 October 2024
Resolution: RINA sent a satisfactory Class report.
09 - Working and Living Conditions › 092 - Working Conditions › Emergency cleaning devices
Issued 30 September 2024 Resolved
WHERE CABLES WHICH ARE INSTALLED IN HAZARDOUS AREAS INTRODUCE THE RISK OF FIRE OR EXPLOSION IN THE EVENT OF AN ELECTRICAL FAULT IN SUCH AREAS, SPECIAL PRECAUTIONS AGAINST SUCH RISKS SHALL EB TAKEN TO THE SATISFACTION OF THE ADMINISTRATION. PSCO OBSERVED EXPOSED WIRING ON A PRESSURE SENSOR ON THE STARBOARD MANIFOLD. 74SOLAS(04)II-1/45.5.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 September 2024
Resolved 30 September 2024
Resolution: RINA sent a satisfactory Class report.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 September 2023 Resolved
Conditions of the ship and its equipment shall be maintained. It was observed in the upper level of the pump room multiple hydraulic oil lines leaks and at the stripping pump discharge. Clean and effect repairs prior to cargo. SOLAS 74am, I/11., Prior to Cargo
Action required: 705 - Other - as specified
Due 4 September 2023
Resolved 4 September 2023
Resolution: Received, reviewed and accepted Class Report from RINA attesting to the cleaned up hydraulic oil leaks and repair to the stripping pump flange assembly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 August 2020 Resolved
The rings, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The marks shall be plainly visible. Parts of port and starboard load lines were not visible. ICLL 8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 September 2020
Resolution: Vessel submitted pictures and a statement verifying that the load line was repainted and is now visible.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 August 2018 Resolved
1830 - Each tankship with a vapor collection system must be fitted with a prssure-sensing device. Panel for the pressure-sensing device located in the CCR does not give audible and visible alarms. 46CFR39.2013 40c
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 November 2018
Resolution: Deficiency cleared.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 8 March 2017 Resolved
0899-Interlocks should be installed to prevent ash removal doors from opening while burning is in progress or while the furnace temperature is above 200 degrees celsius During operational test of incinerator the door interlock switch failed allowing for full combustion of system with the waste door open. Def code-0899 MARPOL VI/16.6.1 MEPC 76(40).3.1.2 16ac
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 14 March 2017
Resolution: Received class report clearing deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.