MISS FISHERMAN'S WHARF

MISS FISHERMAN'S WHARF is a 1944 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in April 2026, along with 35 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 27 April 2026.

Built
1944
Last inspected
27 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

943064
Flag
UNITED STATES
Maury page id
psix-943064

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
6 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

27 April 2026 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8361651
17 April 2025 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8113985
14 February 2024 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7866226
10 January 2024 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7848777
11 January 2023 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7621074
26 January 2022 Drydock Exam · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7388236
7 September 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7309056
5 March 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7151008
15 July 2020 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7002728
26 March 2019 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6660506
30 September 2018 Simplified Stability Test · Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6569021
25 July 2018 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6507231
19 April 2018 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6395616
24 January 2017 Internal Structural Exam · Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6076971
22 September 2016 DAPI Audit
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6012362
17 August 2016 Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5994807
11 February 2016 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5814455
2 February 2016 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5812853

Deficiency record · 35

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2024 Resolved
The Vessel is required to process sistering information to Marine Safety Center(MSC) and get a stability letter prior to operating with full COI passenger count. The vessel is restricted to the carriage of 26 passengers and 1 crew member until the stability test process is completed and approved. Complete prior to August 30th 2024.
Action required: 705 - Other - as specified
Due 10 March 2024
Resolved 10 October 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 February 2024 Resolved
Fire Extinguishers were not in an approved bracket. Owner shall have Fire extinguishers in approved brackets.
Action required: 705 - Other - as specified
Due 16 February 2024
Resolved 16 February 2024
Resolution: Vessel owner install brackets for the Fire extinguishers.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 February 2024 Resolved
Stern Nav Light is not visiable from the front of the vessel. Stern Light shall Be visiable to on coming vessels while operating.
Action required: 705 - Other - as specified
Due 16 February 2024
Resolved 16 February 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2024 Resolved
Batteries on the vessel were not in a approved container. Batteries must be placed in an approved container for the type of battery to protect from accidental spark.
Action required: 705 - Other - as specified
Due 16 February 2024
Resolved 16 February 2024
Resolution: Owner has BAtteries in approved containers.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2024 Resolved
Vessel is under going the modifications required by 46CFR175.124. Vessel will not be able to carry passengers in accordance with the COI until the requirements of the regulations are met.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2024
Resolution: Vessel met NDA requirements, But waiting on Stability information from Sister vessel. See new deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 January 2023 Resolved
Vessel missing 09 of the required XX Adult PFD's. Owner/Operator shall insure that the PFD's onboard the vessel meets or exceeds the amount on the COI for the Safety of passengers on board.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 January 2023
Resolved 11 January 2023
Resolution: Vessel owner provided photos of 09 New PFD's prior to arriving back to the unit. Vessel Owner was notified of the def and rectified immediately.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 January 2022 Resolved
Vessel does not have shut off valves at the hull penetrations on the port side for the radiator hoses. Install valves in this location with in 30 days.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 January 2022 Resolved
Vessel does not have shut off valves at the hull penetrations on the front of the engine compartment for the hoses going to the deferential of the axle. Install valves in this location with in 30 days.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 January 2022 Resolved
Replace retro reflective tape on six adult PFD's and on one Child PFD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 24 March 2022
Resolution: Vessel replaced Retro Reflective tape on PFD's
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 January 2022 Resolved
Properly mark and stow PFD's in the correct vessel. Adult PFD's and Child PFD's shall be stowed and marked in the proper locations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 24 March 2022
Resolution: Vessels Owner properly marked and stowed PFD's on board the vessel.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 January 2022 Resolved
Portable fire extinguisher on the starboard side of the driver station has a broken bracket. Repair in accordance with the manufactures recommendation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 28 April 2022
Resolution: Vessel Owner repair Fire extingisher bracket
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 January 2022 Resolved
Vessel operator is unable to show the fuel is shut off after operating the emergency fuel shut off. Owner shall provide an indicator for the fuel shut off.
Action required: 705 - Other - as specified
Due 30 March 2022
Resolved 24 March 2022
Resolution: Vessel owner installed valve to show the fuel valve is open or shut.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 January 2022 Resolved
Fire Fighting equipment servicing is expired. All fighting equipment shall be serviced annually. Provided servicing documentation prior to embarking passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2022
Resolved 24 March 2022
Resolution: Vessel had Fighter extinguishers inspected and approved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2021 Resolved
Vessels upper radiator hose failed which made the engine water temp rise above normal operating temps. Vessel operatorshall replace radiator hose in accordance with manufactures recommendation and have aMArine inspector oboard to test proir to carrying passengers on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2021
Resolution: Vessel Operator replaced the upper radiator hose and was inspected and tested underway while CG MI was onboard
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2021 Resolved
The COI shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the certificates must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. The vessel does not maintain a valid COI on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2021
Resolution: COI installed in lockbox on vessel due to open vessel design.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 5 March 2021 Resolved
The stability letter shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. The vessel does not maintain a valid stability letter on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2021
Resolution: Stability Letter is onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021 Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets are not stowed separately.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: Child sized life jackets are stowed separately.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2021 Resolved
All electrical equipment and circuits must be clearly marked and identified. The Navigation lights at the operating station are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: NAV lights clearly marked.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2021 Resolved
All vessels must have navigation lights that are in compliance with Inland Navigation Rules. Navigation lights were not illuminating.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2021
Resolution: Installed new nav lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2021 Resolved
Each life ring on a vessel must be approved under 160.050, be readily accessible, be stowed in a way that it can be rapidly cast loose, and not permanently secured in anyway. The life ring w/ line was not stowed in a fashion that allowed for it to be rapidly cast loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: Lifebuoy able to be rapidly cast loose.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 March 2021 Resolved
An enclosed space containing machinery powered by gasoline must be equipped with a flammable vapor detection device in compliance with 46 CFR 182.480. The vapor detection alarm was not functioning.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2021
Resolution: Installed new vapor detection alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 July 2020 Resolved
Replace seals around engine compartment hatch, front ventilation hatch and rear door.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 15 July 2020 Resolved
Clean bilge of all debris and oil.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 15 July 2020 Resolved
Permanent plug vent at bottom of gunwale on port side below operators seat.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 March 2019 Resolved
Pinhole leak found in starboard aft wheel well. Was repaired to the satisfaction of attending MI.
Action required: 10 - Deficiency Rectified
Resolved 26 March 2019
Resolution: Repaired to the satisfaction of attending MI.
Personnel › Training › Passenger Safety
Issued 24 January 2017 Resolved
Crew training has not been conducted since last summer (AUG 16). Training for emergency procedures shall be conducted every three months. Conduct training prior to getting underway with passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2017
Resolved 2 February 2017
Resolution: Drills were completed.
Fire Fighting › Fire Bucket › Quantity
Issued 24 January 2017 Resolved
Vessel was missing 01 fire bucket. Replace fire bucket. Ensure it is properly stenciled.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 2 February 2017
Resolution: Fire buckets were replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 January 2017 Resolved
Found that the first aid kit was expired. Replace first aid kit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 December 2017
Resolved 2 February 2017
Resolution: First Aid Kit was replaced.
Communications › Audible Communications › Horn/Whistle
Issued 24 January 2017 Resolved
Sound signaling appliance (horn) on vessel did not operate. Demonstrate satisfactory operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 2 February 2017
Resolution: Tested horn satisfactory.
Stability › Watertight Integrity › General
Issued 24 January 2017 Resolved
Rear door where ladder is located does not have gasket material. Ensure gasket is re-installed prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2017
Resolved 2 February 2017
Resolution: Rear gasket material was replaced.
Documentation › Markings/Placards › Vessel Number (state)
Issued 24 January 2017 Resolved
Vessel was recently painted and did not have any hull markings. Mark name of the vessel on the port/starboard sides and stern. Mark hailing port on the stern. Markings must be at least 4 inches in height.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 2 February 2017
Resolution: Hailing port and name was re-painted on the vessel.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 24 January 2017 Resolved
Management Information System (MIS) Data Reporting has not been completed for 2016. Submit form U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection Form to Commandant (CG-INV) by March 15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 8 March 2017
Resolution: MIS reports were submitted.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 22 September 2016 Resolved
Owner/Operator did not have list of employees enrolled in random drug testing. Owner provided an email he sent to the Consortium requesting certain individuals be added to the random testing pool, but there was no confirmation from the Consortium. Provide letter from Consortium with list of employees enrolled in the program within 30 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 October 2016
Resolved 26 April 2017
Resolution: List was provided.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 February 2016 Resolved
Found 11 adult and 03 child lifejackets that were in poor condition (ripped, missing Q-Spec, retro-reflective tape, etc.). Provide satisfactory lifejackets (30 adult and 03 child) in accordance with Certificate of Inspection.
Condition: Improper/Lack of Maintenance
Due 2 March 2016
Resolved 11 February 2016
Resolution: Sat lifejackets were provided.
Lifesaving › Lifebuoys › Serviceable
Issued 2 February 2016 Resolved
Found that the lifebuoy onboard was marked with "DOT" approved retro reflective tape. Replace with "SOLAS" approved tape (Tape II) IAW 46 CFR 164.018.
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 11 February 2016
Resolution: lifebuoy was properly marked with SOLAS approved tape.

Ownership record