SIDARI is a 2007 freight ship. The Coast Guard has recorded 12 inspections since 2017, most recently in February 2026, along with 4 deficiencies and 2 operational controls.
Records from 2017 to 2026. Most recent: inspection, 11 February 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it25603 - Convention (Subpart B), Net Ton 75204 - Dead Weight, Metric Ton 87003 - Displacement, Metric Ton 40198 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 June 2019Resolved
07106-The fire detection and fire alarms shall be kept in good order so as to ensure their required performance if a fire occurs. The vessels fire alarms panel indicated a fault in Zone 3 for the Engine Room. SOLAS 74 (amended) II-2/14.2.1.1.3 Code 17ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 5 August 2020
Resolution: Received a Class Survey Report stating that the fire detection system was repaired and tested and found in good working condition.
1499-Other (Prop. & Aux Machinery)- Means shall be provided to control leaks of flammable liquids. PSCO observed excessive fuel oil leaks from injectors 1-5 and fuel pump number 4 on main engine. SOALS (04) 74 a II-2/4.1.1 60a
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 May 2018
Resolution: Received class report from ABS stating deficiency have been rectified. The class report stated: Changed o-rings on injectors and pump, tested under pressure and slow ahead start, no excessive oil leaks observed.
Lifesaving › Launching Appliances › Davit
Issued 2 May 2018Resolved
0635-launch arrangt. For rescue boats- Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. PSCO observed crew unable to launch and recover rescue boat with electrical winch. After approximately 20 minutes winch restored. PSCO also observed seized sheave on brake release cable causing cable to become unspooled. SOLAS (04) 74 a III/20 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 May 2018
Resolution: Crew conducted sat repair and operational test of rescue boat davit.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 2 May 2018Resolved
0715- Detection- maintenance testing and inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring the reliability of firefighting systems and appliances. PSCO observed crew testing on board flame detection system with a lighter. Crew could not provide documentation showing that was an approved testing method. SOLAS 74 a (04) II-2/14.2.2.1 16a
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2018
Resolved 2 May 2018
Resolution: Received class report from ABS stating deficiency has been rectified. The class report stated: Parts on order Issued a condition of class due 16MAY18.