Records from 2016 to 2026. Most recent: inspection, 13 April 2026.
Inspection history · 53
13 April 2026
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8338673
11 October 2025
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8250069
21 April 2025
COC-CVE Annual
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8113193
9 November 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8032520
2 November 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8028558
5 May 2024
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7906694
22 April 2024
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7899250
31 October 2023
COC-CVE Quarterly · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7815528
27 September 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7799504
22 June 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7720582
4 May 2023
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7680672
3 April 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7661938
21 December 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7611641
5 December 2022
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7603127
5 December 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7625708
10 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7574689
4 October 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7571173
1 October 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7569721
23 September 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7565098
7 June 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7471001
6 June 2022
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7465319
31 January 2022
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7390153
20 December 2021
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7367480
26 November 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7357937
30 July 2021
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7272621
25 July 2021
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7266818
16 June 2021
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7221441
27 February 2021
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7147994
24 February 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7145884
10 July 2020
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7002934
23 May 2020
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6991231
6 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dpw) · USCG Southeast District (CGD-SE) · Activity 6935905
30 October 2019
COC-CVE Annual
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6845331
14 June 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6713567
24 May 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6692440
13 May 2019
COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6680085
18 January 2019
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6611837
31 October 2018
COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6572072
7 August 2018
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6503234
27 July 2018
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6492439
17 May 2018
Ballast Water Examination · ISPS III Exam · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6416906
9 April 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6416820
1 April 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6985754
30 November 2017
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6315329
17 November 2017
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6305714
2 October 2017
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6279648
15 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6241088
19 May 2017
ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6150297
14 March 2017
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6104652
6 March 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6212928
28 November 2016
ISPS II Exam · Ballast Water Examination · COC-CVE Annual · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6048212
24 August 2016
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5981885
3 June 2016
COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5896434
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 April 2026
Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. In the backstage of the Buena Vista Theatre there was theatre supplies and a ladder stored in the way of the escape route.
74 SOLAS(20) II-2/13.1.2
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 April 2026
Resolution: Crew cleared escape route of all stowed items prior to Inspection team debarkation.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 April 2026
Resolved
Where a fixed fire-extinguishing system, not required by this chapter is installed, it shall meet the requirements of the relevant regulations of this chapter and the Fire Safety Systems Code. An empty amupule at the Safe Return to Port area was observed.
74 SOLAS(20) II-2/10.4.1.2
10c
Action required: 10 - Deficiency Rectified
Resolved 13 April 2026
Resolution: Crew replaced ampule prior to debarkation of Inspection team.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 April 2026
Resolved
It shall be possible for each door to be opened and closed from each side of the bulkhead by one person only. FD-03-3-011 was in the open position and would not close when released locally.
74 SOLAS(20) II-2/9.4.1.1.4
10c
Action required: 10 - Deficiency Rectified
Resolved 13 April 2026
Resolution: Crew made necessary electrical repairs to effect proper operation of FD-03-3-011 prior to Inspection team debarkation.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 9 November 2024
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begines. Three stairway guides in charge of passenger evacuation were not familiar with their duties and were not successfully guiding passengers to their evacuation station.
74 SOLAS (20) III/19.2.1
Code 17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2024
Resolution: Completed additional training with crew members.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 November 2024
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: .3 the ignitability of combustible materials shall be restricted. PSCO received a report from the vessel master of a class A fire in a garbage silo, the report stated that there were no known injuries to personnel and no known additional damages to other areas of the ship outside of the garbage silo but that the source of ignition is unknown.
74 SOLAS (20) CH. II-2 Reg. 4.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2024
Resolution: Cleared def with class document.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2022
Resolved
Vessel with voyage time less than 96 hours must submit a NOA before departure but at least 24 hours before arriving at port. Vessel submitted a notice of arrival at approximately 1353 on June 6th, 2022 from Cape Canaveral, FL and arrived at Miami, FL on June 7th, 2022 at or around 0600.
33CFR160.212(a)(4)(II)
Action required: 10 - Deficiency Rectified
Resolved 7 June 2022
Resolution: Vessel was notified of eNOA regulations and explained that Cape Canaveral is a separate COTP zone.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 16 June 2021
Resolved
Muster and Embarkation stations shall be adequeately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/42 or II-1/43, as appropriate. Emergency lighting on starboard embarkation deck at liferaft stations #1 and #7, as well as lifeboats #9 and #11 were not operable.
SOLAS 20 III/11.4
Action required: 10 - Deficiency Rectified
Due 16 June 2021
Resolved 16 June 2021
Resolution: Corrected on the spot
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 November 2019
Resolved
07101 - Fire prevention structural integrity - For the purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. Aft funnel cable penetration was observed open without proper structural fire protection. 74 SOLAS 09 con. II-2/9.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 November 2019
Resolved 4 November 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 November 2019
Resolved
07199 - Other (fire safety) - Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Waste receptacle in concierge pantry on deck 12 was made of plastic. 74 SOLAS 09 con. II-2/4.4.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 November 2019
Resolved 4 November 2019
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 November 2019
Resolved
07120 - Means of escape - Means of escape shall be marked by lighting or photo luminescent strip indicators. Deck 01, port side, aft steering gear corridor low location lighting was blocked by a 4 foot section of foot lockers. 74 SOLAS 09con. II-2/13.3.2.5.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 November 2019
Resolved 4 November 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 May 2019
Resolved
07105 - FIRE DOORS - SLIDING FIRE DOORS IN MAIN VERTICAL ZONE BULKHEADS SHALL BE DESIGNED TO RE-OPEN UPON CONTACTING AN OBJECT IN ITS PATH. UPON CONTACT FIRE DOOR 01-2-012 DID NOT RE-OPEN AND CONTINUED TO CLOSE. 74SOLAS(2009 CONS)II-2/9.4.1.1.4.11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 May 2019
Resolution: USCG inspectors witnessed fire door 01-2-012 was corrected on the spot and functioning properly.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 May 2019
Resolved
07105 - FIRE DOORS - THE CONSTRUCTION OF DOORS AND DOOR FRAMES IN "A" CLASS DIVISIONS, WITH THE MEANS OF SECURING THEM WHEN CLOSED, SHALL PROVIDE RESISTANCE TO FIRE AS WELL AS THE PASSAGE OF SMOKE AND FLAME EQUIVALENT TO THAT OF THE BULKHEADS IN WHICH THE DOORS ARE SITUATED. FIRE SCREEN DOOR 11-4-004 DOES NOT MEET THE STANDARD. 74SOLAS(2009 CONS) II-2/9.4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2019
Resolved 14 June 2019
Resolution: Vessel replaced the fire door. The boundary now meets the standard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 May 2019
Resolved
02108 - ELECTRICAL INSTALLATIONS - WHERE "A" CLASS DIVISIONS ARE PENTRATED, SUCH PENETRATIONS SHALL BE SUITABLY INSULATED BY EXTENSION OF THE INSULATION AT THE SAME LEVEL OF THE DIVISION. ELECTRICAL WIRE RUN PENETRATING AN A-0 BOUNDARY IN THE DECK 13 POOL MACHINERY ROOM IS MISSING INSULATION. 74SOLAS(2009 CONS) II-2/9.3.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 24 May 2019
Resolution: PSCOs observed sufficient insulation in the electrical wire run penetrating the "A0" boundary in the deck 13 pool machinery room. PSCOs also verified Class approval of sealant material.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 November 2017
Resolved
0799 - Other (Fire Fighting equipment) - Fire doors in main vertical zones and stairway enclosure shall close between 10 and 40 seconds. FSD's 06-1-004, 02-2-004 and 02-3-004 closed in less than 10 seconds. 74 SOLAS (09) CH II-2/Reg 9.4.1.1.4.2
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 17 November 2017
Resolution: Deficiency Rectified
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 November 2017
Resolved
0799 - other (Fire Fighting equipment) - Fire doors in main vertical zones and stairway enclosures shall close between 10 and 40 seconds. FSD's 31-3-006 and 31-4-002 do not latch. 74SOLAS(09) CHII-2/Reg 9.4.1.1.4.2
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 28 November 2017
Resolution: MSD Port Canaveral received correspondence from Lloyd's Register to attest to repairs of subject fire screen doors.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 November 2017
Resolved
0799 - Other (Fire fighting equipment) - Fire integrity of bulkheads and decks shall meet minimum integrity per table 9.1 and 9.2. Modifications were made to the deck and structural fire protection was not fitted at B deck at frame 257 starboard side. 74SOLAS(09) II-2/Reg 9.2.2.3
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 28 November 2017
Resolution: MSD Port Canaveral received correspondence from [name withheld] attesting to installation of approved insulation material at deck C above, Frame 257 IWO starboard side.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 17 November 2017
Resolved
0799 - Other (Fire fighting equipment) - Fire safety systems shall be maintained and ready for use. HI-FOG nozzle at frame 127 on C Deck overhead was not Ready for use due to missing an orifice. 74SOLAS(09) CH II-2/Reg 14.1.1
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 17 November 2017
Resolution: Deficiency Rectified