A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
18 February 2026
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8312305
27 January 2026
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8265529
13 November 2024
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8014629
4 September 2024
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7995268
13 November 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7824085
15 December 2022
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7609138
18 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579529
9 November 2021
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7347104
10 November 2020
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7088853
4 September 2019
Drydock Exam · COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6803706
19 November 2018
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6582017
13 November 2017
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6303541
6 February 2017
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6083352
16 November 2016
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6028365
24 February 2016
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5821023
16 November 2015
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5753273
2 October 2014
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4974291
23 August 2011
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4124979
19 October 2010
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3864807
5 October 2010
Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3859627
4 May 2009
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3552256
3 November 2008
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3353461
8 October 2008
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3290480
7 November 2007
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3087383
30 October 2006
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2810361
20 October 2005
Simplified Stability Test
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2518576
11 October 2005
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2511600
4 August 2004
Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2156500
22 July 2003
Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1854141
12 June 2002
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1629916
25 July 2001
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 45221
16 May 2001
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1410556
1 May 2001
Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1395730
11 April 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1062589
10 April 2001
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1062565
26 January 2000
Initial Construction-Excluding Oversight
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 814367
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 January 2026
Resolved
An adult life jacket must be provided for each person carried on board a vessel.(b) In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided.
Identified multiple adult and child sized life jackets in unsatisfactory condition due to deterioration of the internal flotation material. 5 Adult & 2 Child Sized life jackets are in satisfactory condition.
IAW the COI requirements, the vessel must carry a minimum of 31 Adult Sized & 4 Child Sized life jackets in satisfactory condition.
The vessel is limited to 03 passengers until rectified.
46CFR180.71
Action required: 705 - Other - as specified
Resolved 2 February 2026
Resolution: Vessel replaced deteriorated life jackets. the vessel now carries a minimum of 31 Adult Sized & 4 Child Sized life jackets in satisfactory condition.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 January 2026
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry:(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
The vessel is missing 02 distress signals.
Vessel is limited to DAYTIME operations until rectified.
46CFR180.68
Action required: 705 - Other - as specified
Resolved 2 February 2026
Resolution: The vessel has sufficient number of distress signals onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 January 2026
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:(1) Be buoyant;(2) Be of at least 18.3 meters (60 feet) in length;(3) Be non-kinking;(4) Have a diameter of at least 7.9 millimeters (5/16 inch);(5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light.
Ring life buoy life line is deteriorated and requires replacement.
46CFR180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 February 2026
Resolution: Ring life buoy life line was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 November 2024
Resolved
A vessel must carry one floating waterlight unless limited to daylight operations. Waterlight battery housing is cracked in several areas and not satisfactory condition.
46 CFR 180.70(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2024
Resolved 17 November 2024
Resolution: Waterlight was replaced with a new one.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 November 2024
Resolved
Seats used to determine the number of passengers permitted must be secured to the deck. Several seats have been replaced but not secured to the deck.
46 CFR 177.820(d)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2024
Resolved 17 November 2024
Resolution: Seating was secured to deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 December 2022
Resolved
Life ring reflective tape is not in a serviceable condition. Replace reflective tape or entire life ring to be serviceable.
46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2022
Resolved 21 December 2022
Resolution: SOLAS reflective tape was applied to life ring.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 December 2022
Resolved
First aid kit has several expired items. Replace expired items.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2022
Resolved 21 December 2022
Resolution: Expired items were replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 November 2016
Resolved
Navigation lights are inoperative.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 2 December 2016
Resolution: Repaired lights, full functional.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 October 2014
Resolved
Install emergency fuel shufoff valves directly to the port and starboard fuel tank connections.
Action required: 705 - Other - as specified
Resolved 16 October 2014
Resolution: Emergency fuel shutoff valves installed and pictures sent to DD Fort Myers.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 November 2007
Resolved
Replace expired items first aid kit.
Due 14 November 2007
Resolved 7 November 2007
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 30 October 2006
Resolved
Post additional lifejacket donning placards to be in plain view of all passengers.
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 6 November 2006
Resolution: Cleared
Fire Fighting › Means of Escape › Escape Route Signs
Issued 30 October 2006
Resolved
Label all emergency spaces in passenger areas.
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 6 November 2006
Resolution: Cleared
Communications › Radio Communications › VHF Radiotelephone
Issued 30 October 2006
Resolved
Provide evidence of FCC Safety Radio Telephony Certificate.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 6 November 2006
Resolution: Owner submitted request in writing to drop the full LBS route and to limit the vessel to not more than 1,000'' feet from shore.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 October 2005
Resolved
LOOSEN ALL PFD WAIST STRAPS TO MAKE READY TO DON.
Due 13 October 2005
Resolved 11 October 2005
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 11 October 2005
Resolved
PROVIDE A PROPER SOUND PRODUCING DEVICE (HORN) ONBOARD.
Due 13 October 2005
Resolved 11 October 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 October 2005
Resolved
UPDATE FIRST AID KIT MEDICINE AND PROVIDE SPLINT AS PER ISSUED INVENTORY LIST.
Due 13 October 2005
Resolved 11 October 2005
Engineering › Bilge Water Management System › Pump
Issued 11 October 2005
Resolved
PROVIDE A PORTABLE BILGE PUMP ONBOARD VESSEL.
Due 13 October 2005
Resolved 11 October 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 October 2004
Resolved
Affix line to lifering body with eye splice.
Action required: 705 - Other - as specified
Due 7 November 2004
Resolved 31 October 2004
Fire Fighting › Fire Bucket › Quantity
Issued 27 October 2004
Resolved
Provide three fire buckets with lanyard.
Action required: 705 - Other - as specified
Due 7 November 2004
Resolved 31 October 2004
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 27 October 2004
Resolved
Provide two flashlights
Action required: 705 - Other - as specified
Due 7 November 2004
Resolved 31 October 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 October 2004
Resolved
Provide retro tape on life ring IAW 46CFR185.604
Action required: 705 - Other - as specified
Due 7 November 2004
Resolved 31 October 2004
Engineering › Fuel Oil Service System › Valve, Control
Issued 27 October 2004
Resolved
Adjust port fuel shut off for full closure
Action required: 705 - Other - as specified
Due 7 November 2004
Resolved 27 October 2004
Resolution: Corrected on spot
Lifesaving › Hand Flares › Storage
Issued 4 August 2004
Resolved
Store distress signals in watertight, bright colored container and mark "distress signals".
Action required: 705 - Other - as specified
Due 7 November 2004
Resolved 31 October 2004
Lifesaving › Lifebuoys
Issued 22 July 2003
Resolved
Install waterlight and line to ring buoy. LEGACY COMPONENT DESC: Self-igniting Lights
Due 5 August 2003
Resolved 6 August 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 July 2003
Resolved
Install 1 missing adult PFD.
Due 5 August 2003
Resolved 6 August 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 July 2003
Resolved
Mark all PFDs with vessel name.
Due 5 August 2003
Resolved 6 August 2003
Operations/Management › Equipment Service/Testing
Issued 22 July 2003
Resolved
Replace expired items in first aid kit.
Due 5 August 2003
Resolved 6 August 2003
Lifesaving › Line-Throwing Appliances
Issued 12 June 2002
Resolved
Replace waterlight line with a 3-6 foot section of floatable line. LEGACY COMPONENT DESC: Lines
Due 24 June 2002
Resolved 6 August 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 June 2002
Resolved
Replace Type II extra child size PFDs with Type I. LEGACY COMPONENT DESC: Marking
Due 24 June 2002
Resolved 6 August 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 June 2002
Resolved
Replace missing adult PFD. LEGACY COMPONENT DESC: Quantity
Due 24 June 2002
Resolved 6 August 2003
Lifesaving
Issued 1 May 2001
Resolved
DEMONSTRATE PASSENGER SAFETY ORIENTATION TO COGNIZANT CG MARINE INSPECTOR.
Condition: Unknown
Due 1 June 2001
Resolved 1 May 2002
Lifesaving
Issued 1 May 2001
Resolved
PROVIDE LOCATION OF PASSENGER COUNT TO COGNIZANT OCMI.
Condition: Unknown
Due 1 June 2001
Resolved 1 May 2002
Navigation
Issued 1 May 2001
Resolved
PROVIDE CHARTS AND PUBLICATIONS FOR OPERATING AREA.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Documentation
Issued 1 May 2001
Resolved
PROVIDE PROOF THAT CREW ARE ENROLLED IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 1 June 2001
Resolved 1 May 2001
Documentation
Issued 1 May 2001
Resolved
PROVIDE PROOF OF OPERATORS LICENSE.
Condition: Unknown
Due 1 June 2001
Resolved 1 May 2001