JOHNNY RANGER is a 2008 tank ship. The Coast Guard has recorded 17 inspections since 2016, most recently in February 2026, along with 8 deficiencies and 2 operational controls.
Records from 2016 to 2026. Most recent: inspection, 25 February 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it13712 - Convention (Subpart B), Net Ton 50922 - Dead Weight, Metric Ton 62032 - Displacement, Metric Ton 30119 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
17 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 17
25 February 2026PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8315302
21 April 2025Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8116033
4 December 2024COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8041204
8 August 2023PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7757680
16 September 2022Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7560390
3 August 2022Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7523704
3 August 2022Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7523838
12 June 2022PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7469805
1 September 2021MARPOL Annex VI Survey · PSC B · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7301694
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 February 2026Resolved
"All lifesaving appliances and arrangements shall comply with the applicable requirements of the code. In addition to complying with the requirements of section 4.6 or 4.7 as applicable, a lifeboat with a self contained air support system shall be so arranged that, when proceeding with all entrances and openings closed, the air in the lifeboat remains safe and breathable and the engine runs normally for a period of not less than 10 mins." PSCO observed an air leak in the starboard side lifeboat air support system. Correct prior to carrying cargoes with a flashpoint less than 60 degrees C and require an air supported lifeboat.
Reference: 74SOLAS(2024) III/34
LSA Code V/4.8
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 March 2026
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 February 2026Resolved
A chemical tanker shall comply with the requirements of the International Bulk Chemical (IBC) code. Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products. PSCO observed worn conduit connecting to sensor for starboard tank cleaning pipe. Correct prior to carrying cargoes with a flash point less than 60 degrees Celsius.
Reference: 74 SOLAS (2024) VII/10
IBC Code 10.1.2.1
Action required: 705 - Other - as specified
Resolved 4 March 2026
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 February 2026Resolved
A chemical tanker shall comply with the requirements of the International Bulk Chemical (IBC) code. Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products. PSCO observed broken bolts on cargo tank 2 port/stbd alarm panels. Correct prior to carrying cargoes with a flash point less than 60 degrees Celsius.
Reference: 74 SOLAS (2024) VII/10
IBC Code 10.1.2.1
Action required: 705 - Other - as specified
Resolved 4 March 2026
Resolution: Received class report attesting to repairs.
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 25 February 2026Resolved
A chemical tanker shall comply with the requirements of the International Bulk Chemical (IBC) code.
Cargo tanks shall be fitted with a visual audible high level alarm which complies with 15.9.1 to 15.9.5 and which indicates when the liquid level in the cargo tank approaches the normal fuel condition. PSCO observed cargo tank 2 stbd high level and overfill alarms to sound at the same level. Correct prior to loading cargo tank in cargo tank 2 stbd.
Reference: 74SOLAS (2024) VII/10
IBC Code 15.19.6
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 March 2026
Resolution: Received class report attesting to repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 4 December 2024Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the code. In addition to complying with the requirements of section 4.6 or 4.7, as applicable, a lifeboat with a self contained air support system shall be so arranged that, when proceeding with all entrances and openings closed, the air in the lifeboat remains safe and breathable and the engine runs normally for a period of not less than 10 min. PSCO observed an air leak in the starboard side lifeboat air support system. Correct prior to carrying cargoes with a flash point less than 60 degrees Celsius and require an air supported lifeboat.
74 SOLAS (2020) III/34
LSA Code V/4.8
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2024
Resolved 5 December 2024
Resolution: Received and accepted class report from RINA stating the deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 4 December 2024Resolved
Plans and booklets shall be kept up to date; any alterations thereto shall be recorded as soon as practicable. PSCO observed multiple smoke and flame detectors in the vicinity of the auxiliary engines that were not accurately displayed on the fire control plan.
74 SOLAS (2020) II-2/15.2.4.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 December 2024
Resolution: Received and accepted class report from RINA stating the deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 July 2018Resolved
0720-Firefighting equipment-Fire Fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO discovered 07 failed hoses during operational test of emergency and main fire pump. Vessel received spare and replacement hoses during exam whihc were ordered (2) months prior. 74 SOLAS (14) II-2/14.2.1.2 - 10c
Action required: 10 - Deficiency Rectified
Resolved 11 July 2018
Resolution: At the time of exam vessel had recieved spare hoses which were ordered 2 months prior as a part of th vessel's annual fire main/hose test. Hoses were replaced at the time of exam.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 11 July 2017Resolved
0720-fire fighting equipment-fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSCO noted ships crew could not get the emergency fire pump to provide pressure while the vessel was in ballast condition. SOLAS 74(a) 2014 cons. II-2/14.1.1. 60a
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 11 July 2017
Resolved 12 July 2017
Resolution: Received, reviewed and accepted class report from RINA stating the deficiency was rectified. Upon inspection, class found self priming pump was not engaged, after adjustment, priming pump engaged and main pump was able to develop pressure immediately.