ARISTIDIS is a tank ship. The Coast Guard has recorded 7 inspections since 2017, most recently in January 2022, along with 2 deficiencies and 1 operational control.
Records from 2017 to 2022. Most recent: inspection, 7 January 2022.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it9925 - Convention (Subpart B), Net Ton 45628 - Displacement, Metric Ton 36680 - Dead Weight, Metric Ton 23270 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
7 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 7
7 January 2022COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7374133
5 March 2019ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6626618
20 February 2019Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6629242
28 February 2017Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6096445
24 February 2017Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6094195
24 February 2017Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6094396
17 February 2017ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6089395
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 24 February 2017Resolved
2515-The company should establish procedures for the implementation of corrective action, including measures to prevent reoccurrence. The company failed to address the need for an MGO chiller after notification twice from ship's crew resulting in loss of propulsion and grounding. ISM 9.2, 74SOLAS(09)IX/3.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2017
Resolution: RECEIVED SATSIFACTORY CLASS REPORT.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 24 February 2017Resolved
Due to ignored requests of the ship's crew to it's company to address issues to increase the ship's safety and ISM audit is recommended.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 February 2017
Resolution: RECEIVED SATISFACTORY ISM AUDIT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.