MAURY USCG vessel records Sign in
← All vessels

ARISTIDIS

ARISTIDIS is a tank ship. The Coast Guard has recorded 9 inspections since 2008, most recently in January 2022, along with 5 deficiencies and 1 operational control.

Records from 2008 to 2022. Most recent: inspection, 7 January 2022.

Built
Not recorded
Last inspected
7 January 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9327413 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
944885
Flag
MARSHALL ISLANDS
—
Maury page id
psix-944885

Inspections, by type

…with no type recorded2
Years with a record 4 calendar years (2008–2022)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9925 - Convention (Subpart B), Net Ton
45628 - Displacement, Metric Ton
36680 - Dead Weight, Metric Ton
23270 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

7 January 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7374133
5 March 2019 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6626618
20 February 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6629242
28 February 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6096445
24 February 2017 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6094195
24 February 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6094396
17 February 2017 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6089395
8 May 2008 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3201975
24 April 2008 ISPS I Exam · Ballast Water Examination · COC-CHEM Renew · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3190465

Deficiency record · 5

Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 24 February 2017 Resolved
2515-The company should establish procedures for the implementation of corrective action, including measures to prevent reoccurrence. The company failed to address the need for an MGO chiller after notification twice from ship's crew resulting in loss of propulsion and grounding. ISM 9.2, 74SOLAS(09)IX/3.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2017
Resolution: RECEIVED SATSIFACTORY CLASS REPORT.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 24 February 2017 Resolved
Due to ignored requests of the ship's crew to it's company to address issues to increase the ship's safety and ISM audit is recommended.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 February 2017
Resolution: RECEIVED SATISFACTORY ISM AUDIT.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 April 2008 Resolved
Noted that the pilot ladder was in poor condition. Vessel is to renew pilot ladder(s) prior to departure from St. Croix to the satisfaction of the USCG.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2008
Resolved 26 April 2008
Resolution: Renewed accomodation ladders. Port and Starboard.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 23 April 2008 Resolved
Vessel is to successfully conduct fire/abandon ship/emergency steering drills prior to departure from St. Croix.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2008
Resolved 25 April 2008
Resolution: Conducted drills, satisfactory.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 23 April 2008 Resolved
Noted that the vessel is not following the company's SMS requirements. Vessel is to provide evidence of compliance with document retention IAW the vessel isnpection and maintenance manual chapter 6 revision number 1. Records to be provided to RIO st. Croix prior to 8May2008.
Due 8 May 2008
Resolved 8 May 2008
Resolution: Def cleared

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.