Records from 2000 to 2025. Most recent: inspection, 2 September 2025.
Inspection history · 75
2 September 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8224868
28 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8101114
29 August 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7991445
5 September 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7784793
21 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7639284
31 August 2022
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7546002
20 May 2021
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7202109
3 May 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7187884
5 February 2020
Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6903039
15 December 2011
MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4208878
8 September 2010
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3827346
1 July 2009
Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3526468
15 January 2009
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3331480
31 July 2008
Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3285801
12 May 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3221026
10 April 2008
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3181763
10 April 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3181990
18 March 2008
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3167319
18 March 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3167394
1 March 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3157438
24 February 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3153669
16 February 2008
Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3148489
13 February 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3146996
9 January 2008
Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3127180
26 May 2007
Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2966669
23 May 2007
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2938003
4 October 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2791571
8 September 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2772808
31 July 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2731148
17 June 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3016328
10 May 2006
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2645963
10 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2582887
4 February 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2582970
5 January 2006
Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2563970
9 November 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2531523
29 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2345575
26 April 2005
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2342952
12 April 2005
Hull Examination · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2331958
4 April 2005
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2324311
14 February 2005
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2292236
10 February 2005
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2293913
4 February 2005
In-Service Inspection · MTSA Verification · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2280623
15 December 2004
Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2259908
1 December 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2251176
18 November 2004
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2243801
16 November 2004
In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2241805
8 June 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2091891
9 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1962500
4 November 2003
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1939618
20 August 2003
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1890669
4 August 2003
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1890665
19 July 2003
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1862904
12 May 2003
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1790050
18 April 2003
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1775957
11 December 2002
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1717143
24 September 2002
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1679737
18 July 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1657398
31 May 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1628642
22 May 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1619271
28 March 2002
Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1603051
1 March 2002
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1492691
28 November 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 772082
15 July 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 28151
29 March 2001
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1061357
24 January 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1465004
16 January 2001
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1401383
31 October 2000
Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1057118
4 October 2000
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 823369
3 October 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 12394
18 July 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 39711
20 May 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 179915
15 May 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 818610
13 April 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 167399
4 April 2000
Deficiency Check · Initial Certification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1468567
23 March 2000
Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1426348
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 29 August 2024
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency...the operator must secure each type III device in a manner which prevents discharge of treated or untreated sewage. MI observed overboard discharge for sewage not secured. Corrected on the spot.
33 CFR 159.7(c)
Action required: 10 - Deficiency Rectified
Resolved 29 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2023
Resolved
The owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the machinery. Port and Starboard MDE's displayed fault lights on local panel.
Action required: 10 - Deficiency Rectified
Due 6 September 2023
Resolved 6 September 2023
Resolution: Recieved tech report
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 September 2023
Resolved
Fixed gas fire extinguishing systems: A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Vessel's automatic shutdowns were disconnected and MI was unable to test shutdowns. 46 CFR 118.410(b)(10)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2023
Resolution: witnessed test
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 September 2023
Resolved
Except for continuously manned operating stations as allowed by paragraph (f) of this section, each accommodation space, control space, and service space must be fitted with the following systems:(2) A manual alarm system that meets the requirements in 46 CFR part 76. Vessel's manual call points located in the liquor store room and galley failed to operate on the alarm panel. 46 CFR 118.400(e)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2023
Resolution: Witnessed sat test.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 5 September 2023
Resolved
The OCMI determines the minimum number of mates required for the safe operation of inspected vessels. Vessel does not have a licensed mate onboard and does not have a senior deckhand designation letter as stated on the COI. Vessel is restricted to carrying 150 passengers. 46 CFR 15.810(a)
Action required: 705 - Other - as specified
Resolved 6 September 2023
Resolution: Vessel provided Senior Deck Hand letter
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 September 2023
Resolved
Electrical equipment exposed to the weather must be watertight. Vessels port side deck light is missing its cover and is no longer watertight. 46 CFR 120.210(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 October 2023
Resolution: Light was removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 September 2023
Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of §§ 118.400 and 118.500 must be designed, constructed, installed, and maintained in a manner acceptable to the Commandant. Vessels fire hose nozzle located on the bow was leaking. 46 CFR 118.120(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2023
Resolution: Replaced fire nozzle.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 February 2023
Resolved
Audio gauge steal underneath all keel coolers by next DDX.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 28 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2022
Resolved
Starboard generator shutdown inoperable.
Action required: 705 - Other - as specified
Due 7 September 2022
Resolved 9 September 2022
Resolution: Submitted sat tech report. See def documents for report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 August 2022
Resolved
First aid kit expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2022
Resolved 30 September 2022
Resolution: Vessl rep submitted sat photograph of new first aid kit aboard vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 August 2022
Resolved
Vessel Master unable to identify where on the vessel the fire zones listed on the fire detection panel where located. Post list denoting zones on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2022
Resolved 2 February 2023
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 December 2011
Resolved
Found multiple inoperative emergency lights. Replace/repair all emergency lighting
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2021
Resolution: complete
Communications › Radio Communications › EPIRB
Issued 15 December 2011
Resolved
EPIRB registration sticker missing. Provide registration sticker.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2021
Resolution: Route change, not required.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 December 2011
Resolved
Conduct drug and alcohol audit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2021
Resolution: complete
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 December 2011
Resolved
Conduct fire and man overboard drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2021
Resolution: complete
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 September 2010
Resolved
Conduct all underway drills and new to zone inspection prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2011
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 September 2010
Resolved
Conduct drug and alochol program audit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2011
Construction/Loadline › Structures › Ventilators
Issued 15 January 2009
Resolved
Repair or replace exterior shell vents (22 total) on port and starboard side by no later than 04 July 09 to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 4 July 2009
Resolved 1 July 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 September 2008
Resolved
Conduct Coast Guard drydock exam (hull and internal structural inspection) prior to operating with passengers or by 12JAN08. COI shows due date of 10/31/08.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2009
Resolved 15 January 2009
Resolution: Dry Dock exam conducted on this date.
Engineering › Generator (propulsion-electric) › Winding
Issued 26 February 2008
Resolved
Properly repair the #1 generator.
Action required: 705 - Other - as specified
Resolved 28 February 2008
Resolution: Tested the satisfactory operation of the #1 generator.
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 February 2008
Resolved
STBD engine fiber-glass exhaust cooler was found to be fractured and causing over-heating conditions to the STBD engine. Vsl to make sufficient repairs prior to operation.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 February 2008
Resolution: Witness satisfactory repair to the exhaust cooling piping. Tested the system to witness further overheating and leakage issues; none found.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 February 2008
Resolved
RENEW RAW WATER HOSE COUPLING ON STBD PROPULSION ENGINE @ SEA STRAINER INLET & DOUBLE CLAMP THE SAME.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2008
Resolution: Corrected.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 February 2008
Resolved
RENEW RAW WATER HOSE COUPLING ON STBD GENERATOR EXHAUST COOLING PIPE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2008
Resolution: Coupling was renewed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 February 2008
Resolved
MAKE TOILET DOORS IN MVZ ON MAIN DECK CLOSE & LATCH FREELY.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2008
Resolution: Corrected.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 8 February 2008
Resolved
GALLEY VENT DUCTS PORT SIDE MAKE PLATE CLOSE TIGHT.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2008
Resolution: Ducts were adjusted & closing tight.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 8 February 2008
Resolved
DEMONSTRATE VENTILATION DUCT IN A MVZ.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2008
Resolution: Duct in MVZ was working properly.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 8 February 2008
Resolved
DEMONSTRATE FIRE DETECTION SYSTEM. TEST ON BATTERY POWER.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2008
Resolution: Fire detection system was tested on battery power & found to be operating properly.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 8 February 2008
Resolved
SEAL ALL HOLES IN GALLEY BHD TO CREW AREA. REMOVE PLASTIC BHD ANCHORS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2008
Resolution: Holes were sealed.
Engineering › Bilge Water Management System › Not Operational
Issued 9 January 2008
Resolved
Prove properation of bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2008
Resolved 8 February 2008
Communications › Public Address System › Audio Distribution System Silencing
Issued 9 January 2008
Resolved
Public address system does not over-ride stereo system, prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2008
Resolved 8 February 2008
Resolution: Stereo was removed.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 9 January 2008
Resolved
Provide the following fire extinguishers: one AII for soft count room, one AII for 01 deck buffet, one AII or BII for galley and service the extinguisher on 02 deck IWO bar.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2008
Resolved 8 February 2008
Resolution: Fire extinguishers were installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 January 2008
Resolved
Renew ring buoy grab line on 02 deck aft.
Due 16 January 2008
Resolved 8 February 2008
Resolution: Corrected.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 January 2008
Resolved
Update safety plan for fire extinguishers.
Due 16 January 2008
Resolved 8 February 2008
Resolution: Plan was updated.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 January 2008
Resolved
Mount CO2 extinguisher in crew area.
Due 16 January 2008
Resolved 8 February 2008
Resolution: Extinguisher was mounted.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 9 January 2008
Resolved
Remove oily water from engine room bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2008
Resolved 8 February 2008
Resolution: Water was removed.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 9 January 2008
Resolved
Lable lifejacket stowage locations to reflect 572 total adult PFD's
Due 16 January 2008
Resolved 8 February 2008
Resolution: Corrected.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 9 January 2008
Resolved
Institute Ballast Water Management Plan.
Action required: 705 - Other - as specified
Due 8 February 2008
Resolved 28 March 2008
Resolution: Ballast water plan was implemented.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 26 May 2007
Resolved
Make permanent repairs to starboard dripless shaft seal.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2007
Resolved 13 June 2007
Resolution: new dripless shaft seal replaced in kind sat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 October 2006
Resolved
Repair salt water leaks on port/stbd SSDG & port MDE exhaust bond-strand piping and rubber flex-couplings in engine room.
Action required: 705 - Other - as specified
Resolved 4 August 2007
Resolution: cleared sat.
Construction/Loadline › Penetrations › Gasket
Issued 4 October 2006
Resolved
Repair or renew 4" wafer valve (or equivalent) for sewage overboard at sideshell in pumproom.
Action required: 705 - Other - as specified
Resolved 17 October 2006
Resolution: Examined installation of new valve. All sat.
Stability › Intact Righting Energy › General
Issued 4 October 2006
Resolved
Install loading marks IAW 46 CFR 122.602 (c) and (d).
Action required: 705 - Other - as specified
Resolved 18 October 2006
Resolution: Examined loading marks installed amidships. All sat.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 4 October 2006
Resolved
Renew port/stbd shafts and cutlass bearings NLT 16 Jan 2007 IAW agreementg documented in master's email dated 11 Oct 2006 to Sector SENE. All dive operations and checks by engineering shall be appropriately documented.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 4 August 2007
Resolution: Cleared sat.
Stability › Intact Righting Energy › General
Issued 4 October 2006
Resolved
Submit, or cause to be submitted, a letter to USCG Marine Safety Center documenting errors dicovered in stability data from which the minimum freeboards shown on the vessel's current Stability Letter was derived. Provide a copy of your submital to USCG Sector Southeastern New England (Prevention Dept.) no later than 24 Oct 2006.
Due 24 October 2006
Resolved 24 October 2006
Resolution: Received copy of submittal to MSC.
Documentation › Certificates/Documents › Stability Letter
Issued 4 October 2006
Resolved
Provide a copy of the new Stability Letter showing corrected freeboard values no later than 17 Dec 2007.
Due 17 December 2006
Resolved 31 October 2006
Resolution: Received copy of new stab ltr dated 31Oct2006.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 October 2006
Resolved
Remove 3 permanently-mounted slot machines obstructing interior side of tonnage opening on main deck/aft bulkhead of main casino area, or remeasure vessel for Regulatory Tonnage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2006
Resolution: Witnessed removal of slot machines and sighted clear opening IWO tonnage door.
Fire Fighting › Ventilation Systems › Ducts
Issued 5 January 2006
Resolved
Repair galley dishwasher ventilation exhaust ventilation duct damper.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2006
Resolved 5 January 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 January 2006
Resolved
Install sea rails on galley stove tops
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Fire Fighting › Structural - A Class Divisions › Doors
Issued 5 January 2006
Resolved
Repair gasket on #4 Fire screen door and verify proper operation and tight closure of door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Operations/Management › Drills/Instruction › Safety Orientation
Issued 5 January 2006
Resolved
Verify proper operation of all public address speakers throughout the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Fire Fighting › Combustible Materials › Insulation
Issued 5 January 2006
Resolved
Remove combustable storage items fom below the pilot house operating console,
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Communications › Alarms/Indicators › General Alarm
Issued 5 January 2006
Resolved
Demonstrate proper operation and verify the vessel general alarm and P.A. system operates while on emergency power.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 5 January 2006
Resolved
Install glass lamp covers on fixture in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 January 2006
Resolved
Seal holes in bulkhead In way of (IWO) main deck female head.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 January 2006
Resolved
Repair galley fire screen door to properly close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 January 2006
Resolved
Properly repair insulation on main engine room door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 January 2006
Resolved
Replace dry-rottet raw water cooling hoses on both ships service generators, starboard main diesel engine, and starboard A/C condensor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 5 January 2006
Resolved
Replace missing lagging on both exhaust pipes port and starboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Fire Fighting › Fire Pumps › Arrangement
Issued 5 January 2006
Resolved
De-rate main fire pump or provide documentation to show complinace at 40c ambient tempature.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 January 2006
Resolved
Properly label breaker boxes in game panels #1 and #2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 January 2006
Resolved
Conduct DAPI Audit within 14 days
Due 19 January 2006
Resolved 9 May 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 January 2006
Resolved
Repair or replace magnetic latch box portside forward on fire screen door #6.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Fire Fighting › Combustible Materials › Insulation
Issued 5 January 2006
Resolved
Remove combustable materials from thruster room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 9 May 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 April 2005
Resolved
Repair exhaust leak on starboard MDE exhaust manifold crossover piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2005
Resolved 25 August 2005
Resolution: Examined satisfactory repair.
Stability › Unintentional Flooding › General
Issued 12 April 2005
Resolved
Make permanent repairs to starboard main deck windows.
Due 23 May 2005
Resolved 25 August 2005
Resolution: Examined satisfactory replacement-in-kind window.
Construction/Loadline › Structures › Superstructure
Issued 8 April 2005
Resolved
Properly support new STBD window IAW 46CFR116.433.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 25 August 2005
Resolution: Examined satisfactory replacement-in-kind support structure for window.
Construction/Loadline › Structures › Superstructure
Issued 8 April 2005
Resolved
Provide material data sheet for new STBD window and ensure that it meets requirements outlined in 46CFR116.433.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 25 August 2005
Resolution: Examined satisfactory documntation from window manufacturer.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 April 2005
Resolved
Repair emergency light in galley. Light bulb is hanging by the electrical wires outside of the fixture.
Condition: Improper/Lack of Maintenance
Due 11 April 2005
Resolved 26 April 2005
Resolution: Examined repaired e-light. All sat.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 4 April 2005
Resolved
Provide a written Emergency Evacuation Plan (EEP) IAW 46CFR116.520 from refuge area to embarkation deck. No plan is onboard and crew has never had one.
Condition: Unknown
Due 30 June 2005
Resolved 25 August 2005
Resolution: Examined satisfactory evacuation plan showing primary and secondary egress routes from refuge areas to embarkation deck.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 4 April 2005
Resolved
Identify Stage Two on Evacuation Procedure Plan, and update station bill to fit crew to vessel. Stage One is outlined, but stage Two is not.
Condition: Unknown
Due 30 June 2005
Resolved 25 August 2005
Resolution: Examined satisfactory Stage Two evacuation procedures.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 4 April 2005
Resolved
Provide a public announcement system in both PORT and STBD stair tower. Until installed, provide crew members to assist passengers during emergencies. While underway with the engines running and the doors closed, you can not hear pipes over the PA system. During abandon ship drill, several crew members were stuck inside not realizing they had to abandon ship.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 9 May 2005
Resolution: Witnessed sat. test of public announcement system.
Construction/Loadline › Structures › Door
Issued 4 April 2005
Resolved
Provide the proper gaskets for FSD #2 & #3. No gasket was in #2 and in #3 they were missing approx 40% of material. Gasket material was rubber, and not the fire retardant material that was in all other FSD's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 9 May 2005
Resolution: Examined and found sat.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 April 2005
Resolved
Secure all engine room deck plates. While walking in E/R, the engineer fell through an aluminum deck plate because they are just sitting on the deck framing and not secured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 9 May 2005
Resolution: Deck plates examined and found secured sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 4 April 2005
Resolved
Prove proper operation of the FFFE system by a certified 3rd party with Coast Guard onboard; or provide a letter from owner attesting to the fact he will conduct test with local Coast Guard in Boston upon its' return on 13APR05. Because this is a COI, the FFFE system must be tested while CG is onboard IAW 46CFR115.810. (08APR05: RCVD A LETTER FROM OWNER)
Condition: Unknown
Due 11 April 2005
Resolved 26 April 2005
Resolution: Witnessed satisfactory tests of engine room CO2 and galley wet chemical fixed fire extinguishing systems.
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 4 April 2005
Resolved
Repair salt water leak on STBD muffler. Hose clamps were loose and the are had a build-up of dried salt. Area needs to be cleaned and new clamps installed.
Condition: Improper/Lack of Maintenance
Due 11 April 2005
Resolved 26 April 2005
Resolution: Examined and found exhaust leak repaired. All sat.
Communications › Radio Communications › EPIRB
Issued 4 April 2005
Resolved
Replace EPIRB battery by the expiration date of 30APR05.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 9 May 2005
Resolution: Examined EPIRB with new battery with expiration date of APR 2010 installed sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 4 April 2005
Resolved
Replace broken electrical covers on outlets IWO cash cage and main deck AFT. Covers have been broken and are not properly protecting wires and/or passengers.
Condition: Improper/Lack of Maintenance
Due 11 April 2005
Resolved 26 April 2005
Resolution: Examined renewed receptacle cover plates. All sat.
Electrical › Lighting (service) › Conductor
Issued 4 April 2005
Resolved
Provide pressure type wire connectors, or if twist-on type used as currently installed, provide proper installation per 46CFR120.340(i); (i.e. overhead light outside heads, main deck, FWD & under control station in wheelhouse.)
Condition: Improper Installation
Due 4 May 2005
Resolved 26 April 2005
Resolution: Examined new crimp-type connectors installed in place of wire nuts. All sat.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 4 April 2005
Resolved
Replace broken window, PORT side, 2nd deck AFT.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 25 August 2005
Resolution: Examined satisfactory replacement-in-kind window.
Electrical › Lighting (service) › Lighting Feeder
Issued 4 April 2005
Resolved
Seal wire penetration above FSD's 5, 8, & 9 with approved fire rating cauke. They had a 2 inch pipe running through a fire boundry with no means to stop flames from shooting through pipe into the other space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 9 May 2005
Resolution: Examined sat. firestop sealant in penetrations.
Construction/Loadline › Structures › Machinery Space Opening
Issued 4 April 2005
Resolved
Seal holes in BLKHD and OVHD between crew work space and AFT galley BLKHD with metal. Several 1/4 inch holes at FSD 9, and holes in OVHD, and PORT side of BLKHD using plastic anchors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 9 May 2005
Resolution: Examined holes sealed sat.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 4 April 2005
Resolved
Remove all plastic trash receptacles. They had plastic throughout vessel which increased fire load.
Condition: Unknown
Due 11 April 2005
Resolved 26 April 2005
Resolution: All plastic trash receptacles have been removed and replaced with metallic ones.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 4 April 2005
Resolved
Provide GFI Protection for deck 1, 2, & 3 bars.
Condition: Improper Installation
Due 4 May 2005
Resolved 26 April 2005
Resolution: Examined GFCI protection installed for receptacles in bars on decks 1, 2 & 3. All sat.
Electrical › Electric Supply System (service) › Cable
Issued 4 April 2005
Resolved
Rempve all electrical strips. Several electrical non-UL approved strips were noted throughout vessel. These can cause a fire while running of vessel generated 110 volt.
Condition: Placed in Improper Service
Due 4 May 2005
Resolved 26 April 2005
Resolution: All non-UL approved power strips removed from the vessel. All sat.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 4 April 2005
Resolved
Remove all stowage from bow thruster space entrance.
Condition: Improper/Lack of Maintenance
Due 11 April 2005
Resolved 26 April 2005
Resolution: Examined compartment and found nothing stowed in it. All sat.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 4 April 2005
Resolved
Provide copy of approved structural fire protection plan (SFP) and examine compliance with A-60 insulation around stairwell above ceilings in casino decks and prove enclosure around A/C unit on main deck FWD at bow thruster entrance meets BLKHD and OVHD fire control boundaries classification per 46CFR116.415(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 25 August 2005
Resolution: Cleared due to B-0 SPF boudary authorized IAW NVIC 7-97, Encl (1), Para. 6.18: fan room exemption.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 April 2005
Resolved
Prior to the carriage of passengers outside of MSO TAMMS zone, contact your local Marine Safety Office and conduct a New-To-Zone inspection. Vessel is leaving TAMMS AOR and heading to Boston on 11APR05.
Condition: Unknown
Due 11 April 2005
Resolved 26 April 2005
Resolution: New-to zone exam conducted this date.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 4 February 2005
Resolved
RENEW ALL DAMAGED FIRE DOOR GASKETS
Due 15 March 2005
Resolved 4 April 2005
Operations/Management › Drills/Instruction › Fire
Issued 4 February 2005
Resolved
ASSIGN SPECIFIC BILLET TO EACH OF THE 5 DOUBLE LEAF FIRE SCREEN DOORS AND PROVIDE TRAINING TO SPECIFICALLY LATCH FIRST LEAF WHEN DECK IS EVACUATED AND ENSURE 2ND LEAF IS CLOSED TIGHTLY PRIOR TO DEPARTURE FROM POSITION.
Due 11 March 2005
Resolved 4 April 2005
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 24 January 2005
Resolved
Prior to the carriage of passengers, provide a letter requesting inflatable LR's inspection date extension IAW 46CFR122.730.
Condition: Improper/Lack of Maintenance
Due 24 January 2005
Resolved 26 January 2005
Lifesaving › Buoyant Apparatus › Marking
Issued 24 January 2005
Resolved
Prior to the carriage of passengers, replace retro-reflective tape on all ring life buoys as needed.
Condition: Improper/Lack of Maintenance
Due 24 January 2005
Resolved 26 January 2005
Lifesaving › Buoyant Apparatus › Lifeline
Issued 24 January 2005
Resolved
Prior to the carriage of passengers, provide proper line on ring life buoys IAW 46CFR117.70(c).
Condition: Placed in Improper Service
Due 24 January 2005
Resolved 26 January 2005
Lifesaving › Hand Flares › Quantity
Issued 24 January 2005
Resolved
Prior to the carriage of passengers, provide 3 orange or 3 red day/night flares.
Condition: Improper/Lack of Maintenance
Due 24 January 2005
Resolved 26 January 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 January 2005
Resolved
Prior to the carriage of passengers, conduct drills.
Condition: Unknown
Due 24 January 2005
Resolved 26 January 2005
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 15 December 2004
Resolved
PROVE COMPLIANCE WITH DRUG TESTING REQUIREMENTS AS SET FORTH IN 46CFR16 AND 49CFR40 PRIOR TO CARRYING PASSENGERS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 December 2004
Resolved 16 December 2004
Resolution: CONDUCTED AUDITS OF DRUG TESTING PROGRAM ALL FOUND SAT.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 16 November 2004
Resolved
Provide valid hydro release for EPIRB IAW 46 CFR 117.64
Condition: Improper/Lack of Maintenance
Due 23 December 2004
Resolved 16 December 2004
Resolution: New hydro sited
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 16 November 2004
Resolved
Submit updated fire control and emergency evacuation plan for approval IAW 46 CFR 116.520,116.530. Make CG approved structural fire protection plan available to [name withheld].
Condition: Improper/Lack of Maintenance
Due 23 December 2004
Resolved 16 December 2004
Resolution: FCP approval ltr sited
Fire Fighting › Means of Escape › Doorways
Issued 16 November 2004
Resolved
Prove proper operation of fire doors located stbd side aft main deck IAW 46 CFR 116.435.
Condition: Improper/Lack of Maintenance
Due 23 December 2004
Resolved 16 December 2004
Resolution: Fire doors operated properly
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 16 November 2004
Resolved
Prove proper repair/ replace ducting and prove proper operation of fire damper at entrance of crew space port side IAW 46 CFR 116.405.
Condition: Improper/Lack of Maintenance
Due 23 December 2004
Resolved 16 December 2004
Resolution: Fire damper replaced, operational test conducted
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 16 November 2004
Resolved
Replace mufflers, port side engine room has been temp repaired in the past and both the port and stbd side steering gear room exhaust system shows signs of leaking. IAW 46 CFR 119.430
Condition: Improper/Lack of Maintenance
Due 23 December 2004
Resolved 16 December 2004
Resolution: Repairs made as per Manufactur Inst
Construction/Loadline › Penetrations › Gasket
Issued 16 November 2004
Resolved
Remove all sealing material from tonnage opening located at various points around vessel IAW 46 CFR 69.117.
Condition: Improper Installation
Due 23 December 2004
Resolved 26 January 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 16 November 2004
Resolved
Properly mount junction box and light fixture on 02 deck port side, properly secure the wire with approved banding material IAW 46 CFR 120.340.
Condition: Improper Installation
Due 23 December 2004
Resolved 16 December 2004
Resolution: All Junction boxs were mounted properly
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 8 June 2004
Resolved
Provide proper instructions for fire/bilge pump operation.
Action required: 705 - Other - as specified
Due 28 June 2004
Resolved 28 June 2004
Resolution: Provided proper instruction.
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 8 June 2004
Resolved
Prove proper testing of thermal detectors in engine room.
Action required: 705 - Other - as specified
Due 28 June 2004
Resolved 28 June 2004
Resolution: Tested as per manufactures instruction.
Fire Fighting › Means of Escape › Doorways
Issued 8 June 2004
Resolved
Prove proper operation of galley fire doors. (do not latch)
Action required: 705 - Other - as specified
Due 28 June 2004
Resolved 28 June 2004
Resolution: Tested sat.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 8 June 2004
Resolved
Label emergency escape hatches.
Action required: 705 - Other - as specified
Due 28 June 2004
Resolved 28 June 2004
Resolution: Labeled.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 June 2004
Resolved
Install proper sight glass guards for water and fuel tank.
Action required: 705 - Other - as specified
Due 28 June 2004
Resolved 28 June 2004
Resolution: Installed guards.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 8 June 2004
Resolved
Remove all combustible trash receptacles from the vessel.
Action required: 705 - Other - as specified
Due 28 June 2004
Resolved 28 June 2004
Resolution: Removed combustible trash receptacles.
Electrical › Electrical Distribution System (service) › Cable
Issued 8 June 2004
Resolved
Remove or repair extension cord from stage.
Action required: 705 - Other - as specified
Due 28 June 2004
Resolved 28 June 2004
Resolution: Repaired extension cord.
Engineering › Bilge Water Management System › Manifold
Issued 8 June 2004
Resolved
Test all remaining bilge suction points due to finding leak on port lazarette valve (could not pump out port lazarette)
Action required: 705 - Other - as specified
Due 28 June 2004
Resolved 28 June 2004
Resolution: Tested all remaining points, all sat.
Communications › Alarms/Indicators
Issued 12 May 2003
Resolved
Prove proper operation of Bilge high level alarm in Pump Room. Until alarm is repaired the space needs to be inspected for flooding every hour while underway. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 26 May 2003
Resolved 20 May 2003
Fire Fighting › Structural - A Class Divisions
Issued 22 May 2002
Resolved
Prove proper operation of stbd/aft fire screen door on 01 deck. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 705 - Other - as specified
Due 31 May 2002
Resolved 31 May 2002
Resolution: Witnessed satisfactory test of stbd/aft fire screen door on 01 deck.
Documentation › Certificates/Documents
Issued 22 May 2002
Resolved
Remove obstructions (3 slot machines) on interior side of tonnage opening on main deck/aft bulkhead of main casino area, or remeasue vessel for regulatory tonnage. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 August 2002
Resolved 17 December 2002
Resolution: REMOVED THREE SLOT MACHINES.
Lifesaving
Issued 24 January 2001
Resolved
STENCIL ALL PFD'S AND LIFE RING BOUYS WITH VESSEL NAME ON BOTH SIDES.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Accommodation/Occupational Safety
Issued 24 January 2001
Resolved
MARK ENTRANCES TO UPPER DECK WITH MAX PASSENGERS ALLOWED.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Engineering
Issued 24 January 2001
Resolved
REPLACE MATTING IN FRONT OF SWITCHBOARD WITH AN APPROVED ELECTRICAL MATTING.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Lifesaving
Issued 24 January 2001
Resolved
PROVIDE RESCUE BOAT OR SUBMIT PROPOSAL FOR MAN OVERBOARD RESCUE TO MSO TAMPA FOR APPROVAL.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Accommodation/Occupational Safety
Issued 24 January 2001
Resolved
PLACE PROPER HAILING PORT ON STERN OF VESSEL PER DOCUMENTATION REQT'S.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Lifesaving
Issued 24 January 2001
Resolved
UPDATE FIRST AID KIT IAW 46CFR160.041.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Fire Fighting
Issued 24 January 2001
Resolved
SERVICE B-II PORTABLE FIRE EXTINGUISHER AT STATION #7 AND BEHIND MAIN DECK BAR.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Accommodation/Occupational Safety
Issued 24 January 2001
Resolved
REPLACE ALL WASTE RECEPTICLES THROUGHOUT VESSEL WITH NON-FLAMMABLE TYPE.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Deck/Cargo
Issued 4 October 2000
Resolved
prior to carring passengers, make proper permanent repairs to vessels bow thruster.
Condition: Unknown
Due 4 November 2000
Resolved 29 November 2000
Lifesaving
Issued 4 April 2000
Resolved
MAKE VESSEL AVAILABLE AND DEMONSTRATE EMERGENCY DRILLS IN THE PRESENCE OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 April 2000
Resolved 17 April 2000
Unknown
Issued 4 April 2000
Resolved
COMPLETE WORKLISTS ISSUED 24MAR00 BY POMMS AND 4APR00 BY BOSMS.
Condition: Unknown
Due 13 April 2000
Resolved 17 April 2000