SPIL KARTIKA

SPIL KARTIKA is a 2008 freight ship. The Coast Guard has recorded 6 inspections since 2017, most recently in November 2025, along with 4 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2017 to 2025. Most recent: inspection, 9 November 2025.

Built
2008
Last inspected
9 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 November 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9353254
945286
Flag
PANAMA
Maury page id
psix-945286

Documentation record

Tonnage as PSIX records it42741 - Convention (Subpart B), Gross Ton
19338 - Convention (Subpart B), Net Ton
52773 - Dead Weight, Metric Ton
70038 - Displacement, Metric Ton
42800 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

9 November 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8265743
7 November 2025 Deficiency Check · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8265084
29 October 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8260694
21 May 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8140434
1 June 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6162284
19 April 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6128308

Deficiency record · 4

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 November 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed jacket water leak from M/E cylinder #1 74SOLAS(04) II-1 26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2025
Resolved 8 November 2025
Resolution: See attached class report
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 November 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leak from fuel oil control valve from boiler. 74SOLAS(09) II-2 1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2025
Resolution: See attached class report
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 7 November 2025 No resolution recorded
Every steam pipe and every fitting connected there to through which steam may pass shall be so designed constructed and installed as to with stand the maximum working stresses to which it may be subjected. PSCO observed excessive leakage from boiler freshwater control valve 74SOLAS(04) II-1 33.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 3 November 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: ... .2 Fire detection and fire alarm systems... Audible fire alarm was not operation during fire detection test in Fuel Oil Purifier room. 74 SOLAS (09) II-2 / 14.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2025
Resolution: Class report attesting to repairs attached in documents.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.