MAURY USCG vessel records
← All vessels

TM 750

TM 750 is a 2008 tank barge. The Coast Guard has recorded 23 inspections since 2008, most recently in December 2025, along with 7 deficiencies.

Records from 2008 to 2025. Most recent: inspection, 18 December 2025.

Built
2008
Last inspected
18 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

945477
Flag
UNITED STATES
Maury page id
psix-945477

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspections, by type

…with no type recorded1
Years with a record 17 calendar years (2008–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)192.0 ft × 42.0 ft × 10.0 ft
Registered tonnagegross 677 / net 677
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it677 - Simplified, Net Ton
677 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 23

18 December 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8285777
6 December 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8044361
27 November 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8035353
2 November 2023 Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7813422
12 December 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7607896
24 November 2021 Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7356886
25 May 2021 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7206490
19 October 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7079933
23 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7063765
5 November 2018 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6574482
10 September 2018 Examination of Repairs · Drydock Exam · Administrative Inspection · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6537004
5 October 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6306817
5 October 2016 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6016578
5 November 2015 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5774802
18 August 2014 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4958886
11 July 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4918852
19 June 2013 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4624353
17 October 2012 Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4466281
10 January 2012 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4223193
16 August 2011 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4117644
15 July 2010 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3796592
24 June 2009 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3512470
17 July 2008 Construction Oversight · Administrative Inspection · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3270702

Deficiency record · 7

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 November 2023 Resolved
cargo handling equipment shall be maintained by the tank vessel's personnel in accordance with the regulations in this sub-chapter including the following; (b) cargo pump relief valves shall be tested at least once each year.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2023
Resolved 6 November 2023
Resolution: P/V was tested and installed on vessel.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 November 2023 Resolved
cargo handling equipment shall be maintained by the tank vessel's personnel in accordance with the regulations in this sub-chapter including the following; (c) cargo pump pressure gauge shall be tested at least once a year for accuracy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2023
Resolved 6 November 2023
Resolution: Gauge was tested and installed on vessel.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 November 2023 Resolved
(3) Each pressure gauge must show pressure within 10 percent of the actual pressure; (f) the frequency of test and inspection required by this section must be; (3) for vessels, annually or as part of biennial and mid-period inspection. 33 CFR 170
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2023
Resolved 6 November 2023
Resolution: Gauge was tested and installed on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 November 2023 Resolved
Port and starboard side lights showing an unbroken light arc of the horizon of 112.5 degrees and so fixed as to show the light from right ahead to 22.5 degrees abaft the beam on its respective sides. special flashing light showing an arc of 180 degrees and more than 225 degrees and so fixed as to show the light from right ahead to abeam not more than 22.5 degrees abaft.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 17 November 2023
Resolution: Vessel secured light stands in proper position.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 November 2023 Resolved
Inspection for certification shall include an inspection of the machinery and equipment, and that it is in satisfactory condition and fit for the service for which it is intended.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 17 November 2023
Resolution: Vessel replaced exhaust cap on prime mover.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 November 2015 Resolved
Remove old lines on deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2015
Resolved 1 December 2015
Resolution: Old lines removed from deck
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 5 November 2015 Resolved
Flames screen on PV valve had holes in it
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2015
Resolved 6 November 2015
Resolution: Flame screen replaced

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.